Contact
shipboard & offshore power cableIEEE 1580 Type P / UL 1309600 V – 2,000 V (-40 to +125 °C)Arctic Neoprene / XL-CPE Mud Jacket

TPHL, TPHL-CW/SB & SPBS2KV 600 V / 2,000 V IEEE 1580 Type P Single-Core Offshore Rig Traction & Feeder CableIEEE 1580 Type P / UL 1309 — 600 V – 2,000 V — -40 to +125 °C Marine & Offshore Cable

TPHL, TPHL-CW/SB & SPBS2KV 600 V / 2,000 V IEEE 1580 Type P Single-Core Offshore Rig Traction & Feeder Cable (IEEE 1580 Type P / UL 1309) engineered for 600 V – 2,000 V service across -40 to +125 °C (min. bend radius 6 × OD).

Flame-retardant
Water-resistant
Oil-resistant
Approved
Order designation
TPHL 3×16+1G16 mm²
Outer Ø ≈
22.4 mm
Net weight ≈
920 kg/km
Tensile rating ≈
3.8 kN
Core / stranding
IEC 60228 Class 2/5 Cu/SnCu
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
600 V – 2,000 V
Tested per IEEE 1580 Type P / UL 1309
Operating temp.
−40…+125 °C
Continuous shipboard & offshore service
Min. bend radius
6 × OD
Marine tray, bulkhead & deck routing
Core / conductor
Extra-Flexible T
Soft annealed tinned copper finely stran
Outer protection
Arctic Neoprene
Cold-bend (40 °C) and oil/drilling-mud r
Standard
IEEE 1580 Type P
IEEE 1580 Type P, UL 1309 & CSA C22.2 No

Typical values for this cable type, based on IEEE 1580 Type P, UL 1309 & CSA C22.2 No. 245 Single-Core Traction Feeder — confirmed in the datasheet and quotation for your order.

Application fit

Is TPHL & TPHL-CW/SB / SPBS2KV right for your machine?

TPHL, TPHL-CW/SB & SPBS2KV 600 V / 2,000 V IEEE 1580 Type P Single-Core Offshore Rig Traction & Feeder Cable (IEEE 1580 Type P / UL 1309) engineered for 600 V – 2,000 V service across -40 to +125 °C (min. bend radius 6 × OD).

Offshore platform & shipboard deck trays

Suitable

Halogen-free SHF1/SHF2 or mud-resistant thermoset jacket withstands marine salt mist, oil and deck weathering.

Fixed installation

Suitable

Approved for bulkheads, cable trays, ladders and hull penetrations on commercial vessels and offshore units.

Drilling jumbo & rotary mast feed

Suitable

Metallic braid armour and cross-linked EPR/XLPE/XLPO insulation handle heavy mechanical and thermal duty.

Motor stator, traction & converter leads

Suitable

Stranded copper or tinned copper conductors terminate cleanly into marine switchboards, thrusters and transformers.

Energy chain / drag chain

Not suitable

Armoured shipboard and offshore feeder cable is not designed for high-cycle automation drag chains.

Use Drag-Chain Servo Cable
Typical machinesMarine & Offshore CableCommercial Vessels & Cruise ShipsOffshore Oil & Gas Platforms (FPSO)Jack-Up & Semi-Submersible Drilling RigsNaval Surface Vessels & Submarines

Construction

Layer by layer

Shown: TPHL & TPHL-CW/SB / SPBS2KV (IEEE 1580 Type P, UL 1309 & CSA C22.2 No. 245 Single-Core Traction Feeder) featuring extra-flexible tinned copper (535 mcm), 125 °c xlpo type p insulation (600v/2000v) and arctic neoprene / xl-cpe mud jacket (4-layer construction).

1234
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Extra-Flexible Tinned Copper (535 MCM)Soft annealed tinned copper finely stranded for tight rig bends
2125 °C XLPO Type P Insulation (600V/2000Flame-retardant cross-linked polyolefin (IEEE 1580 Type P)
3Bronze (SB) / Tinned Copper (CW) BraidNon-magnetic bronze or tinned copper wire braid armour
4Arctic Neoprene / XL-CPE Mud JacketCold-bend (40 °C) and oil/drilling-mud resistant outer sheath

TPHL & TPHL-CW/SB / SPBS2KV — Standard Shipboard & Offshore Execution

Built to IEEE 1580 Type P, UL 1309 & CSA C22.2 No. 245 Single-Core Traction Feeder with extra-flexible tinned copper (535 mcm) and arctic neoprene / xl-cpe mud jacket

TPHL & TPHL-CW/SB / SPBS2KV — Custom Drum Length & Gland Kit

Available in custom continuous shipboard/offshore drum lengths or with marine EMC cable glands

TPHL & TPHL-CW/SB / SPBS2KV — Class & Routine Test Certified

Supplied with EN 10204 3.1 routine dielectric, conductor resistance & flame/fire test report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on IEEE 1580 Type P, UL 1309 & CSA C22.2 No. 245 Single-Core Traction Feeder. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
600 V – 2,000 V (IEEE 1580 Type P, UL 1309 & CSA C22.2 No. 245 Single-Core Traction Feeder)
Core / conductor construction
Extra-Flexible Tinned Copper (535 MCM) — Soft annealed tinned copper finely stranded for tight rig bends
Primary dielectric / buffering
125 °C XLPO Type P Insulation (600V/2000V) — Flame-retardant cross-linked polyolefin (IEEE 1580 Type P)

Thermal

Continuous operating temperature
−40…+125 °C (shipboard & offshore duty)
Short-circuit / peak thermal rating
Verified thermal stability per IEEE 1580 Type P, UL 1309 & CSA C22.2 No. 245 Single-Core Traction Feeder
Storage & transport temperature
−40…+80 °C on export wooden/steel drum

Mechanical

Outer protection / armouring
Arctic Neoprene / XL-CPE Mud Jacket — Cold-bend (40 °C) and oil/drilling-mud resistant outer sheath
Minimum bending radius
6 × OD
Armour, screen & mechanical duty
Bronze (SB) / Tinned Copper (CW) Braid — Non-magnetic bronze or tinned copper wire braid armour

Resistance

Flame, fire & smoke performance
Qualified for marine flame-retardance and low-smoke zero-halogen / fire safety per IEEE 1580 Type P, UL 1309 & CSA C22.2 No. 245 Single-Core Traction Feeder
Oil, drilling mud & seawater resistance
Resistant to marine fuel/lube oils, salt mist and offshore fluids per IEEE 1580 Type P, UL 1309 & CSA C22.2 No. 245 Single-Core Traction Feeder
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
IEEE 1580 Type P, UL 1309 & CSA C22.2 No. 245 Single-Core Traction Feeder
Environmental & test standards
IEC 60228 / IEC 60332-3-22 / IEC 60754 / IEC 61034 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
TPHL & TPHL-CW/SB / SPBS2KV
Sheath colour & metre marking
Continuous metre-marked black outer finish (Arctic Neoprene )
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard TPHL & TPHL-CW/SB / SPBS2KV shipboard & offshore configurations

Manufactured to IEEE 1580 Type P, UL 1309 & CSA C22.2 No. 245 Single-Core Traction Feeder for shipboard, offshore platform, drilling rig and marine applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Tensile rating
kN ≈
Min. bend R
mm
Enquiry
TPHL & TPHL-CW/SB / SPBS2KV Construction Schedule (−40…+125 °C)
TPHL 3×16+1G16 mm²3 × 16 + 1G16 mm² (4G16)IEC 60228 Class 2/5 Cu/SnCu22.49203.8135
TPHL 3×35+1G16 mm²3 × 35 + 1G16 mm² (4G35)IEC 60228 Class 2/5 Cu/SnCu28.81,6907.4175
TPHL 3×70+1G35 mm²3 × 70 + 1G35 mm² (4G70)IEC 60228 Class 2/5 Cu/SnCu38.23,26014.8230
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour grades and factory drum lengths available per IEEE 1580 Type P, UL 1309 & CSA C22.2 No. 245 Single-Core Traction Feeder.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, continuity & dimensional verification (IEEE 1580 Type P, UL 1309 & CSA C22.2 No. 245 Single-Core Traction Feeder)DC resistance at 20 °C / optical attenuation and outer diameter within IEEE 1580 Type P, UL 1309 & CSA C22.2 No. 245 Single-Core Traction Feeder tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (IEEE 1580 Type P, UL 1309 & CSA C22.2 No. 245 Single-Core Traction Feeder)Zero dielectric breakdown and verified insulation resistance for 600 V – 2,000 V ratingEvery manufactured drum length
Sample tests
Flame, fire integrity, oil/mud & mechanical qualification (IEEE 1580 Type P, UL 1309 & CSA C22.2 No. 245 Single-Core Traction Feeder)Verified flame/fire performance, fluid resistance and thermal stability across −40…+125 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

IEEE 1580 Type P / UL 1309 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX TPHL & TPHL-CW/SB / SPBS2KV IEEE 1580 Type P / UL 1309 600 V – 2,000 V CE
Delivery form
Heavy-duty export fumigated wooden drums or steel marine reels
Standard lengths
500 m, 1,000 m or custom continuous shipboard/offshore lengths
MOQ
100 m (standard configurations) · 500 m (custom builds)
Lead time
2–5 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-25
Updated
2026-10-25

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define TPHL & TPHL-CW/SB / SPBS2KV (TPHL, TPHL-CW/SB & SPBS2KV 600 V / 2,000 V IEEE 1580 Type P Single-Core Offshore Rig Traction & Feeder Cable)?
TPHL & TPHL-CW/SB / SPBS2KV (TPHL, TPHL-CW/SB & SPBS2KV 600 V / 2,000 V IEEE 1580 Type P Single-Core Offshore Rig Traction & Feeder Cable) is manufactured in accordance with IEEE 1580 Type P, UL 1309 & CSA C22.2 No. 245 Single-Core Traction Feeder for 600 V – 2,000 V service over -40 to +125 °C. Its 4-layer construction comprises extra-flexible tinned copper (535 mcm), 125 °c xlpo type p insulation (600v/2000v) and arctic neoprene / xl-cpe mud jacket.
What is the minimum bending radius and operating temperature range for TPHL & TPHL-CW/SB / SPBS2KV?
The minimum bending radius for TPHL & TPHL-CW/SB / SPBS2KV is 6 × OD across its continuous operating temperature range of -40 to +125 °C, ensuring mechanical and dielectric reliability in shipboard and offshore service.
How are the concentric layers of TPHL & TPHL-CW/SB / SPBS2KV arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Extra-Flexible Tinned Copper (535 MCM) — Soft annealed tinned copper finely stranded for tight rig bends; (02) 125 °C XLPO Type P Insulation (600V/2000V) — Flame-retardant cross-linked polyolefin (IEEE 1580 Type P); (03) Bronze (SB) / Tinned Copper (CW) Braid — Non-magnetic bronze or tinned copper wire braid armour; (04) Arctic Neoprene / XL-CPE Mud Jacket — Cold-bend (40 °C) and oil/drilling-mud resistant outer sheath.
What factory test certificates are supplied with TPHL & TPHL-CW/SB / SPBS2KV?
Every production drum of TPHL & TPHL-CW/SB / SPBS2KV undergoes routine conductor resistance/continuity, high-voltage dielectric and dimensional testing per IEEE 1580 Type P, UL 1309 & CSA C22.2 No. 245 Single-Core Traction Feeder, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for TPHL & TPHL-CW/SB / SPBS2KV

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

TPHL, TPHL-CW/SB & SPBS2KV 600 V / 2,000 V IEEE 1580 Type P Single-Core Offshore Rig Traction & Feeder Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote