Fixed installation
Approved for cable tray, duct, direct burial or clipped fixed installations per applicable wiring regulations.
Product
Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.
Typical values for this cable type, based on Reference specification per BS EN 60228 Class 6 (Twinflex 450/750V Red/Black TPE & Transparent) — confirmed in the datasheet and quotation for your order.
Application fit
Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.
Approved for cable tray, duct, direct burial or clipped fixed installations per applicable wiring regulations.
Flexible stranded conductors withstand equipment vibration, mobile hook-ups and routine flexing.
Fixed or moderate-flex construction; for continuous high-acceleration drag chains, select a dedicated Class 6 chain cable.
Outer sheath compound resists industrial oils, moisture ingress, abrasion and outdoor weathering.
Not intended for high-tension crane spreader reeling drums; select a dedicated 2PNCT or 3PNCT reeling cable.
Use TRA 0.6/1 kV PUR Reeling CableScreened 450/750 V TPE/PVC construction suppresses electromagnetic interference on shared industrial power and PLC signal trays.
Construction
Cross-section colours are aligned to the supplied product cutaway; layer dimensions follow the reference specification.

| # | Layer | Material & reference |
|---|---|---|
| 1 | Conductor | 2×16 mm² Class 6 Extra-Flexible Bare Cu |
| 2 | Insulation & Core Identification | Red (+) and Black (-) flexible TPE core insulation (16 mm² Class 6 Cu) |
| 3 | Screen / Bedding / Armour Layer | Parallel twin figure-8 flat core alignment bridge between Red (+) and Black (-) TPE cores |
| 4 | Outer Protective Sheath | Transparent flat webbed flexible PVC outer sheath (10.0 × 21.5 mm) |
Class 6 Extra-Flexible Bare Copper · Outer diameter 16.5 mm
Class 6 Extra-Flexible Bare Copper · Outer diameter 19.5 mm
Class 6 Extra-Flexible Bare Copper · Outer diameter 22.8 mm
Technical data
Sizes
Representative configurations from the series specification; select a row to prefill the quotation tool.
| Configuration | Conductor & shield | Insulation / wall | Outer sheath | Outer diameter mm | Min. bend radius mm | Max. conductor resistance @ 20 °C Ω/km | Copper weight kg/km | Cable weight kg/km | Key electrical / optical rating | Part designation | Enquiry |
|---|---|---|---|---|---|---|---|---|---|---|---|
| Twinflex 450/750V Red/Black TPE & Transparent | |||||||||||
| 2×16 mm² | Class 6 Extra-Flexible Bare Copper | Red and Black flexible TPE core insulation | Industrial PVC | 16.5 | 99 | 1.13 | 332.8 | 640 | 80 A | Twinflex 450/750V Red/Black TPE & Transparent (2×16 mm²) | |
| 2×25 mm² | Class 6 Extra-Flexible Bare Copper | Red and Black flexible TPE core insulation | Industrial PVC | 19.5 | 117 | 0.72 | 463.3 | 891 | 106 A | Twinflex 450/750V Red/Black TPE & Transparent (2×25 mm²) | |
| 2×35 mm² | Class 6 Extra-Flexible Bare Copper | Red and Black flexible TPE core insulation | Industrial PVC | 22.8 | 137 | 0.52 | 633.4 | 1,218 | 131 A | Twinflex 450/750V Red/Black TPE & Transparent (2×35 mm²) | |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance & continuity | Within maximum Ω/km limit at 20 °C per IEC 60228 / BS EN 60228 | Every manufactured drum length |
| Dielectric withstand / spark test | No breakdown across insulation, screen or armour | Every manufactured drum length |
| Sample tests | ||
| Vertical flame propagation & jacket qualification | Self-extinguishing and compliant with reference standard limits | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.