SANS 1507 SWA 0.6/1 kV Armoured Mining Power CableSANS 1507 SWA 0.6/1 kV underground mining and industrial feeder cable per SANS 1507-3/4, comprising Class 2 copper conductors, 90 °C XLPE insulation, PVC bedding, galvanized round steel wire armour (SWA/ECC) and red-striped FR-PVC sheath.

Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per SANS 1507-3 / SANS 1507-4 / IEC 60502-1 across -15 to +90 °C.

Flame-retardant
Outdoor & humid
Ozone, UV & moisture
Approved
Order designation
SANS 1507 SWA 4×70 mm²
Outer Ø ≈
38.4 mm
Net weight ≈
3,890 kg/km
Tensile rating ≈
48.0 kN
Core / stranding
Class 2 plain Cu
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
0.6/1 kV
0.6/1 kV & 1.9/3.3 kV feeder duty
Operating temp.
-15 to +90 °C
Continuous mining & industrial duty
Min. bend radius
12 × OD
Fixed installation / dynamic routing
Core / conductor
4×35–185 mm² Cu
SANS 1411-1 Class 2 stranded copper
Outer protection
FR-PVC + SWA
Round SWA + red-striped FR-PVC jacket
Standard
SANS 1507
SANS 1507-3 / SANS 1507-4 / IEC 60502-1

Typical values for this cable type, based on SANS 1507-3 / SANS 1507-4 / IEC 60502-1 — confirmed in the datasheet and quotation for your order.

Application fit

Is SANS 1507 SWA right for your machine?

Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per SANS 1507-3 / SANS 1507-4 / IEC 60502-1 across -15 to +90 °C.

Mine roadway & tunnel wall hangers

Suitable

Engineered for underground mining shafts, galleries and tunnel infrastructure per SANS 1507-3 / SANS 1507-4 / IEC 60502-1.

Fixed installation

Suitable

Suitable for vertical shaft cleats, gallery messenger hooks and tray routing within 12 × OD.

Free-hanging vertical run

Suitable

Supports inclined roadway and vertical mine shaft suspension within rated kN load across -15 to +90 °C.

Typical machinesMining & TunnellingUnderground Coal & Hard-Rock MiningOpen-Cast Excavators, Draglines & ShovelsVertical Mine Shafts, Hoists & BoreholesTunneling, Mineral Processing & Slurry Plants

Construction

Layer by layer

Shown: SANS 1507 SWA (SANS 1507-3 / SANS 1507-4 / IEC 60502-1) featuring phase conductors (4×70 mm²), core insulation (xlpe / pvc) and red-striped flame-retardant sheath (5-layer construction).

12345
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Phase Conductors (4×70 mm²)SANS 1411-1 / IEC 60228 Class 2 stranded annealed plain copper
2Core Insulation (XLPE / PVC)90 °C XLPE insulation color-coded Red, Yellow, Blue & Black per SANS 1507
3Extruded PVC BeddingContinuous grey PVC inner bedding layer cushioning the 4-core assembly
4Round Steel Wire Armour / ECC (SWA)Galvanized round steel wires serving as mechanical armour & earth continuity
5Red-Striped Flame-Retardant SheathBlack UV-stabilized FR-PVC outer jacket with longitudinal red stripes

SANS 1507 SWA — Standard Mining Execution

Built to SANS 1507-3 / SANS 1507-4 / IEC 60502-1 with phase conductors (4×70 mm²) and red-striped flame-retardant sheath

SANS 1507 SWA — Custom Drum Length & Gland Kit

Available in custom shaft/roadway drum lengths or pre-terminated assemblies

SANS 1507 SWA — Routine & Flame Test Certified

Supplied with EN 10204 3.1 routine dielectric, resistance & flame test report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on SANS 1507-3 / SANS 1507-4 / IEC 60502-1. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
0.6/1 kV (SANS 1507-3 / SANS 1507-4 / IEC 60502-1)
Core / conductor construction
Phase Conductors (4×70 mm²) — SANS 1411-1 / IEC 60228 Class 2 stranded annealed plain copper
Primary dielectric / buffering
Core Insulation (XLPE / PVC) — 90 °C XLPE insulation color-coded Red, Yellow, Blue & Black per SANS 1507

Thermal

Continuous operating temperature
-15 to +90 °C (mining & industrial service)
Short-circuit / peak thermal rating
Verified thermal stability per SANS 1507-3 / SANS 1507-4 / IEC 60502-1
Storage & transport temperature
−40…+80 °C on export wooden/steel drum

