Power connection cablePower connection cableOrder-specific design

Center-Pivot Span Irrigation Pump CablePower connection for submerged pumps and water-handling equipment. Select insulation, sheath and cable entry for the actual liquid and installation.

Power connection for submerged pumps and water-handling equipment. Select insulation, sheath and cable entry for the actual liquid and installation.

Water-resistant
Order designation
Center-Pivot Span Irrigation Pump Cable
Rated voltage
600 V
Insulation
Polymer insulation
Outer sheath
Application-specific polymer
Core arrangement
Power and signal elements
All sizes (1)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
600 V
Temperature limit
—
Conductor
Stranded copper
Insulation
Polymer
Polymer insulation
Outer sheath
Polymer
Application-specific polymer
Core arrangement
Power / signal
Power and signal elements

Typical values for this cable type, based on Order-specific design — confirmed in the datasheet and quotation for your order.

Application fit

Is Center-Pivot Span Irrigation Pump Cable right for your machine?

Power connection for submerged pumps and water-handling equipment. Select insulation, sheath and cable entry for the actual liquid and installation.

Fixed installation

Suitable

Designed around the specified installation; select supports, bend protection and terminations together.

Immersion & wet locations

With conditions

Depth, pressure, fluid and temperature must be specified for immersion service.

Free-hanging vertical run

With conditions

Support and allowable suspended load are determined for the actual cable construction.

Cylindrical / multi-layer drum

With conditions

Repeated bending needs separate fatigue data; a flexible construction alone does not establish a cycle rating.

Typical machinesWater and wastewaterAgricultureIndustrial pumping

Construction

Layer by layer

Representative schematic; not to scale. The final core arrangement and dimensions follow the agreed drawing.

Layered cable cutaway
Layer cutaway
#LayerMaterial & reference
1ConductorStranded copper
2InsulationPolymer insulation
3Outer sheathApplication-specific polymer

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on Order-specific design. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage
600 V

Mechanical

Service profile
Fixed installation with installation flexing

Resistance

Water exposure
Specify depth, pressure and water chemistry
Chemical compatibility
Verify against the actual fluid and temperature

Reference standards

Design reference
Order-specific design

Identification

Core identification
To the agreed construction drawing
Sheath colour
To the agreed construction drawing

Sizes

Configuration and materials

Conductor size, dimensions and electrical loading are determined for the order. No size is implied by the illustration.

Selection reference
ConfigurationRated voltageInsulationOuter sheathCore arrangement
Center-Pivot Span Irrigation Pump Cable600 VPolymer insulationApplication-specific polymerPower and signal elements
  • This reference row describes a construction, not an orderable size. Provide the required core count and cross-section with the enquiry.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

Power connection cableCE · LVDRoHS · REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

Technical documents

Downloads

Revision
2026-10-30
Updated
2026-10-30

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What information is needed for selection?
State the application, circuit arrangement, required length and termination interfaces. For electrical circuits, include supply voltage, motor current and conductor size. Also describe fluid exposure, operating temperature, installation loads and any repeated movement. These inputs define the construction and the checks needed for the quoted configuration.
Do the illustrations define the supplied dimensions?
The gallery shows representative construction and is not drawn to scale. It does not define a supplied diameter, core size, connector interface or weight. Use the agreed construction drawing and order-specific technical schedule for installation clearances, terminations and handling calculations. Unverified dimensional values are deliberately left empty.
How are immersion and chemical conditions assessed?
Identify the actual medium, pressure, temperature and exposure duration rather than relying on a general water-resistant description. Include cleaning fluids, hydrocarbons or dissolved gases where relevant. Cable ends, joints and connector seals must be assessed with the cable. A material name alone does not establish a qualified immersion system.
Does a standard reference confirm product certification?
A design reference identifies the cable family or a relevant engineering method. It does not transfer another product’s certification, pressure qualification, drinking-water approval or hazardous-area rating. Required certificates and test scope must identify the exact supplied construction and assembly. Request these requirements explicitly so they can be addressed in the quotation.
Which technical documents are available?
Reference files are provided for project screening. Final parameters and the applicable document package are confirmed during quotation.

Request a quote

Get an engineering quote for Center-Pivot Span Irrigation Pump Cable

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

Center-Pivot Span Irrigation Pump Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp