MGG / MGH & MGCG / MGCH 0.6/1 kV (DIN 89158 / DIN 89160) HEPR-Insulated Copper-Braided & Unscreened Polychloroprene/SHF1 Shipboard Power Cable (DIN 89158 / DIN 89160, 0.6/1 kV, -40 to +90 °C, min. bend radius 6 × OD).
Typical values for this cable type, based on DIN 89158 (MGCG/MGCH) & DIN 89160 (MGG/MGH) / IEC 60092-353 — confirmed in the datasheet and quotation for your order.
Application fit
MGG / MGH & MGCG / MGCH 0.6/1 kV (DIN 89158 / DIN 89160) HEPR-Insulated Copper-Braided & Unscreened Polychloroprene/SHF1 Shipboard Power Cable (DIN 89158 / DIN 89160, 0.6/1 kV, -40 to +90 °C, min. bend radius 6 × OD).
Halogen-free SHF1/SHF2 or mud-resistant thermoset jacket withstands marine salt mist, oil and deck weathering.
Approved for bulkheads, cable trays, ladders and hull penetrations on commercial vessels and offshore units.
Metallic braid armour and cross-linked EPR/XLPE/XLPO insulation handle heavy mechanical and thermal duty.
Stranded copper or tinned copper conductors terminate cleanly into marine switchboards, thrusters and transformers.
Armoured shipboard and offshore feeder cable is not designed for high-cycle automation drag chains.
Use Drag-Chain Servo CableConstruction
Shown: MGG / MGH & MGCG / MGCH 0.6/1 KV (DIN 89158) (DIN 89158 (MGCG/MGCH) & DIN 89160 (MGG/MGH) / IEC 60092-353) featuring stranded copper conductors (3×50 mm²), hepr (3gi3) rubber insulation and polychloroprene / shf1 outer sheath (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Stranded Copper Conductors (3×50 mm²) | DIN VDE 0295 / IEC 60228 Class 2 stranded plain copper |
| 2 | HEPR (3GI3) Rubber Insulation | 90 °C high-modulus ethylene-propylene rubber core insulation |
| 3 | Extruded Inner Covering | Elastomeric inner bedding sheath filling core interstices |
| 4 | Copper Wire Braid Armour (DIN 89158) | Bare copper wire braid screen and mechanical armouring |
| 5 | Polychloroprene / SHF1 Outer Sheath | Heavy-duty polychloroprene (MGCG) or halogen-free (MGCH) jacket |
Built to DIN 89158 (MGCG/MGCH) & DIN 89160 (MGG/MGH) / IEC 60092-353 with stranded copper conductors (3×50 mm²) and polychloroprene / shf1 outer sheath
Available in custom continuous shipboard/offshore drum lengths or with marine EMC cable glands
Supplied with EN 10204 3.1 routine dielectric, conductor resistance & flame/fire test report
Technical data
Sizes
Manufactured to DIN 89158 (MGCG/MGCH) & DIN 89160 (MGG/MGH) / IEC 60092-353 for shipboard, offshore platform, drilling rig and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| MGG / MGH & MGCG / MGCH 0.6/1 KV (DIN 89158) Construction Schedule (−40…+90 °C) | |||||||
| MGG 3×16+1G16 mm² | 3 × 16 + 1G16 mm² (4G16) | IEC 60228 Class 2/5 Cu/SnCu | 22.4 | 920 | 3.8 | 135 | |
| MGG 3×35+1G16 mm² | 3 × 35 + 1G16 mm² (4G35) | IEC 60228 Class 2/5 Cu/SnCu | 28.8 | 1,690 | 7.4 | 175 | |
| MGG 3×70+1G35 mm² | 3 × 70 + 1G35 mm² (4G70) | IEC 60228 Class 2/5 Cu/SnCu | 38.2 | 3,260 | 14.8 | 230 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 3 × 16 + 1G16 mm² (4G16) | 1.15 | 0.6/1 kV (98 A) | −40…+90 °C |
| 3 × 35 + 1G16 mm² (4G35) | 0.52 | 0.6/1 kV (158 A) | −40…+90 °C |
| 3 × 70 + 1G35 mm² (4G70) | 0.27 | 0.6/1 kV (245 A) | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (DIN 89158 (MGCG/MGCH) & DIN 89160 (MGG/MGH) / IEC 60092-353) | DC resistance at 20 °C / optical attenuation and outer diameter within DIN 89158 (MGCG/MGCH) & DIN 89160 (MGG/MGH) / IEC 60092-353 tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (DIN 89158 (MGCG/MGCH) & DIN 89160 (MGG/MGH) / IEC 60092-353) | Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV rating | Every manufactured drum length |
| Sample tests | ||
| Flame, fire integrity, oil/mud & mechanical qualification (DIN 89158 (MGCG/MGCH) & DIN 89160 (MGG/MGH) / IEC 60092-353) | Verified flame/fire performance, fluid resistance and thermal stability across −40…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.