shipboard & offshore power cableDIN 89158 / DIN 891600.6/1 kV (-40 to +90 °C)Polychloroprene / SHF1 Outer Sheath

MGG / MGH & MGCG / MGCH 0.6/1 kV DIN 89158 / 89160 HEPR Shipboard Power CableDIN 89158 / DIN 89160 — 0.6/1 kV — -40 to +90 °C Marine & Offshore Cable

MGG / MGH & MGCG / MGCH 0.6/1 kV (DIN 89158 / DIN 89160) HEPR-Insulated Copper-Braided & Unscreened Polychloroprene/SHF1 Shipboard Power Cable (DIN 89158 / DIN 89160, 0.6/1 kV, -40 to +90 °C, min. bend radius 6 × OD).

Flame-retardant
EMC screen
Oil-resistant
Approved
Order designation
MGG 3×16+1G16 mm²
Outer Ø ≈
22.4 mm
Net weight ≈
920 kg/km
Tensile rating ≈
3.8 kN
Core / stranding
IEC 60228 Class 2/5 Cu/SnCu
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
0.6/1 kV
Tested per DIN 89158 / DIN 89160
Operating temp.
−40…+90 °C
Continuous shipboard & offshore service
Min. bend radius
6 × OD
Marine tray, bulkhead & deck routing
Core / conductor
Stranded Copper
DIN VDE 0295 / IEC 60228 Class 2 strande
Outer protection
Polychloroprene
Heavy-duty polychloroprene (MGCG) or hal
Standard
DIN 89158 / DIN
DIN 89158 (MGCG/MGCH) & DIN 89160 (MGG/M

Typical values for this cable type, based on DIN 89158 (MGCG/MGCH) & DIN 89160 (MGG/MGH) / IEC 60092-353 — confirmed in the datasheet and quotation for your order.

Application fit

Is MGG / MGH & MGCG / MGCH 0.6/1 KV (DIN 89158) right for your machine?

MGG / MGH & MGCG / MGCH 0.6/1 kV (DIN 89158 / DIN 89160) HEPR-Insulated Copper-Braided & Unscreened Polychloroprene/SHF1 Shipboard Power Cable (DIN 89158 / DIN 89160, 0.6/1 kV, -40 to +90 °C, min. bend radius 6 × OD).

Offshore platform & shipboard deck trays

Suitable

Halogen-free SHF1/SHF2 or mud-resistant thermoset jacket withstands marine salt mist, oil and deck weathering.

Fixed installation

Suitable

Approved for bulkheads, cable trays, ladders and hull penetrations on commercial vessels and offshore units.

Drilling jumbo & rotary mast feed

Suitable

Metallic braid armour and cross-linked EPR/XLPE/XLPO insulation handle heavy mechanical and thermal duty.

Motor stator, traction & converter leads

Suitable

Stranded copper or tinned copper conductors terminate cleanly into marine switchboards, thrusters and transformers.

Energy chain / drag chain

Not suitable

Armoured shipboard and offshore feeder cable is not designed for high-cycle automation drag chains.

Use Drag-Chain Servo Cable
Typical machinesMarine & Offshore CableCommercial Vessels & Cruise ShipsOffshore Oil & Gas Platforms (FPSO)Jack-Up & Semi-Submersible Drilling RigsNaval Surface Vessels & Submarines

Construction

Layer by layer

Shown: MGG / MGH & MGCG / MGCH 0.6/1 KV (DIN 89158) (DIN 89158 (MGCG/MGCH) & DIN 89160 (MGG/MGH) / IEC 60092-353) featuring stranded copper conductors (3×50 mm²), hepr (3gi3) rubber insulation and polychloroprene / shf1 outer sheath (5-layer construction).

12345
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Stranded Copper Conductors (3×50 mm²)DIN VDE 0295 / IEC 60228 Class 2 stranded plain copper
2HEPR (3GI3) Rubber Insulation90 °C high-modulus ethylene-propylene rubber core insulation
3Extruded Inner CoveringElastomeric inner bedding sheath filling core interstices
4Copper Wire Braid Armour (DIN 89158)Bare copper wire braid screen and mechanical armouring
5Polychloroprene / SHF1 Outer SheathHeavy-duty polychloroprene (MGCG) or halogen-free (MGCH) jacket

MGG / MGH & MGCG / MGCH 0.6/1 KV (DIN 89158) — Standard Shipboard & Offshore Execution

Built to DIN 89158 (MGCG/MGCH) & DIN 89160 (MGG/MGH) / IEC 60092-353 with stranded copper conductors (3×50 mm²) and polychloroprene / shf1 outer sheath

MGG / MGH & MGCG / MGCH 0.6/1 KV (DIN 89158) — Custom Drum Length & Gland Kit

Available in custom continuous shipboard/offshore drum lengths or with marine EMC cable glands

MGG / MGH & MGCG / MGCH 0.6/1 KV (DIN 89158) — Class & Routine Test Certified

Supplied with EN 10204 3.1 routine dielectric, conductor resistance & flame/fire test report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on DIN 89158 (MGCG/MGCH) & DIN 89160 (MGG/MGH) / IEC 60092-353. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
0.6/1 kV (DIN 89158 (MGCG/MGCH) & DIN 89160 (MGG/MGH) / IEC 60092-353)
Core / conductor construction
Stranded Copper Conductors (3×50 mm²) — DIN VDE 0295 / IEC 60228 Class 2 stranded plain copper
Primary dielectric / buffering
HEPR (3GI3) Rubber Insulation — 90 °C high-modulus ethylene-propylene rubber core insulation

Thermal

Continuous operating temperature
−40…+90 °C (shipboard & offshore duty)
Short-circuit / peak thermal rating
Verified thermal stability per DIN 89158 (MGCG/MGCH) & DIN 89160 (MGG/MGH) / IEC 60092-353
Storage & transport temperature
−40…+80 °C on export wooden/steel drum

Mechanical

Outer protection / armouring
Polychloroprene / SHF1 Outer Sheath — Heavy-duty polychloroprene (MGCG) or halogen-free (MGCH) jacket
Minimum bending radius
6 × OD
Armour, screen & mechanical duty
Copper Wire Braid Armour (DIN 89158) — Bare copper wire braid screen and mechanical armouring

Resistance

Flame, fire & smoke performance
Qualified for marine flame-retardance and low-smoke zero-halogen / fire safety per DIN 89158 (MGCG/MGCH) & DIN 89160 (MGG/MGH) / IEC 60092-353
Oil, drilling mud & seawater resistance
Resistant to marine fuel/lube oils, salt mist and offshore fluids per DIN 89158 (MGCG/MGCH) & DIN 89160 (MGG/MGH) / IEC 60092-353
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
DIN 89158 (MGCG/MGCH) & DIN 89160 (MGG/MGH) / IEC 60092-353
Environmental & test standards
IEC 60228 / IEC 60332-3-22 / IEC 60754 / IEC 61034 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
MGG / MGH & MGCG / MGCH 0.6/1 KV (DIN 89158)
Sheath colour & metre marking
Continuous metre-marked black outer finish (Polychloroprene )
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard MGG / MGH & MGCG / MGCH 0.6/1 KV (DIN 89158) shipboard & offshore configurations

Manufactured to DIN 89158 (MGCG/MGCH) & DIN 89160 (MGG/MGH) / IEC 60092-353 for shipboard, offshore platform, drilling rig and marine applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Tensile rating
kN ≈
Min. bend R
mm
Enquiry
MGG / MGH & MGCG / MGCH 0.6/1 KV (DIN 89158) Construction Schedule (−40…+90 °C)
MGG 3×16+1G16 mm²3 × 16 + 1G16 mm² (4G16)IEC 60228 Class 2/5 Cu/SnCu22.49203.8135
MGG 3×35+1G16 mm²3 × 35 + 1G16 mm² (4G35)IEC 60228 Class 2/5 Cu/SnCu28.81,6907.4175
MGG 3×70+1G35 mm²3 × 70 + 1G35 mm² (4G70)IEC 60228 Class 2/5 Cu/SnCu38.23,26014.8230
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour grades and factory drum lengths available per DIN 89158 (MGCG/MGCH) & DIN 89160 (MGG/MGH) / IEC 60092-353.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, continuity & dimensional verification (DIN 89158 (MGCG/MGCH) & DIN 89160 (MGG/MGH) / IEC 60092-353)DC resistance at 20 °C / optical attenuation and outer diameter within DIN 89158 (MGCG/MGCH) & DIN 89160 (MGG/MGH) / IEC 60092-353 tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (DIN 89158 (MGCG/MGCH) & DIN 89160 (MGG/MGH) / IEC 60092-353)Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV ratingEvery manufactured drum length
Sample tests
Flame, fire integrity, oil/mud & mechanical qualification (DIN 89158 (MGCG/MGCH) & DIN 89160 (MGG/MGH) / IEC 60092-353)Verified flame/fire performance, fluid resistance and thermal stability across −40…+90 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

DIN 89158 / DIN 89160 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX MGG / MGH & MGCG / MGCH 0.6/1 KV (DIN 89158) DIN 89158 / DIN 89160 0.6/1 kV CE
Delivery form
Heavy-duty export fumigated wooden drums or steel marine reels
Standard lengths
500 m, 1,000 m or custom continuous shipboard/offshore lengths
MOQ
100 m (standard configurations) · 500 m (custom builds)
Lead time
2–5 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-25
Updated
2026-10-25

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define MGG / MGH & MGCG / MGCH 0.6/1 KV (DIN 89158) (MGG / MGH & MGCG / MGCH 0.6/1 kV DIN 89158 / 89160 HEPR Shipboard Power Cable)?
MGG / MGH & MGCG / MGCH 0.6/1 KV (DIN 89158) (MGG / MGH & MGCG / MGCH 0.6/1 kV DIN 89158 / 89160 HEPR Shipboard Power Cable) is manufactured in accordance with DIN 89158 (MGCG/MGCH) & DIN 89160 (MGG/MGH) / IEC 60092-353 for 0.6/1 kV service over -40 to +90 °C. Its 5-layer construction comprises stranded copper conductors (3×50 mm²), hepr (3gi3) rubber insulation and polychloroprene / shf1 outer sheath.
What is the minimum bending radius and operating temperature range for MGG / MGH & MGCG / MGCH 0.6/1 KV (DIN 89158)?
The minimum bending radius for MGG / MGH & MGCG / MGCH 0.6/1 KV (DIN 89158) is 6 × OD across its continuous operating temperature range of -40 to +90 °C, ensuring mechanical and dielectric reliability in shipboard and offshore service.
How are the concentric layers of MGG / MGH & MGCG / MGCH 0.6/1 KV (DIN 89158) arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Stranded Copper Conductors (3×50 mm²) — DIN VDE 0295 / IEC 60228 Class 2 stranded plain copper; (02) HEPR (3GI3) Rubber Insulation — 90 °C high-modulus ethylene-propylene rubber core insulation; (03) Extruded Inner Covering — Elastomeric inner bedding sheath filling core interstices; (04) Copper Wire Braid Armour (DIN 89158) — Bare copper wire braid screen and mechanical armouring; (05) Polychloroprene / SHF1 Outer Sheath — Heavy-duty polychloroprene (MGCG) or halogen-free (MGCH) jacket.
What factory test certificates are supplied with MGG / MGH & MGCG / MGCH 0.6/1 KV (DIN 89158)?
Every production drum of MGG / MGH & MGCG / MGCH 0.6/1 KV (DIN 89158) undergoes routine conductor resistance/continuity, high-voltage dielectric and dimensional testing per DIN 89158 (MGCG/MGCH) & DIN 89160 (MGG/MGH) / IEC 60092-353, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for MGG / MGH & MGCG / MGCH 0.6/1 KV (DIN 89158)

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

MGG / MGH & MGCG / MGCH 0.6/1 kV DIN 89158 / 89160 HEPR Shipboard Power Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote