Offshore platform & shipboard deck trays
Halogen-free SHF1/SHF2 or mud-resistant thermoset jacket withstands marine salt mist, oil and deck weathering.
Product
RFOU P1/P8/P101 0.6/1(1.2) kV (Type P) EPR-Insulated TCWB-Armoured SHF2 Mud-Resistant Offshore Power & Control Cable (NEK TS 606 P1 / P8 / P101, 0.6/1 kV, -40 to +90 °C, min. bend radius 6 × OD).
Typical values for this cable type, based on NEK TS 606 Code P1/P8/P101 & IEC 60092-353 SHF2-MUD — confirmed in the datasheet and quotation for your order.
Application fit
RFOU P1/P8/P101 0.6/1(1.2) kV (Type P) EPR-Insulated TCWB-Armoured SHF2 Mud-Resistant Offshore Power & Control Cable (NEK TS 606 P1 / P8 / P101, 0.6/1 kV, -40 to +90 °C, min. bend radius 6 × OD).
Halogen-free SHF1/SHF2 or mud-resistant thermoset jacket withstands marine salt mist, oil and deck weathering.
Approved for bulkheads, cable trays, ladders and hull penetrations on commercial vessels and offshore units.
Metallic braid armour and cross-linked EPR/XLPE/XLPO insulation handle heavy mechanical and thermal duty.
Stranded copper or tinned copper conductors terminate cleanly into marine switchboards, thrusters and transformers.
Armoured shipboard and offshore feeder cable is not designed for high-cycle automation drag chains.
Use Drag-Chain Servo CableConstruction
Shown: RFOU P1/P8/P101 0.6/1 KV (NEK 606) (NEK TS 606 Code P1/P8/P101 & IEC 60092-353 SHF2-MUD) featuring tinned copper conductors (3×95 mm²), 90 °c epr core insulation (r) and shf2-mud outer sheath (u - p1/p8/p101) (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Tinned Copper Conductors (3×95 mm²) | IEC 60228 Class 2 / Class 5 stranded tinned annealed copper |
| 2 | 90 °C EPR Core Insulation (R) | Halogen-free ethylene-propylene rubber coded Black, Brown, Grey |
| 3 | Thermoset SHF2 Inner Sheath (F) | Extruded flame-retardant halogen-free elastomeric inner bedding |
| 4 | Tinned Copper Wire Braid (O) | High-coverage tinned copper wire braid armour (TCWB) |
| 5 | SHF2-MUD Outer Sheath (U - P1/P8/P101) | Cross-linked elastomer resistant to Calcium Bromide & Oil-Based Drilling Mud |
Built to NEK TS 606 Code P1/P8/P101 & IEC 60092-353 SHF2-MUD with tinned copper conductors (3×95 mm²) and shf2-mud outer sheath (u - p1/p8/p101)
Available in custom continuous shipboard/offshore drum lengths or with marine EMC cable glands
Supplied with EN 10204 3.1 routine dielectric, conductor resistance & flame/fire test report
Technical data
Sizes
Manufactured to NEK TS 606 Code P1/P8/P101 & IEC 60092-353 SHF2-MUD for shipboard, offshore platform, drilling rig and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| RFOU P1/P8/P101 0.6/1 KV (NEK 606) Construction Schedule (−40…+90 °C) | |||||||
| RFOU P1 3×16+1G16 mm² | 3 × 16 + 1G16 mm² (4G16) | IEC 60228 Class 2/5 Cu/SnCu | 22.4 | 920 | 3.8 | 135 | |
| RFOU P1 3×35+1G16 mm² | 3 × 35 + 1G16 mm² (4G35) | IEC 60228 Class 2/5 Cu/SnCu | 28.8 | 1,690 | 7.4 | 175 | |
| RFOU P1 3×70+1G35 mm² | 3 × 70 + 1G35 mm² (4G70) | IEC 60228 Class 2/5 Cu/SnCu | 38.2 | 3,260 | 14.8 | 230 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 3 × 16 + 1G16 mm² (4G16) | 1.15 | 0.6/1 kV (98 A) | −40…+90 °C |
| 3 × 35 + 1G16 mm² (4G35) | 0.52 | 0.6/1 kV (158 A) | −40…+90 °C |
| 3 × 70 + 1G35 mm² (4G70) | 0.27 | 0.6/1 kV (245 A) | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (NEK TS 606 Code P1/P8/P101 & IEC 60092-353 SHF2-MUD) | DC resistance at 20 °C / optical attenuation and outer diameter within NEK TS 606 Code P1/P8/P101 & IEC 60092-353 SHF2-MUD tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (NEK TS 606 Code P1/P8/P101 & IEC 60092-353 SHF2-MUD) | Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV rating | Every manufactured drum length |
| Sample tests | ||
| Flame, fire integrity, oil/mud & mechanical qualification (NEK TS 606 Code P1/P8/P101 & IEC 60092-353 SHF2-MUD) | Verified flame/fire performance, fluid resistance and thermal stability across −40…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.