Immersion & wet locations
Submarine armoured PE/PP builds and AD8 submersible jackets withstand seabed burial, wave catenaries and continuous seawater immersion.
Product
NEK 400-8-820 Havbruk Floating Fish Farm Cable featuring flexible stranded copper conductors (4 cores) and subsea / marine outer protective sheath (NEK 400-8-820 / NS 9415, 0.6/1 kV, -40 to +90 °C, min. bend radius 6 × OD).
Typical values for this cable type, based on NEK 400-8-820 & NS 9415 Norwegian Havbruk Floating Fish Farm Specification — confirmed in the datasheet and quotation for your order.
Application fit
NEK 400-8-820 Havbruk Floating Fish Farm Cable featuring flexible stranded copper conductors (4 cores) and subsea / marine outer protective sheath (NEK 400-8-820 / NS 9415, 0.6/1 kV, -40 to +90 °C, min. bend radius 6 × OD).
Submarine armoured PE/PP builds and AD8 submersible jackets withstand seabed burial, wave catenaries and continuous seawater immersion.
IEC 60502-1/-2 and IEC 60092-353 constructions install across shore landings, inter-cage subsea grids and shipboard cable trays.
Resistant to seawater, diesel oil, UV weathering and mechanical impact on floating aquaculture collars and port quaysides.
Dynamic aquaculture catenary and flexible shore-power builds absorb tidal rise, vessel heave and pontoon motion.
Submarine armoured feeders and shipboard power cables are not designed for high-cycle automated drag chains.
Use FD 855 P Drag-Chain CableConstruction
Shown: NEK 400-8-820 Havbruk Fish Farm (NEK 400-8-820 & NS 9415 Norwegian Havbruk Floating Fish Farm Specification) featuring flexible stranded copper conductors (4 cores), cross-linked elastomeric / polymer core insulation and subsea / marine outer protective sheath (4-layer construction).

| # | Layer | Material & reference |
|---|---|---|
| 1 | Flexible Stranded Copper Conductors (4 C | Class 5/ class 6 copper conductors |
| 2 | Cross-Linked Elastomeric / Polymer Core | Cross-linked polyethylene (xlpe) insulation |
| 3 | Water-Blocking Tape & Inner Bedding | Hydrostatic water-blocking filler and low-friction separator wrap |
| 4 | Subsea / Marine Outer Protective Sheath | Black low-smoke zero-halogen (SHF1 / SHF2 / LSZH) flame-retardant outer sheath |
Built to NEK 400-8-820 & NS 9415 Norwegian Havbruk Floating Fish Farm Specification with flexible stranded copper conductors (4 cores) and subsea / marine outer protective sheath
Available on continuous export winch drums or factory-terminated with subsea wet-mate / mechanical sockets
Supplied with EN 10204 3.1 routine dielectric, conductor/optical continuity & hydrostatic qualification report
Technical data
Sizes
Manufactured to NEK 400-8-820 & NS 9415 Norwegian Havbruk Floating Fish Farm Specification for subsea robotics, ROV umbilicals, marine aquaculture and offshore sensor applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Max. pulling kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| NEK 400-8-820 Havbruk Fish Farm Construction Schedule (−40…+90 °C) | |||||||
| NEK 400-8-820 Havbruk Fish Farm 4G4.0 mm² | 4G4.0 mm² (3×4.0 + 1G4.0 / 12 AWG) | IEC 60228 Class 5 Cu/SnCu | 14.2 | 340 | 3.2 | 85 | |
| NEK 400-8-820 Havbruk Fish Farm 4G16 mm² | 4G16 mm² (3×16 + 1G16 / 6 AWG) | IEC 60228 Class 5 Cu/SnCu | 21.4 | 840 | 9.6 | 130 | |
| NEK 400-8-820 Havbruk Fish Farm 3×50+1G25 mm² | 3 × 50 + 1G25 mm² (or 3×70+1G35) | IEC 60228 Class 5 Cu/SnCu | 32.8 | 2,240 | 26.5 | 195 | |
| Configuration | Max. DC R₂₀ Ω/km | Rating / Impedance / Load | Operating temp. |
|---|---|---|---|
| 4G4.0 mm² (3×4.0 + 1G4.0 / 12 AWG) | 4.95 | 0.6/1 kV (36 A Submersible) | −40…+90 °C |
| 4G16 mm² (3×16 + 1G16 / 6 AWG) | 1.21 | 0.6/1 kV (98 A Submersible) | −40…+90 °C |
| 3 × 50 + 1G25 mm² (or 3×70+1G35) | 0.39 | 0.6/1 kV (195 A Feeder) | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor DC resistance / OTDR optical & dimensional check (NEK 400-8-820 & NS 9415 Norwegian Havbruk Floating Fish Farm Specification) | DC resistance at 20 °C, optical attenuation and wall thickness within NEK 400-8-820 & NS 9415 Norwegian Havbruk Floating Fish Farm Specification limits | Every manufactured drum length |
| AC high-voltage dielectric & insulation resistance test (NEK 400-8-820 & NS 9415 Norwegian Havbruk Floating Fish Farm Specification) | Zero dielectric breakdown and verified wet insulation resistance for 0.6/1 kV rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, tensile load & seawater immersion qualification (NEK 400-8-820 & NS 9415 Norwegian Havbruk Floating Fish Farm Specification) | Verified hydrostatic pressure integrity, breaking load and flex endurance across −40…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.