Immersion & wet locations
Submarine armoured PE/PP builds and AD8 submersible jackets withstand seabed burial, wave catenaries and continuous seawater immersion.
Product
MV Submarine Power & Electro-Optical Composite Cable featuring single-mode / multi-mode optical unit and subsea / marine outer protective sheath (IEC 60502-2 / CIGRE TB 490, 6/10 kV – 18/30 kV, -20 to +90 °C, min. bend radius 15 × OD).
Typical values for this cable type, based on IEC 60502-2 & CIGRE TB 490 MV Submarine Electro-Optical Composite Standard — confirmed in the datasheet and quotation for your order.
Application fit
MV Submarine Power & Electro-Optical Composite Cable featuring single-mode / multi-mode optical unit and subsea / marine outer protective sheath (IEC 60502-2 / CIGRE TB 490, 6/10 kV – 18/30 kV, -20 to +90 °C, min. bend radius 15 × OD).
Submarine armoured PE/PP builds and AD8 submersible jackets withstand seabed burial, wave catenaries and continuous seawater immersion.
IEC 60502-1/-2 and IEC 60092-353 constructions install across shore landings, inter-cage subsea grids and shipboard cable trays.
Resistant to seawater, diesel oil, UV weathering and mechanical impact on floating aquaculture collars and port quaysides.
Dynamic aquaculture catenary and flexible shore-power builds absorb tidal rise, vessel heave and pontoon motion.
Submarine armoured feeders and shipboard power cables are not designed for high-cycle automated drag chains.
Use FD 855 P Drag-Chain CableConstruction
Shown: MV Submarine EO Composite Cable (IEC 60502-2 & CIGRE TB 490 MV Submarine Electro-Optical Composite Standard) featuring single-mode / multi-mode optical unit, power & control copper conductors and subsea / marine outer protective sheath (4-layer construction).

| # | Layer | Material & reference |
|---|---|---|
| 1 | Single-Mode / Multi-Mode Optical Unit | Hermetic stainless-steel tube / tight-buffered optical unit |
| 2 | Power & Control Copper Conductors | Stranded copper conductors with Cross-linked polyethylene (XLPE) insulation |
| 3 | Galvanized Steel Wire Armour | High-strength galvanized steel wire armour layer |
| 4 | Subsea / Marine Outer Protective Sheath | Black heavy-duty submersible elastomeric outer sheath |
Built to IEC 60502-2 & CIGRE TB 490 MV Submarine Electro-Optical Composite Standard with single-mode / multi-mode optical unit and subsea / marine outer protective sheath
Available on continuous export winch drums or factory-terminated with subsea wet-mate / mechanical sockets
Supplied with EN 10204 3.1 routine dielectric, conductor/optical continuity & hydrostatic qualification report
Technical data
Sizes
Manufactured to IEC 60502-2 & CIGRE TB 490 MV Submarine Electro-Optical Composite Standard for subsea robotics, ROV umbilicals, marine aquaculture and offshore sensor applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Max. pulling kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| MV Submarine EO Composite Cable Construction Schedule (−20…+90 °C) | |||||||
| MV Submarine EO Composite Cable 3×6 + 4×SM + 2TP | 3×6 mm² Power + 4×SM Fiber + 2×2×0.75 | SnCu + Gel Tube + Contra-Helical GSWA | 20.8 | 1,280 | 115.0 | 250 | |
| MV Submarine EO Composite Cable 3×10 + 6×SM + 4T | 3×10 mm² Power + 6×SM Fiber + 4×2×0.75 | SnCu + SS Tube + Double Steel Armour | 25.4 | 1,890 | 185.0 | 305 | |
| MV Submarine EO Composite Cable 3×16 + 8×SM/MM | 3×16 mm² Power + 8×SM/MM + 3×2×1.0 | SnCu + SS Tube + Heavy GSWA Pack | 30.2 | 2,680 | 260.0 | 365 | |
| Configuration | Max. DC R₂₀ Ω/km | Rating / Impedance / Load | Operating temp. |
|---|---|---|---|
| 3×6 mm² Power + 4×SM Fiber + 2×2×0.75 | 3.30 | 6/10 kV – 18/30 kV · 115 kN MBS | −20…+90 °C |
| 3×10 mm² Power + 6×SM Fiber + 4×2×0.75 | 1.91 | 6/10 kV – 18/30 kV · 185 kN MBS | −20…+90 °C |
| 3×16 mm² Power + 8×SM/MM + 3×2×1.0 | 1.21 | 6/10 kV – 18/30 kV · 260 kN MBS | −20…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor DC resistance / OTDR optical & dimensional check (IEC 60502-2 & CIGRE TB 490 MV Submarine Electro-Optical Composite Standard) | DC resistance at 20 °C, optical attenuation and wall thickness within IEC 60502-2 & CIGRE TB 490 MV Submarine Electro-Optical Composite Standard limits | Every manufactured drum length |
| AC high-voltage dielectric & insulation resistance test (IEC 60502-2 & CIGRE TB 490 MV Submarine Electro-Optical Composite Standard) | Zero dielectric breakdown and verified wet insulation resistance for 6/10 kV – 18/30 kV rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, tensile load & seawater immersion qualification (IEC 60502-2 & CIGRE TB 490 MV Submarine Electro-Optical Composite Standard) | Verified hydrostatic pressure integrity, breaking load and flex endurance across −20…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.