Fixed installation
Pulled in continuous 100–500 m pre-reacted lengths through vertical shafts and service tunnels between surface converters and.
Product
High-current DC superconducting transfer line cable (MgB2 Superconducting Link Cable) built to IEC 61788-27 and CERN HiLumi LHC specifications using ex-situ Powder-in-Tube (PIT) multifilamentary Magnesium Diboride (MgB₂, Tc = 39 K) round wires in a.
Typical values for this cable type, based on IEC 61788-27 / CERN HiLumi LHC WP6a / Cryogenic DC Link Std — confirmed in the datasheet and quotation for your order.
Application fit
Enables remote placement of room-temperature power converters 100 to 500 metres away from radiation or underground magnet galleries by transporting up to 120 kA of DC current through a single flexible Ø 160–220 mm gaseous-helium cryostat operating at 18–25 K.
Pulled in continuous 100–500 m pre-reacted lengths through vertical shafts and service tunnels between surface converters and.
Cooled by low-density forced-flow gaseous helium (GHe at 18–25 K, 2–4 bar) or liquid hydrogen (LH₂ at 20 K).
Replaces puluhan tonnes of rigid water-cooled copper busbars in accelerator tunnels, fusion tokamak buildings and.
Cryogenic superconducting transfer line; not a movable machinery drag-chain cable.
YHKGXSFoyn Shaft Wire-Armoured CableConstruction
Shown: MgB2-Link-120kA-HiLumi multi-circuit DC transfer bundle containing 18 kA, 10 kA, 3 kA and 0.6 kA concentric/twisted MgB₂ sub-cables (Ø 1.0 mm 37-filament MgB₂ in Monel/Ni matrix with tin-coated OFHC copper core and copper stabilization braid), polyimide insulation and flexible double-walled vacuum cryostat.
| # | Layer | Material & reference |
|---|---|---|
| 1 | Helical layer of ex-situ PIT MgB₂ round strands | 6 to 24 round multifilamentary MgB₂ wires (Ø 0.85–1.0 mm, 37 MgB₂ filaments in Ni/NbDelivers ≥ 500–600 A per 1 mm wire at 20 K, 0.5–1.0 T with isotropic round-wire geometry |
| 2 | Central OFHC copper stabilizer core | Stranded tin-plated Oxygen-Free High-Conductivity (OFHC, RRR > 100) copper ropeProvides thermal heat capacity and parallel current bypass during a magnet quench |
| 3 | Outer OFHC copper wire braid & polyimide dielectric | Braided tinned copper thermal/electrical shunt + overlapped polyimide film & PEEK/glassElectrically isolates individual circuits inside a compact multi-pole bundle |
| 4 | Flexible corrugated AISI 316L vacuum-insulated cryostat | Concentric inner GHe flow pipe + multi-layer superinsulation (MLI) under 10⁻⁶ mbar vacuumLimits static heat load to < 1.5 W/m over 100–500 m transfer runs |
Pre-reacted round MgB₂ + OFHC copper unit cables supplied on Ø 2.5 m spools for custom cryostats
Complete multi-pole bundle pulling up to 19 independent DC circuits inside one flexible GHe cryostat
Technical data
Sizes
Pre-reacted MgB₂ unit sub-cables (3–18 kA) and complete multi-circuit cryogenic transfer links (60–120 kA).
| Order designation | MgB₂ strand layout | Form factor | Bundle Ø mm | Rated DC I kA | T_op K | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| Pre-Reacted 20 K MgB₂ Unit Sub-Cables (3 kA to 18 kA DC) | |||||||
| MgB2-Sub-3kA-20K | 6ר1.0 mm MgB₂ around Cu core | Ø 4.1 mm Sub-cable | 4.1 | 3.2 | 20.0 | 120 | |
| MgB2-Coax-10kA-20K | 2×12 MgB₂ concentric (±10 kA) | Ø 16.5 mm Coaxial | 16.5 | 10.0 | 20.0 | 350 | |
| MgB2-Monopole-18kA-20K | 18ר1.0 mm MgB₂ + Cu braid | Ø 19.2 mm Cable | 19.2 | 18.0 | 20.0 | 400 | |
| Complete Multi-Circuit & Bi-Pole 20 K MgB₂ Superconducting Transfer Links | |||||||
| MgB2-Link-60kA-Cryo | 2×18kA + 4×3kA + 12×0.6kA bundle | Ø 65 mm Cable / Ø 160 Cryo | 65.0 | 60.0 | 20.0 | 1,200 | |
| MgB2-Link-120kA-HiLumi | 19-circuit multi-pole DC bundle | Ø 90 mm Cable / Ø 220 Cryo | 90.0 | 120.0 | 20.0 | 1,800 | |
| MgB2-HVDC-20kV-50kA | 2×25 kA ±20 kV DC bi-pole | Ø 78 mm Cable / Ø 190 Cryo | 78.0 | 50.0 | 20.0 | 1,500 | |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| IEC 61788-27 strand I_c @ 20 K & 2-bar gaseous helium HV Paschen test | Meets 20 K critical current with zero partial discharge in 1 bar / 2 bar GHe | Every strand & cable lot |
| Sample tests | ||
| Full-scale bending & thermal-cycling endurance test (300 K ↔ 20 K) | ≥ 97 % I_c retention after spooling and shaft routing simulation | Qualification length |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.