VFD inverter to AC motor screened feeder
Low-capacitance 600/1000 V XLPE/TPE construction and EMC screen suppress PWM switching noise between inverter and AC motor.
Product
VFD-SLIM 600/1000 V TC-ER cuts overall cable diameter up to 15% with precision-extruded XHHW-2 XLPE insulation, three symmetrical grounds, and dual foil/braid shielding for congested trays and conduits.
Typical values for this cable type, based on UL 1277 Type TC-ER · UL 2277 Type WTTC · CSA C22.2 No. 230 — confirmed in the datasheet and quotation for your order.
Application fit
VFD-SLIM 600/1000 V TC-ER cuts overall cable diameter up to 15% with precision-extruded XHHW-2 XLPE insulation, three symmetrical grounds, and dual foil/braid shielding for congested trays and conduits.
Low-capacitance 600/1000 V XLPE/TPE construction and EMC screen suppress PWM switching noise between inverter and AC motor.
Balanced 600/1000 V XLPE/TPE geometry cuts common-mode bearing currents and terminates cleanly inside motor junction boxes.
Screened 600/1000 V XLPE/TPE construction suppresses electromagnetic interference on shared industrial power and PLC signal trays.
Compact flame-retardant 600/1000 V XLPE/TPE geometry routes neatly through dense switchgear ducts, control cabinets, and DIN-rail terminals.
600/1000 V XLPE/TPE construction is built for stationary or light-flex runs, not continuous high-cycle drag-chain flexing.
Use (N)12YRDC11Y-J/O PUR600/1000 V XLPE/TPE build lacks anti-torsion tensile reinforcement for motorised drum reeling; select a dedicated reeling cable.
Use RG / RG-D (N)SHTOEU-JConstruction
Representative construction of VFD-SLIM 600/1000V TC-ER: tinned copper conductors, Reduced-wall UL 44 XHHW-2 thermoset XLPE, 100% Al/polyester foil + ≥ 85% tinned copper braid, and Black slim-profile oil- & UV-resistant PVC/TPE jacket.
| # | Layer | Material & reference |
|---|---|---|
| 1 | Conductor | ASTM B172 Class K flexible tinned annealed copperASTM B172 Class K / UL 1277 |
| 2 | Core insulation | Reduced-wall UL 44 XHHW-2 thermoset XLPEUL 1277 Type TC-ER |
| 3 | Core assembly & separator | Concentric cabled assembly with low-friction fleece or polyester binder tapeUL 1277 Type TC-ER |
| 4 | EMC metallic screen | 100% Al/polyester foil + ≥ 85% tinned copper braidEMC ≥ 85% / 100% foil |
| 5 | Outer sheath | Black slim-profile oil- & UV-resistant PVC/TPE jacketUL 1685 / FT4 Flame |
Three numbered black XLPE phase conductors with three symmetrically laid interstitial grounds under EMC shield.
Technical data
Sizes
| Cores × AWG/kcmil | Outer Ø ≈ mm | Max. R20 Ω/km | Copper index kg/km | Weight ≈ kg/km | Min. bend R 8×D mm |
|---|---|---|---|---|---|
| 3×14 AWG + 3×18 AWG | 10.4 | 9.070 | 109 | 210 | 83 |
| 3×12 AWG + 3×16 AWG | 11.4 | 5.710 | 159 | 288 | 91 |
| 3×10 AWG + 3×14 AWG | 12.8 | 3.590 | 237 | 410 | 102 |
| 3×8 AWG + 3×14 AWG | 15.9 | 2.260 | 331 | 588 | 127 |
| 3×6 AWG + 3×12 AWG | 18.1 | 1.420 | 507 | 862 | 145 |
| 3×4 AWG + 3×12 AWG | 21.8 | 0.892 | 734 | 1,248 | 174 |
| 3×2 AWG + 3×10 AWG | 26.2 | 0.561 | 1,140 | 1,905 | 210 |
| 3×1/0 AWG + 3×6 AWG | 30.6 | 0.353 | 1,919 | 3,065 | 245 |
| 3×2/0 AWG + 3×6 AWG | 33.1 | 0.280 | 2,308 | 3,666 | 265 |
| 3×4/0 AWG + 3×4 AWG | 40.1 | 0.176 | 3,637 | 5,701 | 321 |
| 3×350 kcmil + 3×2 AWG | 49.5 | 0.107 | 5,928 | 9,181 | 396 |
| 3×500 kcmil + 3×2 AWG | 56.9 | 0.075 | 8,037 | 12,392 | 455 |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| AC high-voltage dielectric test | 4 kV AC for 5 min without breakdown | Every manufactured drum |
| Conductor DC resistance test | Per ASTM B172 / B8 at 20 °C | Every drum length |
| Sample tests | ||
| EMC screen coverage & insulation check | Foil + TCWB continuity & wall thickness | Per production lot |
| Flame & environmental qualification | UL 1685 / FT4 Flame · UL Oil Res I/II | Type approval |
Marking & supply
Sheath marking