Contact

S1108 (EME-SP-14-025) 750V DC LUL Traction Feeder CableS1108 (EME-SP-14-025) 750V DC LUL Traction Feeder Cable manufactured to LUL S1108 / EME-SP-14-025 / LUL 1-085, rated 750 V DC and -25°C to +85°C with a 12 × OD minimum bending radius for infrastructure & construction installations.

Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.

Flame-retardant
Oil-resistant
Approved
Order designation
S1108 (EME-SP-14-025) 750V DC LUL Traction (1×500 mm²)
Outer diameter
56.0 mm
Cable weight
7,370 kg/km
Min. bend radius
672 mm
Conductor & shield
Stranded Tinned Copper
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
750 V DC
LUL S1108 / EME-SP-14-025 / LUL 1-085
Temperature
-25°C to +85°C
Fixed / flex duty
Min. bend radius
12 × OD
56.0–77.3 mm
Screening
Unshielded
Fixed / flex duty
Outer sheath
LSZH Jacket
Halogen-free fire-safety corridors
Core / size range
3 sizes
3 standard configurations

Typical values for this cable type, based on Reference specification per LUL S1108 / EME-SP-14-025 / LUL 1-085 (S1108 (EME-SP-14-025) 750V DC LUL Traction) — confirmed in the datasheet and quotation for your order.

Application fit

Is S1108 (EME-SP-14-025) 750V DC LUL Traction right for your machine?

Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.

Fixed installation

Suitable

Approved for cable tray, duct, direct burial or clipped fixed installations per applicable wiring regulations.

Motor stator, traction & converter leads

Suitable

Flexible stranded conductors withstand equipment vibration, mobile hook-ups and routine flexing.

Energy chain / drag chain

With conditions

Fixed or moderate-flex construction; for continuous high-acceleration drag chains, select a dedicated Class 6 chain cable.

TBM gantry & advancing tunnel reel

Suitable

Low-smoke zero-halogen outer sheath minimizes toxic acid gas emission and smoke obscuration in fire events.

Vertical / spreader reel

Not suitable

Not intended for high-tension crane spreader reeling drums; select a dedicated 2PNCT or 3PNCT reeling cable.

Use TRA 0.6/1 kV PUR Reeling Cable

Railcar bogie & underframe harness

Suitable

Low-toxicity fire-safe 750 V DC EPR/LSZH construction fits railcar underframes, bogie jumpers, and enclosed passenger coach conduits.

Typical machinesBuilding & Fire SafetyPower distribution & utility networksRailways, tunnels & public infrastructureProcess instrumentation & oil/gas skidsIndustrial automation & control cabinetsRenewable energy, marine & heavy industry

Construction

Layer by layer

Cross-section colours are aligned to the supplied product cutaway; layer dimensions follow the reference specification.

S1108 (EME-SP-14-025) 750V DC LUL Traction – Layered cable cutaway
Layer cutaway
#LayerMaterial & reference
1Conductor1×500 mm² Class 2 Stranded Tinned Cu
2Insulation & Core IdentificationLUL S1108 heavy-wall EPR (Ethylene Propylene Rubber) traction insulation (500 mm² TC)
3Screen / Bedding / Armour LayerPolyester separator tape
4Outer Protective SheathBlack LUL 1-085 LSZH outer sheath with yellow longitudinal stripe (OD 56.0 mm)

1×500 mm²

Stranded Tinned Copper · Outer diameter 56.0 mm

1×400 mm²

Stranded Tinned Copper · Outer diameter 66.1 mm

1×630 mm²

Stranded Tinned Copper · Outer diameter 77.3 mm

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on Reference specification per LUL S1108 / EME-SP-14-025 / LUL 1-085 (S1108 (EME-SP-14-025) 750V DC LUL Traction). Values for your order are confirmed in the datasheet and quotation.

Electrical

Nominal / reference voltage
750 V DC
Conductor & core insulation
1×500 mm² Class 2 Stranded Tinned Cu · LUL S1108 heavy-wall EPR (Ethylene Propylene Rubber) traction insulation (500 mm² TC)
Routine dielectric / continuity test
100% factory drum spark & continuity verified

Thermal

Operating temperature range
-25°C to +85°C
Short-circuit / peak thermal limit
+160 °C to +250 °C (5 s conductor thermal limit)
Flame & fire performance
LUL S1108 / EME-SP-14-025 / LUL 1-085

Mechanical

Minimum bending radius
12 × OD
Screening / armour architecture
Polyester separator tape
Outer sheath material & colour
Black LUL 1-085 LSZH outer sheath with yellow longitudinal stripe (OD 56.0 mm)

Reference standards

Reference standard
LUL S1108 / EME-SP-14-025 / LUL 1-085
Hazardous Substance Compliance
CE, UKCA, RoHS 2 (2011/65/EU) & REACH SVHC compliant
Quality & Batch Traceability
EN 10204 3.1 Factory Inspection Certificate

Sizes

Sizes & engineering data

Representative configurations from the series specification; select a row to prefill the quotation tool.

All sizes
ConfigurationConductor & shieldInsulation / wallOuter sheathOuter diameter
mm
Min. bend radius
mm
Max. conductor resistance @ 20 °C
Ω/km
Copper weight
kg/km
Cable weight
kg/km
Key electrical / optical ratingPart designationEnquiry
S1108 (EME-SP-14-025) 750V DC LUL Traction
1×500 mm²Stranded Tinned CopperLUL S1108 heavy-wall EPR traction insulationLSZH Jacket56.06720.043,832.47,370670 AS1108 (EME-SP-14-025) 750V DC LUL Traction (1×500 mm²)
1×400 mm²Stranded Tinned CopperLUL S1108 heavy-wall EPR traction insulationLSZH Jacket66.17930.055,335.710,261580 AS1108 (EME-SP-14-025) 750V DC LUL Traction (1×400 mm²)
1×630 mm²Stranded Tinned CopperLUL S1108 heavy-wall EPR traction insulationLSZH Jacket77.39280.037,298.214,035760 AS1108 (EME-SP-14-025) 750V DC LUL Traction (1×630 mm²)
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Dimensions and weights are nominal manufacturing targets subject to standard production tolerances.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance & continuityWithin maximum Ω/km limit at 20 °C per IEC 60228 / BS EN 60228Every manufactured drum length
Dielectric withstand / spark testNo breakdown across insulation, screen or armourEvery manufactured drum length
Sample tests
Vertical flame propagation & jacket qualificationSelf-extinguishing and compliant with reference standard limitsType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

LUL S1108 / EME-SP-14-025 / LUL 1-085 CompliantEN 10204 3.1 Factory Test CertificateCE, UKCA, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

S1108 (EME-SP-14-025) 750V DC LUL TRACTION FEEDER CABLE / TEBAOFLEX.COM — sequential metre marking
Delivery form
Heavy-duty export fumigated wooden drums or steel reels with moisture-sealed ends
Standard lengths
250 m, 500 m, 1000 m continuous drum lengths or custom cut-to-length runs
MOQ
100 m (standard configurations) · 300 m (custom builds)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-11-04
Updated
2026-11-04

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What applications is S1108 (EME-SP-14-025) 750V DC LUL Traction designed for?
S1108 (EME-SP-14-025) 750V DC LUL Traction is engineered for infrastructure & construction installations under LUL S1108 / EME-SP-14-025 / LUL 1-085, operating over -25°C to +85°C with a minimum bending radius of 12 × OD.
How is S1108 (EME-SP-14-025) 750V DC LUL Traction constructed across its layers?
Its 4-layer architecture combines 1×500 mm² Class 2 Stranded Tinned Cu with LUL S1108 heavy-wall EPR (Ethylene Propylene Rubber) traction insulation (500 mm² TC), Polyester separator tape and Black LUL 1-085 LSZH outer sheath with yellow longitudinal stripe (OD 56.0 mm).
What standards and routine factory tests apply to S1108 (EME-SP-14-025) 750V DC LUL Traction?
Every manufactured drum is tested to LUL S1108 / EME-SP-14-025 / LUL 1-085 for conductor continuity, dielectric voltage withstand and sheath integrity, supplied with an EN 10204 3.1 inspection certificate.
What sizes and drum lengths are available for S1108 (EME-SP-14-025) 750V DC LUL Traction?
Representative sizes include 1×500 mm², 1×400 mm² and 1×630 mm², supplied on 250 m, 500 m or 1,000 m export drums or custom cut lengths.
Which technical documents are available?
Reference files are provided for project screening. Final parameters and the applicable document package are confirmed during quotation.

Request a quote

Get an engineering quote for S1108 (EME-SP-14-025) 750V DC LUL Traction

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

S1108 (EME-SP-14-025) 750V DC LUL Traction Feeder Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote