Trailing & towing
Smooth, low-friction round PVC jacket glides over carpets, furniture corners and commercial tile floors without snagging.
Product
Type SVT (Service Vacuum Thermoplastic) is a lightweight, compact 300 V round flexible appliance cord manufactured to UL 62 and CSA C22.2 No. 49. Built with fine-stranded ASTM B174 bare copper conductors in 18 AWG and 16 AWG (2 or 3 conductors, 0.38 mm / 15-mi
Typical values for this cable type, based on UL 62 / CSA C22.2 No. 49 / NEC Art. 400 — confirmed in the datasheet and quotation for your order.
Application fit
Specified for commercial and household upright/canister vacuum cleaners, hospital and dental equipment carts, computer/PDU power cords, audio/lighting pendants and compact spring-wind appliance reels.
Smooth, low-friction round PVC jacket glides over carpets, furniture corners and commercial tile floors without snagging.
Slim 6.0–6.8 mm diameter packs 40 % more cord length onto internal vacuum and appliance spring reels than SJT.
Approved by NEC Table 400.4 for indoor pendant and portable appliance supply cords.
Designed for dry/damp indoor light-duty use; for outdoor wet or oily shop service specify SJTOW or SJTOOW.
SJTOW outdoor portable cordConstruction
Fine bunch-stranded bare copper (41/34 AWG on 18 AWG or 65/34 AWG on 16 AWG) + 0.38 mm (15 mil) thermoplastic PVC core insulation + paper/textile separator + 0.76 mm (30 mil) smooth thermoplastic PVC outer jacket.
| # | Layer | Material & reference |
|---|---|---|
| 1 | Fine bunch-stranded copper (34/30 AWG wires) | Extra-limp 41×34 AWG (or 16×30 AWG) on 18 AWG and 65×34 AWG (or 26×30 AWG) on 16 AWG per UL 62ASTM B174 |
| 2 | Thin-wall thermoplastic PVC (15 mil) | 0.38 mm (0.015 in) colour-coded PVC insulation (Black, White, Green or Blue, Brown, Green/Yellow)UL 62 |
| 3 | Paper / fibrillated separator tissue | Allows the outer PVC jacket to strip cleanly for high-speed moulded plug terminationUL 62 |
| 4 | Smooth appliance-grade PVC jacket (30 mil) | 0.76 mm (0.030 in) non-marking, low-friction PVC outer jacket in Black, White, Grey or custom OEM Pantone coloursUL 62 |
Ultra-supple 34 AWG strand construction engineered specifically for commercial vacuum cleaners and spring cord rewinders.
105 °C VW-1 / FT2 rated SVT with North American (Black/White/Green) or International (Brown/Blue/Green-Yellow) core colours.
Technical data
Sizes
Nominal dimensions, copper weight, total mass and electrical parameters for SVT per UL 62 / CSA C22.2 No. 49 / NEC Art. 400.
| Designation | AWG × Conductors | Stranding / NEC Amps | Nom. OD mm | Copper kg/km | Total mass ≈ kg/km | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| SVT size schedule | |||||||
| SVT 18/2 (16/30) | 18 AWG × 2C | 16/30 · 10 A | 5.90 | 17.5 | 44.0 | 23.6 | |
| SVT 18/2 (41/34) | 18 AWG × 2C Limp | 41/34 · 10 A | 5.90 | 17.5 | 44.0 | 23.6 | |
| SVT 18/3 (16/30) | 18 AWG × 3C | 16/30 · 10 A | 6.30 | 26.2 | 56.0 | 25.2 | |
| SVT 18/3 (41/34) | 18 AWG × 3C Limp | 41/34 · 10 A | 6.30 | 26.2 | 56.0 | 25.2 | |
| SVT 17/3 | 17 AWG × 3C | 21/30 · 12 A | 6.55 | 33.0 | 65.0 | 26.2 | |
| SVT 16/2 (26/30) | 16 AWG × 2C | 26/30 · 13 A | 6.40 | 27.8 | 58.0 | 25.6 | |
| SVT 16/3 (26/30) | 16 AWG × 3C | 26/30 · 13 A | 6.80 | 41.7 | 74.0 | 27.2 | |
| SVT 16/3 (65/34) | 16 AWG × 3C Limp | 65/34 · 13 A | 6.80 | 41.7 | 74.0 | 27.2 | |
| AWG × Conductors | Max. DC R @ 20 °C Ω/km | Current in air A | Installed / duty A |
|---|---|---|---|
| 18 AWG × 2C | 21.400 | 10 | 8 |
| 18 AWG × 2C Limp | 21.400 | 10 | 8 |
| 18 AWG × 3C | 21.400 | 10 | 8 |
| 18 AWG × 3C Limp | 21.400 | 10 | 8 |
| 17 AWG × 3C | 16.900 | 12 | 10 |
| 16 AWG × 2C | 13.500 | 13 | 10 |
| 16 AWG × 3C | 13.500 | 13 | 10 |
| 16 AWG × 3C Limp | 13.500 | 13 | 10 |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| 1.5 kV AC dielectric test, spark test & DC resistance | Zero breakdown; resistance per UL 62 | 100 % of reels |
| Sample tests | ||
| Insulation/jacket wall check, tensile & -20 °C cold bend | Meets UL 62 Table 15 SVT wall and bend requirements | Every lot |
| UL VW-1 / CSA FT2 flame & appliance flex-life test | UL Listed & CSA Certified to UL 62 / C22.2 No. 49 | Type qualification |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.