Mechanical

Outer protection / armouring
Red-Striped Flame-Retardant Sheath — Black UV-stabilized FR-PVC outer jacket with longitudinal red stripes
Minimum bending radius
12 × OD
Crush, impact & abrasion duty
Heavy-duty mining rock-cut, impact and tensile protection per SANS 1507-3 / SANS 1507-4 / IEC 60502-1

Resistance

Flame retardancy & mine fire safety
Self-extinguishing / flame-retardant mining jacket per SANS 1507-3 / SANS 1507-4 / IEC 60502-1
Mine water, oil & chemical resistance
Resistant to acidic mine water, hydraulic oils and abrasion per SANS 1507-3 / SANS 1507-4 / IEC 60502-1
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
SANS 1507-3 / SANS 1507-4 / IEC 60502-1
Flame & environmental test standards
IEC 60332 / MSHA / EN 60794 / IEC 60228
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
SANS 1507 SWA
Sheath colour & metre marking
Continuous metre-marked black mining outer sheath
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard SANS 1507 SWA mining & industrial configurations

Manufactured to SANS 1507-3 / SANS 1507-4 / IEC 60502-1 for underground mining, open-cast excavation, shaft and heavy industrial systems.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Tensile rating
kN ≈
Min. bend R
mm
Enquiry
SANS 1507 SWA Construction Schedule (-15 to +90 °C)
SANS 1507 SWA 4×35 mm²4 × 35 mm² + SWA ECCClass 2 plain Cu29.82,18028.0360
SANS 1507 SWA 4×70 mm²4 × 70 mm² + SWA ECCClass 2 plain Cu38.43,89048.0460
SANS 1507 SWA 4×120 mm²4 × 120 mm² + SWA ECCClass 2 plain Cu47.66,24072.0570
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour grades and factory drum lengths available per SANS 1507-3 / SANS 1507-4 / IEC 60502-1.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, continuity & dimensional verification (SANS 1507-3 / SANS 1507-4 / IEC 60502-1)DC resistance at 20 °C / optical attenuation and outer diameter within SANS 1507-3 / SANS 1507-4 / IEC 60502-1 tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (SANS 1507-3 / SANS 1507-4 / IEC 60502-1)Zero dielectric breakdown and verified insulation resistance over full production lengthEvery manufactured drum length
Sample tests
Flame propagation, mechanical crush & thermal ageing qualification (SANS 1507-3 / SANS 1507-4 / IEC 60502-1)Verified flame retardancy, mechanical integrity and thermal endurance across -15 to +90 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

SANS 1507 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX SANS 1507 SWA SANS 1507 0.6/1 kV CE
Delivery form
Heavy-duty export fumigated wooden drums or steel mine reels
Standard lengths
500 m, 1,000 m or custom continuous shaft/reeling lengths
MOQ
100 m (standard configurations) · 500 m (custom builds)
Lead time
2–5 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-24
Updated
2026-10-24

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define SANS 1507 SWA (SANS 1507 SWA 0.6/1 kV Armoured Mining Power Cable)?
SANS 1507 SWA (SANS 1507 SWA 0.6/1 kV Armoured Mining Power Cable) is manufactured in accordance with SANS 1507-3 / SANS 1507-4 / IEC 60502-1 for 0.6/1 kV duty over -15 to +90 °C. Its 5-layer construction comprises Phase Conductors (4×70 mm²), Core Insulation (XLPE / PVC) and Red-Striped Flame-Retardant Sheath.
What is the minimum bending radius and operating temperature range for SANS 1507 SWA?
The minimum bending radius for SANS 1507 SWA is 12 × OD across its continuous operating temperature range of -15 to +90 °C, ensuring mechanical and dielectric reliability in mining and heavy industrial service.
How are the concentric layers of SANS 1507 SWA arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Phase Conductors (4×70 mm²) (SANS 1411-1 / IEC 60228 Class 2 stranded annealed plain copper); (02) Core Insulation (XLPE / PVC) (90 °C XLPE insulation color-coded Red, Yellow, Blue & Black per SANS 1507); (03) Extruded PVC Bedding (Continuous grey PVC inner bedding layer cushioning the 4-core assembly); (04) Round Steel Wire Armour / ECC (SWA) (Galvanized round steel wires serving as mechanical armour & earth continuity); (05) Red-Striped Flame-Retardant Sheath (Black UV-stabilized FR-PVC outer jacket with longitudinal red stripes).
What factory test certificates are supplied with SANS 1507 SWA?
Every production drum of SANS 1507 SWA undergoes routine conductor resistance/continuity, high-voltage dielectric and dimensional testing per SANS 1507-3 / SANS 1507-4 / IEC 60502-1, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for SANS 1507 SWA

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

SANS 1507 SWA 0.6/1 kV Armoured Mining Power Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote