Contact
shipboard & offshore power cableIEC 60092-3541.8/3 kV – 12/20 kV (-40 to +90 °C)SHF1 / SHF2 Propulsion Outer Jacket

MPRXCX & MEPRXCX 1.8/3–12/20 kV IEC 60092-354 Flexible Shipboard MV Propulsion CableIEC 60092-354 — 1.8/3 kV – 12/20 kV — -40 to +90 °C Marine & Offshore Cable

MPRXCX & MEPRXCX 1.8/3–12/20 kV IEC 60092-354 Flexible Shipboard MV Propulsion Cable (IEC 60092-354) engineered for 1.8/3 kV – 12/20 kV service across -40 to +90 °C (min. bend radius 10 × OD).

Flame-retardant
EMC screen
Oil-resistant
Approved
Order designation
MPRXCX 3×50 mm² MV
Outer Ø ≈
42.5 mm
Net weight ≈
2,980 kg/km
Tensile rating ≈
22.5 kN
Core / stranding
IEC 60228 Class 2/5 Cu/SnCu
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
1.8/3 kV – 12/20
Tested per IEC 60092-354
Operating temp.
−40…+90 °C
Continuous shipboard & offshore service
Min. bend radius
10 × OD
Marine tray, bulkhead & deck routing
Core / conductor
Class 5 Flexible
Flexible Marine finely stranded annealed
Outer protection
SHF1 / SHF2 Prop
Halogen-free flame-retardant jacket cert
Standard
IEC 60092-354
IEC 60092-354 / IEC 60228 Class 5 / IEC

Typical values for this cable type, based on IEC 60092-354 / IEC 60228 Class 5 / IEC 60092-360 SHF1 & SHF2 — confirmed in the datasheet and quotation for your order.

Application fit

Is MPRXCX & MEPRXCX 1.8/3-12/20 KV right for your machine?

MPRXCX & MEPRXCX 1.8/3–12/20 kV IEC 60092-354 Flexible Shipboard MV Propulsion Cable (IEC 60092-354) engineered for 1.8/3 kV – 12/20 kV service across -40 to +90 °C (min. bend radius 10 × OD).

Offshore platform & shipboard deck trays

Suitable

Halogen-free SHF1/SHF2 or mud-resistant thermoset jacket withstands marine salt mist, oil and deck weathering.

Fixed installation

Suitable

Approved for bulkheads, cable trays, ladders and hull penetrations on commercial vessels and offshore units.

Drilling jumbo & rotary mast feed

Suitable

Metallic braid armour and cross-linked EPR/XLPE/XLPO insulation handle heavy mechanical and thermal duty.

Motor stator, traction & converter leads

Suitable

Stranded copper or tinned copper conductors terminate cleanly into marine switchboards, thrusters and transformers.

Energy chain / drag chain

Not suitable

Armoured shipboard and offshore feeder cable is not designed for high-cycle automation drag chains.

Use Drag-Chain Servo Cable
Typical machinesMarine & Offshore CableCommercial Vessels & Cruise ShipsOffshore Oil & Gas Platforms (FPSO)Jack-Up & Semi-Submersible Drilling RigsNaval Surface Vessels & Submarines

Construction

Layer by layer

Shown: MPRXCX & MEPRXCX 1.8/3-12/20 KV (IEC 60092-354 / IEC 60228 Class 5 / IEC 60092-360 SHF1 & SHF2) featuring class 5 flexible copper (3×120 mm²), triple-extruded xlpe / hepr insulation and shf1 / shf2 propulsion outer jacket (5-layer construction).

12345
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Class 5 Flexible Copper (3×120 mm²)Flexible Marine finely stranded annealed copper for tight bends
2Triple-Extruded XLPE / HEPR InsulationConductor screen + MV XLPE (MPRXCX) / HEPR (MEPRXCX) + insulation screen
3Individual Copper Tape Metallic ScreenOverlapped copper tape screen on each phase core
4Copper Wire Braid Armour (CX)High-coverage bare or tinned copper wire braid over halogen-free bedding
5SHF1 / SHF2 Propulsion Outer JacketHalogen-free flame-retardant jacket certified by DNV, BV, LR, ABS

MPRXCX & MEPRXCX 1.8/3-12/20 KV — Standard Shipboard & Offshore Execution

Built to IEC 60092-354 / IEC 60228 Class 5 / IEC 60092-360 SHF1 & SHF2 with class 5 flexible copper (3×120 mm²) and shf1 / shf2 propulsion outer jacket

MPRXCX & MEPRXCX 1.8/3-12/20 KV — Custom Drum Length & Gland Kit

Available in custom continuous shipboard/offshore drum lengths or with marine EMC cable glands

MPRXCX & MEPRXCX 1.8/3-12/20 KV — Class & Routine Test Certified

Supplied with EN 10204 3.1 routine dielectric, conductor resistance & flame/fire test report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on IEC 60092-354 / IEC 60228 Class 5 / IEC 60092-360 SHF1 & SHF2. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
1.8/3 kV – 12/20 kV (IEC 60092-354 / IEC 60228 Class 5 / IEC 60092-360 SHF1 & SHF2)
Core / conductor construction
Class 5 Flexible Copper (3×120 mm²) — Flexible Marine finely stranded annealed copper for tight bends
Primary dielectric / buffering
Triple-Extruded XLPE / HEPR Insulation — Conductor screen + MV XLPE (MPRXCX) / HEPR (MEPRXCX) + insulation screen

Thermal

Continuous operating temperature
−40…+90 °C (shipboard & offshore duty)
Short-circuit / peak thermal rating
Verified thermal stability per IEC 60092-354 / IEC 60228 Class 5 / IEC 60092-360 SHF1 & SHF2
Storage & transport temperature
−40…+80 °C on export wooden/steel drum

Mechanical

Outer protection / armouring
SHF1 / SHF2 Propulsion Outer Jacket — Halogen-free flame-retardant jacket certified by DNV, BV, LR, ABS
Minimum bending radius
10 × OD
Armour, screen & mechanical duty
Copper Wire Braid Armour (CX) — High-coverage bare or tinned copper wire braid over halogen-free bedding

Resistance

Flame, fire & smoke performance
Qualified for marine flame-retardance and low-smoke zero-halogen / fire safety per IEC 60092-354 / IEC 60228 Class 5 / IEC 60092-360 SHF1 & SHF2
Oil, drilling mud & seawater resistance
Resistant to marine fuel/lube oils, salt mist and offshore fluids per IEC 60092-354 / IEC 60228 Class 5 / IEC 60092-360 SHF1 & SHF2
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
IEC 60092-354 / IEC 60228 Class 5 / IEC 60092-360 SHF1 & SHF2
Environmental & test standards
IEC 60228 / IEC 60332-3-22 / IEC 60754 / IEC 61034 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
MPRXCX & MEPRXCX 1.8/3-12/20 KV
Sheath colour & metre marking
Continuous metre-marked black outer finish (SHF1 / SHF2 Prop)
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard MPRXCX & MEPRXCX 1.8/3-12/20 KV shipboard & offshore configurations

