UL 62 / CSA C22.2 No. 49 North American Thermoplastic & TPE Portable Cords300 V UL 62 / CSA Type SVT18 AWG & 16 AWG (2C / 3C)Compact 6.0–7.0 mm Round Profile

SVT Appliance Cord300 V UL 62 / CSA light-duty round thermoplastic PVC vacuum & appliance cord (18–16 AWG, 2

Type SVT (Service Vacuum Thermoplastic) is a lightweight, compact 300 V round flexible appliance cord manufactured to UL 62 and CSA C22.2 No. 49. Built with fine-stranded ASTM B174 bare copper conductors in 18 AWG and 16 AWG (2 or 3 conductors, 0.38 mm / 15-mi

UL VW-1 / CSA FT2 Flame Retardant
41/34 AWG Ultra-Limp Vacuum Stranding
UL Listed / CSA Certified
Order designation
SVT 18/3 (41/34)
Nom. OD
6.30 mm
Copper mass
26.2 kg/km
Total mass ≈
56.0 kg/km
Min. bend R
25.2 mm
All sizes (8)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
300 V AC
UL 62 light-duty pendant & portable
Gauge range
18 AWG & 16 AWG
2 or 3 conductors (up to 13 A)
Wall profile
15 mil / 30 mil
0.38 mm insul · 0.76 mm PVC jacket
Outer diameter
5.9 to 6.8 mm
25 % slimmer than SJT / SJTOW
Operating temp
-20 to +60 / +10
60 °C, 75 °C, 90 °C & 105 °C grades
Min. bend radius
4 × cord OD
Retractable appliance cord reels

Typical values for this cable type, based on UL 62 / CSA C22.2 No. 49 / NEC Art. 400 — confirmed in the datasheet and quotation for your order.

Application fit

Is SVT right for your machine?

Specified for commercial and household upright/canister vacuum cleaners, hospital and dental equipment carts, computer/PDU power cords, audio/lighting pendants and compact spring-wind appliance reels.

Trailing & towing

Suitable

Smooth, low-friction round PVC jacket glides over carpets, furniture corners and commercial tile floors without snagging.

Motorised monospiral reel

Suitable

Slim 6.0–6.8 mm diameter packs 40 % more cord length onto internal vacuum and appliance spring reels than SJT.

Free-hanging vertical run

Suitable

Approved by NEC Table 400.4 for indoor pendant and portable appliance supply cords.

Furnace, kiln & high-temp zone

Not suitable

Designed for dry/damp indoor light-duty use; for outdoor wet or oily shop service specify SJTOW or SJTOOW.

SJTOW outdoor portable cord
Typical machinesCommercial & household vacuumsMedical, dental & laboratory cartsIT, server & office appliance cordsSmall kitchen & floor-care appliancesIndoor pendant lighting & displays

Construction

Layer by layer

Fine bunch-stranded bare copper (41/34 AWG on 18 AWG or 65/34 AWG on 16 AWG) + 0.38 mm (15 mil) thermoplastic PVC core insulation + paper/textile separator + 0.76 mm (30 mil) smooth thermoplastic PVC outer jacket.

1234
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Fine bunch-stranded copper (34/30 AWG wires)Extra-limp 41×34 AWG (or 16×30 AWG) on 18 AWG and 65×34 AWG (or 26×30 AWG) on 16 AWG per UL 62ASTM B174
2Thin-wall thermoplastic PVC (15 mil)0.38 mm (0.015 in) colour-coded PVC insulation (Black, White, Green or Blue, Brown, Green/Yellow)UL 62
3Paper / fibrillated separator tissueAllows the outer PVC jacket to strip cleanly for high-speed moulded plug terminationUL 62
4Smooth appliance-grade PVC jacket (30 mil)0.76 mm (0.030 in) non-marking, low-friction PVC outer jacket in Black, White, Grey or custom OEM Pantone coloursUL 62

SVT 18/2 & 18/3 Vacuum Grade (41/34 AWG Extra-Limp Stranding)

Ultra-supple 34 AWG strand construction engineered specifically for commercial vacuum cleaners and spring cord rewinders.

SVT 105 °C OEM & Medical Power Cord Grade (18/3 & 16/3)

105 °C VW-1 / FT2 rated SVT with North American (Black/White/Green) or International (Brown/Blue/Green-Yellow) core colours.

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on UL 62 / CSA C22.2 No. 49 / NEC Art. 400. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage
300 V AC rms
Dielectric withstand test
1.5 kV AC rms for 1 minute
NEC ampacity (Table 400.5(A)(1))
10 A (18/2, 18/3) · 13 A (16/2, 16/3)

Thermal

Continuous temperature rating
+60 °C, +75 °C, +90 °C or +105 °C per UL 62
Cold bend temperature
-20 °C standard

Mechanical

Min. average insulation thickness
0.38 mm (15 mil) on 18 AWG & 16 AWG
Min. average jacket thickness
0.76 mm (30 mil) on 18 AWG & 16 AWG

Resistance

Flame retardancy
UL 1581 VW-1 vertical flame & CSA FT2 horizontal flame
Surface finish
Non-marring low-friction gloss or matte PVC

Reference standards

Governing standards
UL 62, CSA C22.2 No. 49 & NEC Article 400
Environmental compliance
UL Listed, CSA Certified, RoHS 3 & REACH compliant

Identification

Code breakdown
S = Service · V = Vacuum / Light Duty (300 V) · T = Thermoplastic PVC
Core colour options
NEMA (Black, White, Green) or International (Brown, Blue, Green/Yellow)

Sizes

8 standard configurations (SVT)

Nominal dimensions, copper weight, total mass and electrical parameters for SVT per UL 62 / CSA C22.2 No. 49 / NEC Art. 400.

Dimensions & masses
DesignationAWG × ConductorsStranding / NEC AmpsNom. OD
mm
Copper
kg/km
Total mass ≈
kg/km
Min. bend R
mm
Enquiry
SVT size schedule
SVT 18/2 (16/30)18 AWG × 2C16/30 · 10 A5.9017.544.023.6
SVT 18/2 (41/34)18 AWG × 2C Limp41/34 · 10 A5.9017.544.023.6
SVT 18/3 (16/30)18 AWG × 3C16/30 · 10 A6.3026.256.025.2
SVT 18/3 (41/34)18 AWG × 3C Limp41/34 · 10 A6.3026.256.025.2
SVT 17/317 AWG × 3C21/30 · 12 A6.5533.065.026.2
SVT 16/2 (26/30)16 AWG × 2C26/30 · 13 A6.4027.858.025.6
SVT 16/3 (26/30)16 AWG × 3C26/30 · 13 A6.8041.774.027.2
SVT 16/3 (65/34)16 AWG × 3C Limp65/34 · 13 A6.8041.774.027.2
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Dimensions and tolerances conform to UL 62 / CSA C22.2 No. 49 / NEC Art. 400.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
1.5 kV AC dielectric test, spark test & DC resistanceZero breakdown; resistance per UL 62100 % of reels
Sample tests
Insulation/jacket wall check, tensile & -20 °C cold bendMeets UL 62 Table 15 SVT wall and bend requirementsEvery lot
UL VW-1 / CSA FT2 flame & appliance flex-life testUL Listed & CSA Certified to UL 62 / C22.2 No. 49Type qualification

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

UL Listed Type SVT (300 V)CSA Certified C22.2 No. 49 (FT2 / VW-1)NEC Article 400 CompliantRoHS 3 & REACH Compliant

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX (UL) E-FILE SVT [N/AWG] 300V 105C VW-1 CSA LL-FILE SVT FT2 [lot/ft]
Delivery form
Non-returnable wooden drums, export reels or shrink-wrapped coils
Standard drum lengths
100 m · 250 m · 500 m · 1000 m
MOQ
200 m (stock sizes) · 500 m (custom lengths)
Lead time
2–3 weeks ex-works
Incoterms
EXW, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-20
Updated
2026-10-20

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

How does SVT differ from SJT (or SJTOW) in wall thickness and diameter?
Both SVT and SJT are 300 V round thermoplastic cords, but SVT uses half the insulation thickness (15 mil / 0.38 mm vs 30 mil / 0.76 mm) and half the jacket thickness (30 mil / 0.76 mm vs 60 mil / 1.52 mm). As a result, 18/3 SVT has an outer diameter of only ~6.3 mm versus ~7.9 mm for 18/3 SJT—reducing cross-sectional area by 36 %.
Why is SVT offered with 41/34 AWG stranding in addition to standard 16/30 AWG?
Commercial vacuum cleaners and floor-care appliances require a cord that coils effortlessly into a user's hand without kinking. Using 41 strands of ultra-fine 34 AWG copper wire instead of 16 strands of 30 AWG wire dramatically lowers flexural stiffness and extends plug-neck flex life.
What gauge sizes are permitted for Type SVT under UL 62?
Under UL 62 and CSA C22.2 No. 49, Type SVT is restricted to 18 AWG, 17 AWG and 16 AWG in 2-conductor and 3-conductor constructions. For 14 AWG and larger, specify SJT, SJTOW or SJTOOW.
Is SVT available in hospital-grade or custom Pantone appliance colours?
Yes. We extrude SVT in hospital-grade grey, pure white, matte black, high-visibility commercial-vacuum orange/yellow and custom OEM appliance colours.

Request a quote

Get an engineering quote for SVT

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

SVT Appliance Cord

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote