High-temperature wires

Single-core hook-up and motor lead wires insulated with PTFE, FEP, PFA, ETFE, silicone rubber or mica-glass tape for furnaces, kilns, motors and aerospace harnesses.

How does the cable move?

Pick one or more duties — the list below updates.

28 high-temperature wires

Voltage
Standard
Sheath
Features

Fluoropolymer, polyimide and PEEK

PTFE, FEP, PFA, ETFE and ultra-high-vacuum polyimide and PEEK hook-up wires for chemical and thermal duty.

8 cables
301-KAP-RIB — cable cross-section
301-KAP-RIB301-KAP-RIB Polyimide Ultra-High-Vacuum Ribbon Cable
300/500 V
Control cabinet, furnace & kiln
IECFluoropolymer
300/500 V, IEC, Fluoropolymer sheathControl cabinet, furnace & kiln
301-KAPM-PAIR — cable cross-section
301-KAPM-PAIR301-KAPM-PAIR Polyimide UHV Screened Twisted-Pair Wire
300/500 V
Control cabinet, furnace & kiln
IECFluoropolymer
300/500 V, IEC, Fluoropolymer sheathControl cabinet, furnace & kiln
310-PEEKM-035 — cable cross-section
310-PEEKM-035310-PEEKM-035 PEEK-Insulated UHV Hook-Up Wire
300/500 V
Control cabinet, furnace & kiln
IECRubber
300/500 V, IEC, Rubber sheathControl cabinet, furnace & kiln
311-KAP / 301-KAPM — cable cross-section
311-KAP / 301-KAPM311-KAP / 301-KAPM Polyimide UHV Single-Core Wire
300/500 V
Control cabinet, furnace & kiln
IECSilicone
300/500 V, IEC, Silicone sheathControl cabinet, furnace & kiln
ETFE High Temperature Aerospace Wire — end cross section
ETFE High Temperature Aerospace WireETFE High Temperature Aerospace Wire
600 V
Control cabinet, furnace & kiln (limited), motor & traction leads
TEBAOFLEX designFluoropolymer
600 V, TEBAOFLEX design, Fluoropolymer sheathControl cabinet, furnace & kiln (limited), motor & traction leads
FEP High Temperature Hook-Up Wire — end cross section
FEP High Temperature Hook-Up WireFEP High Temperature Hook-Up Wire
300/500 V – 600 V
Control cabinet, furnace & kiln, motor & traction leads (limited)
UL / CSAFluoropolymer
300/500 V – 600 V, UL / CSA, Fluoropolymer sheathControl cabinet, furnace & kiln, motor & traction leads (limited)
PFA High Temperature Wire — end cross section
PFA High Temperature WirePFA High Temperature Wire
600 V
Control cabinet, furnace & kiln, submerged
UL / CSAFluoropolymer
600 V, UL / CSA, Fluoropolymer sheathControl cabinet, furnace & kiln, submerged
PTFE High Temperature Hook-Up Wire — end cross section
PTFE High Temperature Hook-Up WirePTFE High Temperature Hook-Up Wire
300/500 V – 600 V
Control cabinet, furnace & kiln, motor & traction leads (limited)
UL / CSAGlass braid
300/500 V – 600 V, UL / CSA, Glass braid sheathControl cabinet, furnace & kiln, motor & traction leads (limited)

Silicone and EVA heat-resistant

Single-core and screened multicore silicone rubber, fiberglass-braided and EVA heat-resistant wires up to +180 °C.

9 cables
H07G-K — cable cross-section
H07G-KH07G-K Flexible EVA Heat-Resistant Wire
300/500 V
Control cabinet, furnace & kiln
IECHalogen-free
300/500 V, IEC, Halogen-free sheathControl cabinet, furnace & kiln
H07G-R — cable cross-section
H07G-RH07G-R Stranded EVA Heat-Resistant Wire
300/500 V
Control cabinet, furnace & kiln
IECHalogen-free
300/500 V, IEC, Halogen-free sheathControl cabinet, furnace & kiln
H07G-U — cable cross-section
H07G-UH07G-U Solid-Conductor EVA Heat-Resistant Wire
300/500 V
Control cabinet, furnace & kiln
IECHalogen-free
300/500 V, IEC, Halogen-free sheathControl cabinet, furnace & kiln
SiFCuSi — cable cross-section
SiFCuSiSiFCuSi Copper-Braid Screened Silicone Cable
300/500 V
Control cabinet, furnace & kiln
IECSilicone
300/500 V, IEC, Silicone sheathControl cabinet, furnace & kiln
SiHFC — cable cross-section
SiHFCSiHFC Screened Multicore Silicone High-Temperature Cable
300/500 V
Control cabinet, furnace & kiln
IECSilicone
300/500 V, IEC, Silicone sheathControl cabinet, furnace & kiln
SRG-K — cable cross-section
SRG-KSRG-K Silicone Fiberglass-Braided Multicore Cable
300/500 V
Control cabinet, furnace & kiln
IECSilicone
300/500 V, IEC, Silicone sheathControl cabinet, furnace & kiln
Silicone Fiberglass Fixture Wire — end cross section
Silicone Fiberglass Fixture WireSilicone Fiberglass Fixture Wire
600 V
Control cabinet, furnace & kiln, motor & traction leads
UL / CSAGlass braid
600 V, UL / CSA, Glass braid sheathControl cabinet, furnace & kiln, motor & traction leads
Silicone Rubber Insulated High Temperature Wire — end cross section
Silicone Rubber Insulated High Temperature WireSilicone Rubber Insulated High Temperature Wire
300/500 V – 600 V
Control cabinet, furnace & kiln, motor & traction leads (limited)
UL / CSASilicone
300/500 V – 600 V, UL / CSA, Silicone sheathControl cabinet, furnace & kiln, motor & traction leads (limited)
Silicone Rubber Motor Lead Wire — end cross section
Silicone Rubber Motor Lead WireSilicone Rubber Motor Lead Wire
600 V – 1.0 kV
Control cabinet, furnace & kiln, motor & traction leads
UL / CSAGlass braid
600 V – 1.0 kV, UL / CSA, Glass braid sheathControl cabinet, furnace & kiln, motor & traction leads

Mica-glass, ceramic and HV ignition

Mica-tape and ceramic-fibre furnace wires up to +1000 °C and high-voltage burner and flare-stack ignition cables.

11 cables
CERAFIL CN8 — cable cross-section
CERAFIL CN8CERAFIL CN8 Ceramic-Fibre Ultra-High-Temperature Nickel Conductor
300/500 V
Control cabinet, furnace & kiln
IECRubber
300/500 V, IEC, Rubber sheathControl cabinet, furnace & kiln
FLAME ARREST LT — cable cross-section
FLAME ARREST LTFLAME ARREST LT Liquid-Tight High-Temperature Multicore Cable
300/500 V
Control cabinet, furnace & kiln
IECSilicone
300/500 V, IEC, Silicone sheathControl cabinet, furnace & kiln
Silicone High-Voltage Ignition Cable — cable cross-section
Silicone High-Voltage Ignition CableSilicone High-Voltage Ignition Cable
300/500 V
Control cabinet, furnace & kiln
IECSilicone
300/500 V, IEC, Silicone sheathControl cabinet, furnace & kiln
Thermo-Trex Flare Stack Cable — cable cross-section
Thermo-Trex Flare Stack CableThermo-Trex Flare Stack Cable
300/500 V
Control cabinet, furnace & kiln
IECRubber
300/500 V, IEC, Rubber sheathControl cabinet, furnace & kiln
Type MG Multi-Conductor — cable cross-section
Type MG Multi-ConductorType MG Multi-Conductor
300/500 V
Control cabinet, furnace & kiln
IECSilicone
300/500 V, IEC, Silicone sheathControl cabinet, furnace & kiln
UL AWM 3239 — cable cross-section
UL AWM 3239UL AWM 3239 High-Voltage Silicone Lead Wire
300/500 V
Control cabinet, furnace & kiln
IECSilicone
300/500 V, IEC, Silicone sheathControl cabinet, furnace & kiln
UL AWM 3257 — cable cross-section
UL AWM 3257UL AWM 3257 High-Voltage Silicone Ignition Wire
300/500 V
Control cabinet, furnace & kiln
IECSilicone
300/500 V, IEC, Silicone sheathControl cabinet, furnace & kiln
UL AWM 3304 / 3573 — cable cross-section
UL AWM 3304 / 3573UL AWM 3304 / 3573 Fiberglass-Reinforced Silicone Ignition Wire
300/500 V
Control cabinet, furnace & kiln
IECSilicone
300/500 V, IEC, Silicone sheathControl cabinet, furnace & kiln
UL AWM 5170 — cable cross-section
UL AWM 5170UL AWM 5170 450°C Mica-Tape and Glass-Braid High-Temperature
300/500 V
Control cabinet, furnace & kiln
IECSilicone
300/500 V, IEC, Silicone sheathControl cabinet, furnace & kiln
Wire-Wound Suppression Ignition Cable — cable cross-section
Wire-Wound Suppression Ignition CableWire-Wound Suppression Ignition Cable
300/500 V
Control cabinet, furnace & kiln
IECSilicone
300/500 V, IEC, Silicone sheathControl cabinet, furnace & kiln
Mica Glass High Temperature Wire — end cross section
Mica Glass High Temperature WireMica Glass High Temperature Wire
600 V
Control cabinet, furnace & kiln, motor & traction leads (limited)
UL / CSASilicone
600 V, UL / CSA, Silicone sheathControl cabinet, furnace & kiln, motor & traction leads (limited)

Choosing high-temperature wires

Four things decide most selections. Our engineers check the rest against your application.

Application and movement duty

  • Define whether the cable runs in a fixed tray, energy chain, festoon loop, reel or trailing route.
  • Match travel speed, bend radius and tensile load to the mechanical construction.
  • Select a support element or armour when the cable carries suspended weight or external crush loads.

Voltage class and core layout

  • Match the rated voltage U0/U to the supply system and earthing arrangement.
  • Specify phase cross-sections, protective earth, pilot cores or control pairs required by the machine.
  • Include copper braid, tape or semiconductive screens where EMC or electric-field control is needed.

Operating environment and sheath

  • Choose rubber, PUR, LSZH, PVC, fluoropolymer or silicone sheaths for the thermal and chemical exposure.
  • Verify oil, UV, water immersion, cold-flex or circuit-integrity ratings against site conditions.
  • Check outer diameter and gland compatibility at both terminations.

Standard and documentation

  • Confirm the governing standard family required by the project specification.
  • Verify conductor class, colour code or core numbering for the destination region.
  • Include operating duty and cable length in your enquiry so we can confirm the build.
Filter the range by standard

Questions buyers ask

Not covered here? Send your drawing and an engineer replies within 2 business hours.

Ask on WhatsApp
How do I select the right high-temperature wire from this range?

Start by filtering the list by movement duty, voltage band and sheath material. Compare how each high-temperature wire is constructed—conductor flexibility, insulation compound, screening and outer jacket—against your machine's bending radius, travel speed and ambient temperature. Open the product page or datasheet to check core counts, cross-sections and outer diameters before sending your enquiry.

When should high-temperature wires include metallic screening or armour?

Specify a copper braid or foil screen when high-temperature wires run near variable-frequency drives, carry analogue or fieldbus signals, or require medium-voltage electric-field control. Choose steel wire braid or armour when the installation faces rock fall, crushing loads or high pulling tension in roadways, decks or subsea routes.

Which outer sheath compound suits harsh industrial environments?

Heavy-duty rubber (PCP or CPE) provides balanced mechanical toughness, weather resistance and thermal stability. Polyurethane (PUR) resists cuts, abrasion and mineral oils on fast-moving chains, reels and trolleys. Halogen-free LSZH compounds reduce smoke and acid gas in tunnels, ships and enclosed buildings, while fluoropolymers and silicone handle extreme heat.

What details should I include in an RFQ for high-temperature wires?

Include the model designation or governing standard, rated voltage, number of cores and conductor cross-sections, along with the installation method, minimum bend radius, ambient temperature range and required delivery lengths. If you are replacing an existing cable on a machine, share the sheath marking so we can match the specification.

Engineering reference

Background on how high-temperature wires are built, rated and specified.

Read the full reference

TEBAOFLEX manufactures high temperature wire for industrial equipment, electrical appliances, heating systems, motors, generators and other applications where conventional wire insulation may not provide sufficient thermal resistance. Our high temperature wire range includes PTFE, FEP, PFA, ETFE, silicone rubber, fiberglass and mica insulated constructions for different operating temperatures, voltage levels, flexibility requirements and installation conditions.

The product range includes high temperature hook-up wire, equipment wire, fixture wire, aerospace wire and motor lead wire for OEM and industrial applications. Fluoropolymer insulated wires such as PTFE, FEP, PFA and ETFE are available for applications requiring compact dimensions, thermal resistance and demanding electrical performance, while silicone rubber constructions provide flexibility for machinery, heating equipment, appliances, motors and other high-temperature environments. Fiberglass and mica based constructions are also available for applications exposed to more severe thermal conditions.

Selecting the appropriate high temp wire depends on more than temperature alone. Rated voltage, conductor size, insulation material, flexibility, installation method, mechanical requirements and applicable standards should all be considered when specifying a wire construction.

If you already have a cable model, drawing or technical specification, send it to TEBAOFLEX for review and quotation. If the exact construction has not yet been determined, provide the operating temperature, voltage, conductor size, application and quantity, and our team can help identify a suitable high temperature wire for your project.

Compare cables

Voltage
Standard
Sheath
Features
Typical use

Highlighted rows differ between the selected cables.

Filters

Duty

Voltage

Standard

Sheath

Features