Contact
wind turbine tower, DLO & blade grounding power cableUL 2277 WTTC / UL 1277 TC-ER1,000 V WTTC / 600 V TC-ER (-40 to +-40 °C Oil & Sunlight-Resistant CPE/

UL Subject 2277 Type WTTC 1,000 V & UL 1277 TC-ER 600 V XHHW-2/RHW-2 CPE Wind Turbine Tray CableUL 2277 WTTC / UL 1277 TC-ER — 1,000 V WTTC / 600 V TC-ER — -40 to +90 °C Wind Turbine Cable

UL Subject 2277 Type WTTC 1,000 V & UL 1277 TC-ER 600 V XHHW-2/RHW-2 CPE Wind Turbine Tray Cable (UL 2277 WTTC / UL 1277 TC-ER) engineered for 1,000 V WTTC / 600 V TC-ER wind turbine service across -40 to +90 °C (min. bend radius 6 × OD).

Anti-torsion braid
Flame-retardant
Oil-resistant
Approved
Order designation
UL 2277 Type WTTC 1000V XHHW-2 1×95 / 4G25 Cu
Outer Ø ≈
21.6 mm
Net weight ≈
1,080 kg/km
Max. pulling ≈
14.2 kN
Core / stranding
IEC 60228 Class 5 Flexible Cu/SnCu
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
1,000 V WTTC / 6
Tested per UL 2277 WTTC / UL 1277 TC-ER
Operating temp.
−40…+90 °C
Cold-climate & nacelle wind service
Min. bend radius
6 × OD
Drip-loop, hub & tower routing
Core / conductor
Class K / Class
High-flexibility stranded copper conduct
Outer protection
-40 °C Oil & Sun
UL 2277 Wind Turbine Tray Cable outer sh
Standard
UL 2277 WTTC / U
UL Subject 2277 Type WTTC 1,000 V & UL 1

Typical values for this cable type, based on UL Subject 2277 Type WTTC 1,000 V & UL 1277 TC-ER XHHW-2/RHW-2 CPE Specification — confirmed in the datasheet and quotation for your order.

Application fit

Is UL 2277 Type WTTC 1000V XHHW-2/CPE right for your machine?

UL Subject 2277 Type WTTC 1,000 V & UL 1277 TC-ER 600 V XHHW-2/RHW-2 CPE Wind Turbine Tray Cable (UL 2277 WTTC / UL 1277 TC-ER) engineered for 1,000 V WTTC / 600 V TC-ER wind turbine service across -40 to +90 °C (min. bend radius 6 × OD).

Fixed installation

Suitable

Compacted Class 2 aluminum or Class 5/K copper conductors with XLPE/EPR/HEPR insulation install cleanly in vertical tower cleats and trays

Free-hanging vertical run

Suitable

Flexible DLO 2 kV, WTTC 1 kV and blade grounding builds absorb nacelle yaw loop torsion and rotor blade flexing down to −40 °C.

Switchgear & control cabinet wiring

Suitable

NSGAFOU 1.8/3 kV short-circuit-proof and UL WTTC/RHW-2 feeders wire directly into nacelle converter cabinets and tower base switchgear.

Offshore platform & shipboard deck trays

Suitable

Heavy-duty CPE, HM4/HFFR LSZH and 5GM3 polychloroprene jackets resist turbine hydraulic oil, condensation, salt spray and UV.

Energy chain / drag chain

Not suitable

Wind tower power feeders and large-cross-section DLO cables are not intended for high-cycle factory drag chains.

Use Drag-Chain Servo Cable
Typical machinesRenewable Energy & EV ChargingWind Turbine Tower Vertical Power Feeders (Cu & Al)North American UL 2277 WTTC & 2 kV DLO Wind TurbinesIEC 61400-24 Wind Blade Lightning Down-ConductorsNacelle Converter Busbars & Transformer Interconnects

Construction

Layer by layer

Shown: UL 2277 Type WTTC 1000V XHHW-2/CPE (UL Subject 2277 Type WTTC 1,000 V & UL 1277 TC-ER XHHW-2/RHW-2 CPE Specification) featuring class k / class 5 flexible copper (18 awg–500 kcmil), xhhw-2 (xlpe) / rhw-2 (epr) core insulation and -40 °c oil & sunlight-resistant cpe/pvc jacket (3-layer construction).

123
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Class K / Class 5 Flexible Copper (18 AWHigh-flexibility stranded copper conductors (2 to 37 cores)
2XHHW-2 (XLPE) / RHW-2 (EPR) Core Insulat90 °C wet/dry 1,000 V WTTC & 600 V TC-ER insulation
3-40 °C Oil & Sunlight-Resistant CPE/PVC UL 2277 Wind Turbine Tray Cable outer sheath

UL 2277 Type WTTC 1000V XHHW-2/CPE — Standard Wind Turbine Execution

Built to UL Subject 2277 Type WTTC 1,000 V & UL 1277 TC-ER XHHW-2/RHW-2 CPE Specification with class k / class 5 flexible copper (18 awg–500 kcmil) and -40 °c oil & sunlight-resistant cpe/pvc jacket

UL 2277 Type WTTC 1000V XHHW-2/CPE — Pre-Cut Tower / Drip-Loop Kit

Available on bulk export reels or pre-cut to turbine tower section and nacelle drip-loop lengths

UL 2277 Type WTTC 1000V XHHW-2/CPE — Cold Torsion & Routine Certified

Supplied with EN 10204 3.1 routine dielectric, conductor DC resistance & cold-torsion qualification report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on UL Subject 2277 Type WTTC 1,000 V & UL 1277 TC-ER XHHW-2/RHW-2 CPE Specification. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / operating system
1,000 V WTTC / 600 V TC-ER (UL Subject 2277 Type WTTC 1,000 V & UL 1277 TC-ER XHHW-2/RHW-2 CPE Specification)
Core / conductor construction
Class K / Class 5 Flexible Copper (18 AWG–500 kcmil) — High-flexibility stranded copper conductors (2 to 37 cores)
Primary dielectric / insulation
XHHW-2 (XLPE) / RHW-2 (EPR) Core Insulation — 90 °C wet/dry 1,000 V WTTC & 600 V TC-ER insulation

Thermal

Continuous operating temperature
−40…+90 °C (wind turbine nacelle, hub & tower duty)
Low-temperature torsion & cold bend
Verified cold-flex and torsion endurance across −40…+90 °C per UL Subject 2277 Type WTTC 1,000 V & UL 1277 TC-ER XHHW-2/RHW-2 CPE Specification
Storage & transport temperature
−40…+80 °C on export wooden/steel cable drum

Mechanical

Outer jacket / sheath protection
-40 °C Oil & Sunlight-Resistant CPE/PVC Jacket — UL 2277 Wind Turbine Tray Cable outer sheath
Minimum bending radius
6 × OD
Intermediate screen / separator / core layer
XHHW-2 (XLPE) / RHW-2 (EPR) Core Insulation — 90 °C wet/dry 1,000 V WTTC & 600 V TC-ER insulation

Resistance

Oil, grease, ozone & UV resistance
Resistant to wind turbine gearbox oil, hydraulic fluid, ozone and UV weathering per UL Subject 2277 Type WTTC 1,000 V & UL 1277 TC-ER XHHW-2/RHW-2 CPE Specification
Flame retardancy & smoke/halogen emission
Flame-retardant and environmental performance verified per UL Subject 2277 Type WTTC 1,000 V & UL 1277 TC-ER XHHW-2/RHW-2 CPE Specification
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
UL Subject 2277 Type WTTC 1,000 V & UL 1277 TC-ER XHHW-2/RHW-2 CPE Specification
Conductor & flame/test standards
IEC 60228 / IEC 60332-1-2 & -3 / UL 2277 WTTC / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
UL 2277 Type WTTC 1000V XHHW-2/CPE
Sheath colour & metre marking
Continuous metre-marked black outer finish (-40 °C Oil & Sun)
Customs tariff (HS)
8544.49 / 8544.60

Sizes

3 standard UL 2277 Type WTTC 1000V XHHW-2/CPE wind turbine configurations

Manufactured to UL Subject 2277 Type WTTC 1,000 V & UL 1277 TC-ER XHHW-2/RHW-2 CPE Specification for wind turbine yaw drip-loop, pitch control, tower power and converter applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Max. pulling
kN ≈
Min. bend R
mm
Enquiry
UL 2277 Type WTTC 1000V XHHW-2/CPE Construction Schedule (−40…+90 °C)
UL 2277 Type WTTC 1000V XHHW-2 1×95 / 4G25 Cu1 × 95 mm² (or 4G25 mm² / 3/0 AWG)IEC 60228 Class 5 Flexible Cu/SnCu21.61,08014.2110
UL 2277 Type WTTC 1000V XHHW-2 1×185 / 4G50 Cu1 × 185 mm² (or 4G50 mm² / 373 kcmil)IEC 60228 Class 5 Flexible Cu/SnCu27.81,96027.5140
UL 2277 Type WTTC 1000V XHHW-2 1×300 / 4G95 Cu1 × 300 mm² (or 1×535/777 kcmil)IEC 60228 Class 5 Flexible Cu/SnCu34.63,12045.0175
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom conductor cross-sections, core counts, pre-lugged tower kits and drum lengths available per UL Subject 2277 Type WTTC 1,000 V & UL 1277 TC-ER XHHW-2/RHW-2 CPE Specification.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor DC resistance & dimensional verification (UL Subject 2277 Type WTTC 1,000 V & UL 1277 TC-ER XHHW-2/RHW-2 CPE Specification)DC resistance at 20 °C and insulation/sheath wall thickness within UL Subject 2277 Type WTTC 1,000 V & UL 1277 TC-ER XHHW-2/RHW-2 CPE Specification limitsEvery manufactured drum length
AC high-voltage dielectric & insulation resistance test (UL Subject 2277 Type WTTC 1,000 V & UL 1277 TC-ER XHHW-2/RHW-2 CPE Specification)Zero dielectric breakdown and verified insulation resistance for 1,000 V WTTC / 600 V TC-ER ratingEvery manufactured drum length
Sample tests
Low-temperature drip-loop torsion, oil & flame qualification (UL Subject 2277 Type WTTC 1,000 V & UL 1277 TC-ER XHHW-2/RHW-2 CPE Specification)Verified cold torsion cycle endurance, oil resistance and flame retardancy across −40…+90 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

UL 2277 WTTC / UL 1277 TC-ER CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX UL 2277 Type WTTC 1000V XHHW-2/CPE UL 2277 WTTC / UL 1277 TC-ER 1,000 V WTTC / 600 V TC-ER CE
Delivery form
Heavy-duty export fumigated wooden drums, steel reels or pre-cut wind turbine tower & drip-loop kits
Standard lengths
500 m, 1,000 m or custom cut-to-length nacelle drip-loop and tower section sets
MOQ
100 m (standard configurations) · 300 m (custom wind builds)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-27
Updated
2026-10-27

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define UL 2277 Type WTTC 1000V XHHW-2/CPE (UL Subject 2277 Type WTTC 1,000 V & UL 1277 TC-ER 600 V XHHW-2/RHW-2 CPE Wind Turbine Tray Cable)?
UL 2277 Type WTTC 1000V XHHW-2/CPE (UL Subject 2277 Type WTTC 1,000 V & UL 1277 TC-ER 600 V XHHW-2/RHW-2 CPE Wind Turbine Tray Cable) is manufactured in accordance with UL Subject 2277 Type WTTC 1,000 V & UL 1277 TC-ER XHHW-2/RHW-2 CPE Specification for 1,000 V WTTC / 600 V TC-ER wind turbine service over -40 to +90 °C. Its 3-layer construction comprises class k / class 5 flexible copper (18 awg–500 kcmil), xhhw-2 (xlpe) / rhw-2 (epr) core insulation and -40 °c oil & sunlight-resistant cpe/pvc jacket.
What is the minimum bending radius and operating temperature range for UL 2277 Type WTTC 1000V XHHW-2/CPE?
The minimum bending radius for UL 2277 Type WTTC 1000V XHHW-2/CPE is 6 × OD across its continuous operating temperature range of -40 to +90 °C, ensuring mechanical torsion resistance and dielectric reliability in wind turbine nacelles, hubs and towers.
How are the concentric layers of UL 2277 Type WTTC 1000V XHHW-2/CPE arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Class K / Class 5 Flexible Copper (18 AWG–500 kcmil) — High-flexibility stranded copper conductors (2 to 37 cores); (02) XHHW-2 (XLPE) / RHW-2 (EPR) Core Insulation — 90 °C wet/dry 1,000 V WTTC & 600 V TC-ER insulation; (03) -40 °C Oil & Sunlight-Resistant CPE/PVC Jacket — UL 2277 Wind Turbine Tray Cable outer sheath.
What factory test certificates are supplied with UL 2277 Type WTTC 1000V XHHW-2/CPE?
Every production drum of UL 2277 Type WTTC 1000V XHHW-2/CPE undergoes routine conductor DC resistance, AC high-voltage dielectric and dimensional testing per UL Subject 2277 Type WTTC 1,000 V & UL 1277 TC-ER XHHW-2/RHW-2 CPE Specification, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for UL 2277 Type WTTC 1000V XHHW-2/CPE

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

UL 2277 Type WTTC 1000V XHHW-2/CPE UL Subject 2277 Type WTTC 1,000 V & UL 1277 TC-ER 600 V XHHW-2/RHW-2 CPE Wind Turbine Tray Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote