FA-DPYC / FA-TPYC / FA-MPYC & FR-FA Series 0.6/1 kV JIS C 3410 Shipboard CableJIS C 3410 / IEC 60331 — 0.6/1 kV — -40 to +90 °C Marine & Offshore Cable

FA-DPYC / FA-TPYC / FA-MPYC & FR-FA Series 0.6/1 kV JIS C 3410 Shipboard Cable (JIS C 3410 / IEC 60331) engineered for 0.6/1 kV service across -40 to +90 °C (min. bend radius 6 × OD).

Flame-retardant
Ozone, UV & moisture
Oil-resistant
Approved
Order designation
FA-DPYC 3×16+1G16 mm²
Outer Ø ≈
22.4 mm
Net weight ≈
920 kg/km
Tensile rating ≈
3.8 kN
Core / stranding
IEC 60228 Class 2/5 Cu/SnCu
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
0.6/1 kV
Tested per JIS C 3410 / IEC 60331
Operating temp.
−40…+90 °C
Continuous shipboard & offshore service
Min. bend radius
6 × OD
Marine tray, bulkhead & deck routing
Core / conductor
Tinned Copper Co
JIS C 3410 stranded tinned annealed copp
Outer protection
Cat.A Flame-Reta
Outer jacket passing IEC 60332-3-22 Cate
Standard
JIS C 3410 / IEC
JIS C 3410:2018 / IEC 60332-3-22 Cat. A

Typical values for this cable type, based on JIS C 3410:2018 / IEC 60332-3-22 Cat. A / IEC 60331-21 — confirmed in the datasheet and quotation for your order.

Application fit

Is FA-DPYC / FA-TPYC / FA-MPYC & FR-FA SERIES (JIS) right for your machine?

FA-DPYC / FA-TPYC / FA-MPYC & FR-FA Series 0.6/1 kV JIS C 3410 Shipboard Cable (JIS C 3410 / IEC 60331) engineered for 0.6/1 kV service across -40 to +90 °C (min. bend radius 6 × OD).

Offshore platform & shipboard deck trays

Suitable

Halogen-free SHF1/SHF2 or mud-resistant thermoset jacket withstands marine salt mist, oil and deck weathering.

Fixed installation

Suitable

Approved for bulkheads, cable trays, ladders and hull penetrations on commercial vessels and offshore units.

Drilling jumbo & rotary mast feed

Suitable

Metallic braid armour and cross-linked EPR/XLPE/XLPO insulation handle heavy mechanical and thermal duty.

Motor stator, traction & converter leads

Suitable

Stranded copper or tinned copper conductors terminate cleanly into marine switchboards, thrusters and transformers.

Energy chain / drag chain

Not suitable

Armoured shipboard and offshore feeder cable is not designed for high-cycle automation drag chains.

Use Drag-Chain Servo Cable
Typical machinesBuilding & Fire SafetyCommercial Vessels & Cruise ShipsOffshore Oil & Gas Platforms (FPSO)Jack-Up & Semi-Submersible Drilling RigsNaval Surface Vessels & Submarines

Construction

Layer by layer

Shown: FA-DPYC / FA-TPYC / FA-MPYC & FR-FA SERIES (JIS) (JIS C 3410:2018 / IEC 60332-3-22 Cat. A / IEC 60331-21) featuring tinned copper conductors (3×25 mm²), mica fire barrier + epr insulation (fr-fa) and cat.a flame-retardant outer sheath (fa) (5-layer construction).

12345
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Tinned Copper Conductors (3×25 mm²)JIS C 3410 stranded tinned annealed copper conductors
2Mica Fire Barrier + EPR Insulation (FR-FMica tape (IEC 60331) + 90 °C EPR insulation (Black, White, Red)
3Flame-Retardant Inner BeddingLapped glass/fire-retardant tape and extruded inner bedding
4Galvanized Steel Wire Braid Armour (C)Braided galvanized steel wire mechanical armour
5Cat.A Flame-Retardant Outer Sheath (FA)Outer jacket passing IEC 60332-3-22 Category A bunch burn test

FA-DPYC / FA-TPYC / FA-MPYC & FR-FA SERIES (JIS) — Standard Shipboard & Offshore Execution

Built to JIS C 3410:2018 / IEC 60332-3-22 Cat. A / IEC 60331-21 with tinned copper conductors (3×25 mm²) and cat.a flame-retardant outer sheath (fa)

FA-DPYC / FA-TPYC / FA-MPYC & FR-FA SERIES (JIS) — Custom Drum Length & Gland Kit

Available in custom continuous shipboard/offshore drum lengths or with marine EMC cable glands

FA-DPYC / FA-TPYC / FA-MPYC & FR-FA SERIES (JIS) — Class & Routine Test Certified

Supplied with EN 10204 3.1 routine dielectric, conductor resistance & flame/fire test report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on JIS C 3410:2018 / IEC 60332-3-22 Cat. A / IEC 60331-21. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
0.6/1 kV (JIS C 3410:2018 / IEC 60332-3-22 Cat. A / IEC 60331-21)
Core / conductor construction
Tinned Copper Conductors (3×25 mm²) — JIS C 3410 stranded tinned annealed copper conductors
Primary dielectric / buffering
Mica Fire Barrier + EPR Insulation (FR-FA) — Mica tape (IEC 60331) + 90 °C EPR insulation (Black, White, Red)

Thermal

Continuous operating temperature
−40…+90 °C (shipboard & offshore duty)
Short-circuit / peak thermal rating
Verified thermal stability per JIS C 3410:2018 / IEC 60332-3-22 Cat. A / IEC 60331-21
Storage & transport temperature
−40…+80 °C on export wooden/steel drum

Mechanical

Outer protection / armouring
Cat.A Flame-Retardant Outer Sheath (FA) — Outer jacket passing IEC 60332-3-22 Category A bunch burn test
Minimum bending radius
6 × OD
Armour, screen & mechanical duty
Galvanized Steel Wire Braid Armour (C) — Braided galvanized steel wire mechanical armour

Resistance

Flame, fire & smoke performance
Qualified for marine flame-retardance and low-smoke zero-halogen / fire safety per JIS C 3410:2018 / IEC 60332-3-22 Cat. A / IEC 60331-21
Oil, drilling mud & seawater resistance
Resistant to marine fuel/lube oils, salt mist and offshore fluids per JIS C 3410:2018 / IEC 60332-3-22 Cat. A / IEC 60331-21
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
JIS C 3410:2018 / IEC 60332-3-22 Cat. A / IEC 60331-21
Environmental & test standards
IEC 60228 / IEC 60332-3-22 / IEC 60754 / IEC 61034 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
FA-DPYC / FA-TPYC / FA-MPYC & FR-FA SERIES (JIS)
Sheath colour & metre marking
Continuous metre-marked black outer finish (Cat.A Flame-Reta)
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard FA-DPYC / FA-TPYC / FA-MPYC & FR-FA SERIES (JIS) shipboard & offshore configurations

Manufactured to JIS C 3410:2018 / IEC 60332-3-22 Cat. A / IEC 60331-21 for shipboard, offshore platform, drilling rig and marine applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Tensile rating
kN ≈
Min. bend R
mm
Enquiry
FA-DPYC / FA-TPYC / FA-MPYC & FR-FA SERIES (JIS) Construction Schedule (−40…+90 °C)
FA-DPYC 3×16+1G16 mm²3 × 16 + 1G16 mm² (4G16)IEC 60228 Class 2/5 Cu/SnCu22.49203.8135
FA-DPYC 3×35+1G16 mm²3 × 35 + 1G16 mm² (4G35)IEC 60228 Class 2/5 Cu/SnCu28.81,6907.4175
FA-DPYC 3×70+1G35 mm²3 × 70 + 1G35 mm² (4G70)IEC 60228 Class 2/5 Cu/SnCu38.23,26014.8230
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour grades and factory drum lengths available per JIS C 3410:2018 / IEC 60332-3-22 Cat. A / IEC 60331-21.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, continuity & dimensional verification (JIS C 3410:2018 / IEC 60332-3-22 Cat. A / IEC 60331-21)DC resistance at 20 °C / optical attenuation and outer diameter within JIS C 3410:2018 / IEC 60332-3-22 Cat. A / IEC 60331-21 tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (JIS C 3410:2018 / IEC 60332-3-22 Cat. A / IEC 60331-21)Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV ratingEvery manufactured drum length
Sample tests
Flame, fire integrity, oil/mud & mechanical qualification (JIS C 3410:2018 / IEC 60332-3-22 Cat. A / IEC 60331-21)Verified flame/fire performance, fluid resistance and thermal stability across −40…+90 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

JIS C 3410 / IEC 60331 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX FA-DPYC / FA-TPYC / FA-MPYC & FR-FA SERIES (JIS) JIS C 3410 / IEC 60331 0.6/1 kV CE
Delivery form
Heavy-duty export fumigated wooden drums or steel marine reels
Standard lengths
500 m, 1,000 m or custom continuous shipboard/offshore lengths
MOQ
100 m (standard configurations) · 500 m (custom builds)
Lead time
2–5 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-25
Updated
2026-10-25

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define FA-DPYC / FA-TPYC / FA-MPYC & FR-FA SERIES (JIS) (FA-DPYC / FA-TPYC / FA-MPYC & FR-FA Series 0.6/1 kV JIS C 3410 Shipboard Cable)?
FA-DPYC / FA-TPYC / FA-MPYC & FR-FA SERIES (JIS) (FA-DPYC / FA-TPYC / FA-MPYC & FR-FA Series 0.6/1 kV JIS C 3410 Shipboard Cable) is manufactured in accordance with JIS C 3410:2018 / IEC 60332-3-22 Cat. A / IEC 60331-21 for 0.6/1 kV service over -40 to +90 °C. Its 5-layer construction comprises tinned copper conductors (3×25 mm²), mica fire barrier + epr insulation (fr-fa) and cat.a flame-retardant outer sheath (fa).
What is the minimum bending radius and operating temperature range for FA-DPYC / FA-TPYC / FA-MPYC & FR-FA SERIES (JIS)?
The minimum bending radius for FA-DPYC / FA-TPYC / FA-MPYC & FR-FA SERIES (JIS) is 6 × OD across its continuous operating temperature range of -40 to +90 °C, ensuring mechanical and dielectric reliability in shipboard and offshore service.
How are the concentric layers of FA-DPYC / FA-TPYC / FA-MPYC & FR-FA SERIES (JIS) arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Tinned Copper Conductors (3×25 mm²) — JIS C 3410 stranded tinned annealed copper conductors; (02) Mica Fire Barrier + EPR Insulation (FR-FA) — Mica tape (IEC 60331) + 90 °C EPR insulation (Black, White, Red); (03) Flame-Retardant Inner Bedding — Lapped glass/fire-retardant tape and extruded inner bedding; (04) Galvanized Steel Wire Braid Armour (C) — Braided galvanized steel wire mechanical armour; (05) Cat.A Flame-Retardant Outer Sheath (FA) — Outer jacket passing IEC 60332-3-22 Category A bunch burn test.
What factory test certificates are supplied with FA-DPYC / FA-TPYC / FA-MPYC & FR-FA SERIES (JIS)?
Every production drum of FA-DPYC / FA-TPYC / FA-MPYC & FR-FA SERIES (JIS) undergoes routine conductor resistance/continuity, high-voltage dielectric and dimensional testing per JIS C 3410:2018 / IEC 60332-3-22 Cat. A / IEC 60331-21, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for FA-DPYC / FA-TPYC / FA-MPYC & FR-FA SERIES (JIS)

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

FA-DPYC / FA-TPYC / FA-MPYC & FR-FA Series 0.6/1 kV JIS C 3410 Shipboard Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 