Offshore platform & shipboard deck trays
Halogen-free SHF1/SHF2 or mud-resistant thermoset jacket withstands marine salt mist, oil and deck weathering.
Product
FA-DPYC / FA-TPYC / FA-MPYC & FR-FA Series 0.6/1 kV JIS C 3410 Shipboard Cable (JIS C 3410 / IEC 60331) engineered for 0.6/1 kV service across -40 to +90 °C (min. bend radius 6 × OD).
Typical values for this cable type, based on JIS C 3410:2018 / IEC 60332-3-22 Cat. A / IEC 60331-21 — confirmed in the datasheet and quotation for your order.
Application fit
FA-DPYC / FA-TPYC / FA-MPYC & FR-FA Series 0.6/1 kV JIS C 3410 Shipboard Cable (JIS C 3410 / IEC 60331) engineered for 0.6/1 kV service across -40 to +90 °C (min. bend radius 6 × OD).
Halogen-free SHF1/SHF2 or mud-resistant thermoset jacket withstands marine salt mist, oil and deck weathering.
Approved for bulkheads, cable trays, ladders and hull penetrations on commercial vessels and offshore units.
Metallic braid armour and cross-linked EPR/XLPE/XLPO insulation handle heavy mechanical and thermal duty.
Stranded copper or tinned copper conductors terminate cleanly into marine switchboards, thrusters and transformers.
Armoured shipboard and offshore feeder cable is not designed for high-cycle automation drag chains.
Use Drag-Chain Servo CableConstruction
Shown: FA-DPYC / FA-TPYC / FA-MPYC & FR-FA SERIES (JIS) (JIS C 3410:2018 / IEC 60332-3-22 Cat. A / IEC 60331-21) featuring tinned copper conductors (3×25 mm²), mica fire barrier + epr insulation (fr-fa) and cat.a flame-retardant outer sheath (fa) (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Tinned Copper Conductors (3×25 mm²) | JIS C 3410 stranded tinned annealed copper conductors |
| 2 | Mica Fire Barrier + EPR Insulation (FR-F | Mica tape (IEC 60331) + 90 °C EPR insulation (Black, White, Red) |
| 3 | Flame-Retardant Inner Bedding | Lapped glass/fire-retardant tape and extruded inner bedding |
| 4 | Galvanized Steel Wire Braid Armour (C) | Braided galvanized steel wire mechanical armour |
| 5 | Cat.A Flame-Retardant Outer Sheath (FA) | Outer jacket passing IEC 60332-3-22 Category A bunch burn test |
Built to JIS C 3410:2018 / IEC 60332-3-22 Cat. A / IEC 60331-21 with tinned copper conductors (3×25 mm²) and cat.a flame-retardant outer sheath (fa)
Available in custom continuous shipboard/offshore drum lengths or with marine EMC cable glands
Supplied with EN 10204 3.1 routine dielectric, conductor resistance & flame/fire test report
Technical data
Sizes
Manufactured to JIS C 3410:2018 / IEC 60332-3-22 Cat. A / IEC 60331-21 for shipboard, offshore platform, drilling rig and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| FA-DPYC / FA-TPYC / FA-MPYC & FR-FA SERIES (JIS) Construction Schedule (−40…+90 °C) | |||||||
| FA-DPYC 3×16+1G16 mm² | 3 × 16 + 1G16 mm² (4G16) | IEC 60228 Class 2/5 Cu/SnCu | 22.4 | 920 | 3.8 | 135 | |
| FA-DPYC 3×35+1G16 mm² | 3 × 35 + 1G16 mm² (4G35) | IEC 60228 Class 2/5 Cu/SnCu | 28.8 | 1,690 | 7.4 | 175 | |
| FA-DPYC 3×70+1G35 mm² | 3 × 70 + 1G35 mm² (4G70) | IEC 60228 Class 2/5 Cu/SnCu | 38.2 | 3,260 | 14.8 | 230 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 3 × 16 + 1G16 mm² (4G16) | 1.15 | 0.6/1 kV (98 A) | −40…+90 °C |
| 3 × 35 + 1G16 mm² (4G35) | 0.52 | 0.6/1 kV (158 A) | −40…+90 °C |
| 3 × 70 + 1G35 mm² (4G70) | 0.27 | 0.6/1 kV (245 A) | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (JIS C 3410:2018 / IEC 60332-3-22 Cat. A / IEC 60331-21) | DC resistance at 20 °C / optical attenuation and outer diameter within JIS C 3410:2018 / IEC 60332-3-22 Cat. A / IEC 60331-21 tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (JIS C 3410:2018 / IEC 60332-3-22 Cat. A / IEC 60331-21) | Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV rating | Every manufactured drum length |
| Sample tests | ||
| Flame, fire integrity, oil/mud & mechanical qualification (JIS C 3410:2018 / IEC 60332-3-22 Cat. A / IEC 60331-21) | Verified flame/fire performance, fluid resistance and thermal stability across −40…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents