Fixed installation
Durable 1000 V EPDM/PCP geometry installs cleanly along transformer links, busbar transitions, trays, and industrial bays.
Product
ACC 300–800 Air-Cooled encloses ultra-flexible rope-lay bare copper bundles in a thick heat- & abrasion-resistant black EPDM/PCP rubber sheath for air-cooled transformer, rectifier, and furnace secondary jumpers.
Typical values for this cable type, based on IEC 60228 Class 6 · EN 50525-2-81 (ref.) · DIN VDE 0282 — confirmed in the datasheet and quotation for your order.
Application fit
ACC 300–800 Air-Cooled encloses ultra-flexible rope-lay bare copper bundles in a thick heat- & abrasion-resistant black EPDM/PCP rubber sheath for air-cooled transformer, rectifier, and furnace secondary jumpers.
Durable 1000 V EPDM/PCP geometry installs cleanly along transformer links, busbar transitions, trays, and industrial bays.
Extra-flexible 1000 V EPDM/PCP stranding and 8×D bend radius connect dynamic welding guns, drives, and furnace feeders.
Rugged 1000 V EPDM/PCP construction handles stationary heavy-plant cable trenches, rolling-mill feeders, and industrial power bays.
Extra-flexible heat- and spatter-resistant 1000 V EPDM/PCP build delivers low-drop current to welding tongs and shop floor leads.
1000 V EPDM/PCP construction is built for stationary or light-flex runs, not continuous high-cycle drag-chain flexing.
Use (N)12YRDC11Y-J/O PUR1000 V EPDM/PCP outer sheath is not AD8-rated for permanent water submersion; specify a submersible EPDM or water-blocked cable.
Use EMC-VFD Submersible EPDMConstruction
Representative construction of ACC 300-800 Air-Cooled Cable: IEC 60228 Class 6 extra-flexible bare annealed copper, Separator fleece + heavy-duty rubber elastomeric insulation/sheath, and Black heat-, oil- & abrasion-resistant EPDM/PCP rubber outer sheath.
| # | Layer | Material & reference |
|---|---|---|
| 1 | Conductor | IEC 60228 Class 6 extra-flexible bare annealed copperIEC 60228 Class 6 |
| 2 | Cooling core / primary dielectric | Separator fleece + heavy-duty rubber elastomeric insulation/sheathIEC 60228 Class 6 |
| 3 | Outer sheath / hose | Black heat-, oil- & abrasion-resistant EPDM/PCP rubber outer sheath300–800 mm² High Current |
Single-core high-duty construction protected by Black heat-, oil- & abrasion-resistant EPDM/PCP rubber outer sheath.
Technical data
Sizes
| Cross-section mm² | Outer Ø ≈ mm | Max. R20 Ω/km | Copper index kg/km | Weight ≈ kg/km | Min. bend R 8×D mm |
|---|---|---|---|---|---|
| 1×300 mm² | 31.0 | 0.064 | 2,880 | 4,426 | 248 |
| 1×400 mm² | 34.8 | 0.049 | 3,840 | 5,856 | 278 |
| 1×500 mm² | 38.1 | 0.038 | 4,800 | 7,280 | 305 |
| 1×630 mm² | 41.9 | 0.029 | 6,048 | 9,125 | 335 |
| 1×800 mm² | 46.4 | 0.024 | 7,680 | 11,537 | 371 |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| High-voltage dielectric withstand test | 3.5 kV AC without breakdown | Every manufactured length |
| Continuity & conductor DC resistance | Per IEC 60228 Class 6 at 20 °C | Every drum / assembly |
| Sample tests | ||
| Tensile, dimensional & pressure check | Rated -30 °C to +90 °C continuous | Per production lot |
| Environmental, thermal & mechanical qualification | 300–800 mm² High Current · Oil, Ozone & Heat Rubber | Type approval |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.