Manufactured to IEC 60092-354 / IEC 60228 Class 5 / IEC 60092-360 SHF1 & SHF2 for shipboard, offshore platform, drilling rig and marine applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Tensile rating
kN ≈
Min. bend R
mm
Enquiry
MPRXCX & MEPRXCX 1.8/3-12/20 KV Construction Schedule (−40…+90 °C)
MPRXCX 3×50 mm² MV3 × 50 mm²IEC 60228 Class 2/5 Cu/SnCu42.52,98022.5510
MPRXCX 3×95 mm² MV3 × 95 mm²IEC 60228 Class 2/5 Cu/SnCu51.84,69042.8620
MPRXCX 3×150 mm² MV3 × 150 mm²IEC 60228 Class 2/5 Cu/SnCu61.26,84067.5735
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour grades and factory drum lengths available per IEC 60092-354 / IEC 60228 Class 5 / IEC 60092-360 SHF1 & SHF2.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, continuity & dimensional verification (IEC 60092-354 / IEC 60228 Class 5 / IEC 60092-360 SHF1 & SHF2)DC resistance at 20 °C / optical attenuation and outer diameter within IEC 60092-354 / IEC 60228 Class 5 / IEC 60092-360 SHF1 & SHF2 tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (IEC 60092-354 / IEC 60228 Class 5 / IEC 60092-360 SHF1 & SHF2)Zero dielectric breakdown and verified insulation resistance for 1.8/3 kV – 12/20 kV ratingEvery manufactured drum length
Sample tests
Flame, fire integrity, oil/mud & mechanical qualification (IEC 60092-354 / IEC 60228 Class 5 / IEC 60092-360 SHF1 & SHF2)Verified flame/fire performance, fluid resistance and thermal stability across −40…+90 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

IEC 60092-354 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX MPRXCX & MEPRXCX 1.8/3-12/20 KV IEC 60092-354 1.8/3 kV – 12/20 kV CE
Delivery form
Heavy-duty export fumigated wooden drums or steel marine reels
Standard lengths
500 m, 1,000 m or custom continuous shipboard/offshore lengths
MOQ
100 m (standard configurations) · 500 m (custom builds)
Lead time
2–5 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-25
Updated
2026-10-25

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define MPRXCX & MEPRXCX 1.8/3-12/20 KV (MPRXCX & MEPRXCX 1.8/3–12/20 kV IEC 60092-354 Flexible Shipboard MV Propulsion Cable)?
MPRXCX & MEPRXCX 1.8/3-12/20 KV (MPRXCX & MEPRXCX 1.8/3–12/20 kV IEC 60092-354 Flexible Shipboard MV Propulsion Cable) is manufactured in accordance with IEC 60092-354 / IEC 60228 Class 5 / IEC 60092-360 SHF1 & SHF2 for 1.8/3 kV – 12/20 kV service over -40 to +90 °C. Its 5-layer construction comprises class 5 flexible copper (3×120 mm²), triple-extruded xlpe / hepr insulation and shf1 / shf2 propulsion outer jacket.
What is the minimum bending radius and operating temperature range for MPRXCX & MEPRXCX 1.8/3-12/20 KV?
The minimum bending radius for MPRXCX & MEPRXCX 1.8/3-12/20 KV is 10 × OD across its continuous operating temperature range of -40 to +90 °C, ensuring mechanical and dielectric reliability in shipboard and offshore service.
How are the concentric layers of MPRXCX & MEPRXCX 1.8/3-12/20 KV arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Class 5 Flexible Copper (3×120 mm²) — Flexible Marine finely stranded annealed copper for tight bends; (02) Triple-Extruded XLPE / HEPR Insulation — Conductor screen + MV XLPE (MPRXCX) / HEPR (MEPRXCX) + insulation screen; (03) Individual Copper Tape Metallic Screen — Overlapped copper tape screen on each phase core; (04) Copper Wire Braid Armour (CX) — High-coverage bare or tinned copper wire braid over halogen-free bedding; (05) SHF1 / SHF2 Propulsion Outer Jacket — Halogen-free flame-retardant jacket certified by DNV, BV, LR, ABS.
What factory test certificates are supplied with MPRXCX & MEPRXCX 1.8/3-12/20 KV?
Every production drum of MPRXCX & MEPRXCX 1.8/3-12/20 KV undergoes routine conductor resistance/continuity, high-voltage dielectric and dimensional testing per IEC 60092-354 / IEC 60228 Class 5 / IEC 60092-360 SHF1 & SHF2, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for MPRXCX & MEPRXCX 1.8/3-12/20 KV

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

MPRXCX & MEPRXCX 1.8/3–12/20 kV IEC 60092-354 Flexible Shipboard MV Propulsion Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote