ICEA Standard Cables

US mining power and trailing cables to ICEA/NEMA, including ground-check types.

How does the cable move?

Pick one or more duties — the list below updates.

28 icea standard cables

Voltage
Standard
Sheath
Features

Trailing cables

Flexible power cables dragged behind mobile mining and material-handling machines.

6 cables
Type G-GC — end cross section
Type G-GCType G-GC 2 kV Portable Power and Mining Cable
2,000 V
Motorised reel (limited), multi-layer drum (limited), trailing, fixed (limited), submerged
ICEA / MSHAPE
2,000 V, ICEA / MSHA, PE sheathMotorised reel (limited), multi-layer drum (limited), trailing, fixed (limited), submerged
Type W — end cross section
Type WType W 2 kV Portable Power Cable
2,000 V
Motorised reel (limited), multi-layer drum (limited), festoon (limited), trailing, submerged
ICEA / MSHAPE
2,000 V, ICEA / MSHA, PE sheathMotorised reel (limited), multi-layer drum (limited), festoon (limited), trailing, submerged
Type SHD-GC — end cross section
Type SHD-GCType SHD-GC Shielded Mining Trailing Cable 2-25 kV
2 kV – 25 kV
Motorised reel, multi-layer drum (limited), trailing, fixed (limited), submerged
ICEA / MSHAPE
2 kV – 25 kV, ICEA / MSHA, PE sheathMotorised reel, multi-layer drum (limited), trailing, fixed (limited), submerged
Type SHD / SHD-CGC — end cross section
Type SHD / SHD-CGCSHD / SHD-CGC Shielded Underground Mining Trailing Cable
2 kV – 5 kV
Multi-layer drum, trailing, submerged, bretby handler
ICEA / MSHARubber
2 kV – 5 kV, ICEA / MSHA, Rubber sheathMulti-layer drum, trailing, submerged, bretby handler
Type G — end cross section
Type GType G Cable (ICEA/NEMA/MSHA)
2 kV
Motorised reel, multi-layer drum (limited), trailing, fixed (limited), submerged
ICEA / MSHAPVC
2 kV, ICEA / MSHA, PVC sheathMotorised reel, multi-layer drum (limited), trailing, fixed (limited), submerged
35-CHVU — cable cross-section
35-CHVU35-CHVU Mining-Machine Trailing Power Cable
300/500 V
Trailing, submerged
IECRubber
300/500 V, IEC, Rubber sheathTrailing, submerged

VFD cables

Screened motor cables for variable-frequency drives that contain drive noise.

1 cable
VFD Mining Power Cable — end cross section
VFD Mining Power CableVFD Mining Power Cable
2 kV
Trailing (limited), motor & traction leads, mine roadway, VFD motor feeder
ICEA / MSHAPE
2 kV, ICEA / MSHA, PE sheathTrailing (limited), motor & traction leads, mine roadway, VFD motor feeder

Hook-up wire & equipment cables

Equipment wires for panels, vehicles and rolling stock, from UL AWM to EN 50306.

4 cables
CCS HMWPE Tracer Wire — cable cross-section
CCS HMWPE Tracer WireCCS HMWPE Tracer Wire
300/500 V
Fixed, control cabinet
IECPE
300/500 V, IEC, PE sheathFixed, control cabinet
Copper HMWPE Tracer Wire — cable cross-section
Copper HMWPE Tracer WireCopper HMWPE Tracer Wire
300/500 V
Fixed, control cabinet
IECRubber
300/500 V, IEC, Rubber sheathFixed, control cabinet
UL AWM 3173 / SIS — cable cross-section
UL AWM 3173 / SISUL AWM 3173 / SIS Switchboard Wire
0.6/1 kV
Fixed, control cabinet
UL / CSAPVC
0.6/1 kV, UL / CSA, PVC sheathFixed, control cabinet
MIL-27500 — cable cross-section
MIL-27500MIL-27500 Aerospace Multicore Shielded Cable
0.6/1 kV
Fixed, control cabinet
UL / CSAFluoropolymer
0.6/1 kV, UL / CSA, Fluoropolymer sheathFixed, control cabinet

Control cables

Multicore control and signal cables for machine and system circuits.

2 cables
Drilling Mast Cable — end cross section
Drilling Mast CableDrilling Mast Cable
0.6/1 kV – 2 kV
Festoon, free-hanging, energy chain, drilling rig
ICEA / MSHAPE
0.6/1 kV – 2 kV, ICEA / MSHA, PE sheathFestoon, free-hanging, energy chain, drilling rig
Longwall Signal Cable — end cross section
Longwall Signal CableLongwall Signal Cable
50 V – 110 V
Trailing, bretby handler, mine roadway
ICEA / MSHAPUR
50 V – 110 V, ICEA / MSHA, PUR sheathTrailing, bretby handler, mine roadway

Power & connection cables

From 100 V welding leads to 45 kV feeders, with portable cords, EV charging and solar cables.

5 cables
Type MV-105 Flexible Single-Conductor — cable cross-section
Type MV-105 Flexible Single-ConductorType MV-105 Flexible Single-Conductor
3.6/6 kV – 12/20 kV
Fixed
UL / CSAHalogen-free
3.6/6 kV – 12/20 kV, UL / CSA, Halogen-free sheathFixed
Type MV-90 / MV-105 Distribution — cable cross-section
Type MV-90 / MV-105 DistributionType MV-90 / MV-105 Distribution MV-90/MV-105 Medium-Voltage
3.6/6 kV – 12/20 kV
Fixed
UL / CSAPVC
3.6/6 kV – 12/20 kV, UL / CSA, PVC sheathFixed
HMWPE Cathodic Protection Cable — cable cross-section
HMWPE Cathodic Protection CableHMWPE Cathodic Protection Cable
300/500 V
Trailing, fixed
IECPE
300/500 V, IEC, PE sheathTrailing, fixed
FAA L-824 Type B — cable cross-section
FAA L-824 Type BFAA L-824 Type B Airfield Lighting Cable
0.6/1 kV – 1.5 kV
Fixed
UL / CSAPE
0.6/1 kV – 1.5 kV, UL / CSA, PE sheathFixed
FAA L-824 Type C — cable cross-section
FAA L-824 Type CFAA L-824 Type C Airfield Lighting Cable
0.6/1 kV – 1.5 kV
Fixed
UL / CSAPE
0.6/1 kV – 1.5 kV, UL / CSA, PE sheathFixed

Rubber cables

Rubber-insulated, rubber-sheathed cables for mobile and heavy-duty service.

10 cables
SOOW — end cross section
SOOWSOOW 600 V and SJOOW 300 V Flexible Portable Cord
600 V
Motorised reel (limited), festoon, trailing, fixed (limited), submerged
ICEA / MSHARubber
600 V, ICEA / MSHA, Rubber sheathMotorised reel (limited), festoon, trailing, fixed (limited), submerged
DLO 2kV — end cross section
DLO 2kVDLO Cable – 2 kV Heavy-Duty Flexible Power Cable
2000 V
Fixed, control cabinet, motor & traction leads, drilling rig
ICEA / MSHAPE
2000 V, ICEA / MSHA, PE sheathFixed, control cabinet, motor & traction leads, drilling rig
Type W Magnet Crane — end cross section
Type W Magnet CraneMagnet Crane Cable — Type W 2 kV, Aramid-Reinforced
2000 V
Motorised reel, festoon, trailing, vertical / spreader, submerged
ICEA / MSHARubber
2000 V, ICEA / MSHA, Rubber sheathMotorised reel, festoon, trailing, vertical / spreader, submerged
Type MP-GC — end cross section
Type MP-GCType MP-GC Mine Power Feeder Cable
5 kV – 35 kV
Free-hanging, fixed, mine roadway
ICEA / MSHAPVC
5 kV – 35 kV, ICEA / MSHA, PVC sheathFree-hanging, fixed, mine roadway
Underground Lighting Cable — end cross section
Underground Lighting CableUnderground Lighting Cable
110 V – 600 V
Fixed, submerged, mine roadway
ICEA / MSHAPUR
110 V – 600 V, ICEA / MSHA, PUR sheathFixed, submerged, mine roadway
2XS / 2XSO — cable cross-section
2XS / 2XSO2XS / 2XSO Cross-Linked Elastomer Flexible Cable
300/500 V
Motorised reel, trailing
IECRubber
300/500 V, IEC, Rubber sheathMotorised reel, trailing
2XSAW / 2XSAOW / 2XSW / 2XSOW — cable cross-section
2XSAW / 2XSAOW / 2XSW / 2XSOW2XSAW / 2XSAOW / 2XSW / 2XSOW Heavy-Duty Portable Cord
300/500 V
Motorised reel, trailing
IECPE
300/500 V, IEC, PE sheathMotorised reel, trailing
3XSW / 3XSOW — cable cross-section
3XSW / 3XSOW3XSW / 3XSOW Oil-Resistant Elastomer Portable Cord
300/500 V
Motorised reel, trailing
IECRubber
300/500 V, IEC, Rubber sheathMotorised reel, trailing
(N)SSHCGEÖU — end cross section
(N)SSHCGEÖUNSSHCGEÖU 0.6/1 kV Coal Cutter Trailing Cable
0.6/1 kV
Motorised reel (limited), trailing, bretby handler, drilling rig
ICEA / MSHARubber
0.6/1 kV, ICEA / MSHA, Rubber sheathMotorised reel (limited), trailing, bretby handler, drilling rig
NSSHKCGEÖU — end cross section
NSSHKCGEÖUArmoured Coal Cutter Cable NSSHKCGEOEU 0.6/1 kV
0.6/1 kV
Motorised reel (limited), trailing, bretby handler, mine roadway
ICEA / MSHARubber
0.6/1 kV, ICEA / MSHA, Rubber sheathMotorised reel (limited), trailing, bretby handler, mine roadway

Choosing icea standard cables

Four things decide most selections. Our engineers check the rest against your application.

01 · Mechanical duty & installation profile

  • Match minimum bending radius, travel speed, and tensile load to the active duty profile (Motorised monospiral reel, Cylindrical / multi-layer drum, Festoon & line chain, Trailing & towing).
  • For continuous reeling, festoon, or drag-chain motion, specify fine-stranded Class 5/6 copper conductors with central strain-relief or anti-torsion braid.

02 · Rated voltage & cable family scope

  • This collection spans Trailing cables, VFD cables, Hook-up wire & equipment cables, Control cables, grouped below so power feeders, control circuits, and data/optical links can be specified side by side.
  • Account for voltage drop, ambient temperature derating, and symmetrical EMC screening on long runs or VFD motor drives.

03 · Standards compliance & outer sheath compound

  • Verify the governing regional or industry standard required by the project specification (IEC, VDE/DIN, UL, BS, ICEA/MSHA, etc.).
  • Use the outer-sheath filter to lock in PUR, heavy-duty EPR/PCP rubber, or low-smoke zero-halogen (LSZH) compounds for oil, abrasion, or fire safety.
Filter the range by standard

Questions buyers ask

Not covered here? Send your drawing and an engineer replies within 2 business hours.

Ask on WhatsApp
What rated voltages are available in the ICEA Standard Cables category?

Rated voltages run from 30 V to 35 kV across all 28 products. The most common rating is 600 V, listed for 10 products.

Which standards do the products in the ICEA Standard Cables category reference?

The products reference ICEA Standard (all 28 products), UL Standard (14 products), IEC Standard (7 products), and VDE / DIN Standard (3 products).

Are PDF datasheets available for the products in the ICEA Standard Cables category?

Yes. All 28 products have a PDF datasheet, linked from each product card and product page.

Engineering reference

Background on how icea standard cables are built, rated and specified.

Read the full reference

The ICEA Standard Cables collection brings together 28 industrial cable models across Trailing cables, VFD cables, Hook-up wire & equipment cables, Control cables, Power & connection cables, Rubber cables. US mining power and trailing cables to ICEA/NEMA, including ground-check types.

Use the multi-facet filter bar and duty matrix view to compare rated voltage, governing standard, outer sheath compound, and mechanical duty ratings side by side, or add candidate models to a combined engineering enquiry.

Compare cables

Voltage
Standard
Sheath
Features
Typical use

Highlighted rows differ between the selected cables.

Filters

Duty

Voltage

Standard

Sheath

Features