Offshore platform & shipboard deck trays
Halogen-free SHF1/SHF2 or mud-resistant thermoset jacket withstands marine salt mist, oil and deck weathering.
Product
TPHL, TPHL-CW/SB & SPBS2KV 600 V / 2,000 V IEEE 1580 Type P Single-Core Offshore Rig Traction & Feeder Cable (IEEE 1580 Type P / UL 1309) engineered for 600 V – 2,000 V service across -40 to +125 °C (min. bend radius 6 × OD).
Typical values for this cable type, based on IEEE 1580 Type P, UL 1309 & CSA C22.2 No. 245 Single-Core Traction Feeder — confirmed in the datasheet and quotation for your order.
Application fit
TPHL, TPHL-CW/SB & SPBS2KV 600 V / 2,000 V IEEE 1580 Type P Single-Core Offshore Rig Traction & Feeder Cable (IEEE 1580 Type P / UL 1309) engineered for 600 V – 2,000 V service across -40 to +125 °C (min. bend radius 6 × OD).
Halogen-free SHF1/SHF2 or mud-resistant thermoset jacket withstands marine salt mist, oil and deck weathering.
Approved for bulkheads, cable trays, ladders and hull penetrations on commercial vessels and offshore units.
Metallic braid armour and cross-linked EPR/XLPE/XLPO insulation handle heavy mechanical and thermal duty.
Stranded copper or tinned copper conductors terminate cleanly into marine switchboards, thrusters and transformers.
Armoured shipboard and offshore feeder cable is not designed for high-cycle automation drag chains.
Use Drag-Chain Servo CableConstruction
Shown: TPHL & TPHL-CW/SB / SPBS2KV (IEEE 1580 Type P, UL 1309 & CSA C22.2 No. 245 Single-Core Traction Feeder) featuring extra-flexible tinned copper (535 mcm), 125 °c xlpo type p insulation (600v/2000v) and arctic neoprene / xl-cpe mud jacket (4-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Extra-Flexible Tinned Copper (535 MCM) | Soft annealed tinned copper finely stranded for tight rig bends |
| 2 | 125 °C XLPO Type P Insulation (600V/2000 | Flame-retardant cross-linked polyolefin (IEEE 1580 Type P) |
| 3 | Bronze (SB) / Tinned Copper (CW) Braid | Non-magnetic bronze or tinned copper wire braid armour |
| 4 | Arctic Neoprene / XL-CPE Mud Jacket | Cold-bend (40 °C) and oil/drilling-mud resistant outer sheath |
Built to IEEE 1580 Type P, UL 1309 & CSA C22.2 No. 245 Single-Core Traction Feeder with extra-flexible tinned copper (535 mcm) and arctic neoprene / xl-cpe mud jacket
Available in custom continuous shipboard/offshore drum lengths or with marine EMC cable glands
Supplied with EN 10204 3.1 routine dielectric, conductor resistance & flame/fire test report
Technical data
Sizes
Manufactured to IEEE 1580 Type P, UL 1309 & CSA C22.2 No. 245 Single-Core Traction Feeder for shipboard, offshore platform, drilling rig and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| TPHL & TPHL-CW/SB / SPBS2KV Construction Schedule (−40…+125 °C) | |||||||
| TPHL 3×16+1G16 mm² | 3 × 16 + 1G16 mm² (4G16) | IEC 60228 Class 2/5 Cu/SnCu | 22.4 | 920 | 3.8 | 135 | |
| TPHL 3×35+1G16 mm² | 3 × 35 + 1G16 mm² (4G35) | IEC 60228 Class 2/5 Cu/SnCu | 28.8 | 1,690 | 7.4 | 175 | |
| TPHL 3×70+1G35 mm² | 3 × 70 + 1G35 mm² (4G70) | IEC 60228 Class 2/5 Cu/SnCu | 38.2 | 3,260 | 14.8 | 230 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 3 × 16 + 1G16 mm² (4G16) | 1.15 | 600 V – 2,000 V (98 A) | −40…+125 °C |
| 3 × 35 + 1G16 mm² (4G35) | 0.52 | 600 V – 2,000 V (158 A) | −40…+125 °C |
| 3 × 70 + 1G35 mm² (4G70) | 0.27 | 600 V – 2,000 V (245 A) | −40…+125 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (IEEE 1580 Type P, UL 1309 & CSA C22.2 No. 245 Single-Core Traction Feeder) | DC resistance at 20 °C / optical attenuation and outer diameter within IEEE 1580 Type P, UL 1309 & CSA C22.2 No. 245 Single-Core Traction Feeder tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (IEEE 1580 Type P, UL 1309 & CSA C22.2 No. 245 Single-Core Traction Feeder) | Zero dielectric breakdown and verified insulation resistance for 600 V – 2,000 V rating | Every manufactured drum length |
| Sample tests | ||
| Flame, fire integrity, oil/mud & mechanical qualification (IEEE 1580 Type P, UL 1309 & CSA C22.2 No. 245 Single-Core Traction Feeder) | Verified flame/fire performance, fluid resistance and thermal stability across −40…+125 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking