YGCR 0.6/1 kV 180 °C Extra-Flexible Silicone Power CableExtra-flexible Class 6 silicone rubber 0.6/1 kV mobile high-temp cable

YGCR 0.6/1 kV Flexible upgrades YGC with ultra-flexible Class 6 bare copper stranding and a tough grey 180 °C halogen-free silicone outer sheath for moving furnace cranes, foundry trolleys, and vibrating hot equipment.

Flame-retardant
Oil-resistant
Approved
Order designation
YGCR 0.6/1 kV Flexible Cable 4G10 mm²
Outer Ø
18.6 mm
Max. R20
1.910 Ω/km
Weight
861 kg/km
Min. bend R
140 mm
All sizes (9)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
0.6/1 kV
Test voltage 3.5 kV AC
Temp. (fixed)
-60°C…+180°C
Flexing: -35 °C to +180 °C
Construction
SiR
Extra-flexible 180 °C halogen-free
Min. bend radius
7.5 × OD
High-current flexible routing
Conductor
Bare Cu · Cl.6
Per JB/T 8734 (ref.)
Size range
3G2.5–4G50
9 standard configurations

Typical values for this cable type, based on JB/T 8734 (ref.) · IEC 60228 Class 6 · IEC 60754-1 Halogen-Free — confirmed in the datasheet and quotation for your order.

Application fit

Is YGCR 0.6/1 kV Flexible Cable right for your machine?

YGCR 0.6/1 kV Flexible upgrades YGC with ultra-flexible Class 6 bare copper stranding and a tough grey 180 °C halogen-free silicone outer sheath for moving furnace cranes, foundry trolleys, and vibrating hot equipment.

Furnace, kiln & high-temp zone

Suitable

Thermal-rated 0.6/1 kV SiR build delivers stable high-current power near furnaces, ovens, kilns, and molten-metal zones.

Fixed installation

Suitable

Durable 0.6/1 kV SiR geometry installs cleanly along transformer links, busbar transitions, trays, and industrial bays.

High-temperature boiler & thermal plant

Suitable

Thermal-aged 0.6/1 kV SiR insulation maintains dielectric safety near industrial boilers, ovens, and high-ambient thermal equipment.

Cable trench & heavy drive bay

Suitable

Rugged 0.6/1 kV SiR construction handles stationary heavy-plant cable trenches, rolling-mill feeders, and industrial power bays.

Energy chain / drag chain

Not suitable

0.6/1 kV SiR construction is built for stationary or light-flex runs, not continuous high-cycle drag-chain flexing.

Use (N)12YRDC11Y-J/O PUR

Immersion & wet locations

Not suitable

0.6/1 kV SiR outer sheath is not AD8-rated for permanent water submersion; specify a submersible EPDM or water-blocked cable.

Use EMC-VFD Submersible EPDM
Typical machinesSteelworks, rolling mills & aluminum smeltersIndustrial ovens, ceramic kilns & glassworksCommercial heating elements & cartridge heatersPower plants, boiler rooms & hot switchgear

Construction

Layer by layer

Representative construction of YGCR 0.6/1 kV Flexible Cable: IEC 60228 Class 6 extra-flexible bare annealed copper, Extra-flexible 180 °C halogen-free silicone rubber core insulation, and Grey abrasion- & heat-resistant halogen-free silicone outer sheath.

123
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1ConductorIEC 60228 Class 6 extra-flexible bare annealed copperIEC 60228 Class 6
2Cooling core / primary dielectricExtra-flexible 180 °C halogen-free silicone rubber core insulationJB/T 8734 (ref.)
3Outer sheath / hoseGrey abrasion- & heat-resistant halogen-free silicone outer sheathClass 6 Extra-Flexible

YGCR 0.6/1 kV Flexible Cable Multi-Element

Multi-element core assembly with color-coded conductors and protective heavy-duty outer sheath.

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on JB/T 8734 (ref.) · IEC 60228 Class 6 · IEC 60754-1 Halogen-Free. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage
0.6/1 kV
Test voltage
3.5 kV AC
Conductor
Bare Cu · Cl.6
Core / dielectric
Extra-flexible 180 °C halogen-free
Impedance / insulation
≥ 1,000 MΩ·km at 20 °C

Thermal

Temp. range (fixed)
-60 °C to +180 °C
Temp. range (flexing)
-35 °C to +180 °C
Peak / short-circuit
+250 °C (short-term)
Min. bending radius
7.5 × OD

Resistance

Primary performance
Class 6 Extra-Flexible
Environment / duty
180 °C Continuous Silicone
Mechanical / special
Thermal-Shock & Ozone Proof
Outer finish
Grey abrasion- & heat-resistant

Sizes

0.6/1 kV 180 °C Silicone Power (mm²)
Cores ×
mm²
Outer Ø ≈
mm
Max. R20
Ω/km
Copper index
kg/km
Weight ≈
kg/km
Min. bend R
7.5×D mm
3G2.5 mm²10.67.9807220380
4G2.5 mm²11.67.9809625887
4G4 mm²13.44.950154381100
4G6 mm²15.23.300230537114
4G10 mm²18.61.910384861140
4G16 mm²21.81.2106141,309164
4G25 mm²26.20.7809601,996196
4G35 mm²29.80.5541,3442,730224
4G50 mm²34.60.3861,9203,838260
  • Conductor DC resistance R20 at 20 °C per IEC 60228 Class 6.
  • Minimum bending radius calculated at 7.5 × nominal outer diameter (OD). Custom terminations available on request.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
High-voltage dielectric withstand test3.5 kV AC without breakdownEvery manufactured length
Continuity & conductor DC resistancePer IEC 60228 Class 6 at 20 °CEvery drum / assembly
Sample tests
Tensile, dimensional & pressure checkRated -60 °C to +180 °C continuousPer production lot
Environmental, thermal & mechanical qualificationClass 6 Extra-Flexible · 180 °C Continuous SiliconeType approval

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

JB/T 8734 (ref.)IEC 60228 Class 6IEC 60754-1 Halogen-FreeEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

YGCR 0.6/1 kV Flexible Cable 0.6/1 kV TEBAOFLEX.COM [JB/T 8734 (ref.)] [Size] [Metre mark]
Delivery form
Custom assemblies, coils or export drums
Standard lengths
Cut-to-length · 100 m · 500 m · 1,000 m
MOQ
1 assembly / 50 m (stock) · 300 m (custom)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-11-23
Updated
2026-11-23

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What makes YGCR 0.6/1 kV Flexible Cable suited for demanding 0.6/1 kV installations?
YGCR 0.6/1 kV Flexible Cable combines IEC 60228 Class 6 extra-flexible bare annealed copper with Extra-flexible 180 °C halogen-free silicone rubber core insulation and Grey abrasion- & heat-resistant halogen-free silicone outer sheath. Class 6 fine-wire stranding and elastic silicone sheath handle repeated flexing in hot foundry zones.
What minimum bending radius should be respected for YGCR 0.6/1 kV Flexible Cable?
Maintain a minimum bending radius of 7.5 × OD across -35 °C to +180 °C flexing temperatures to ensure long mechanical and dielectric service life.
Can YGCR 0.6/1 kV Flexible Cable be delivered pre-terminated with custom lugs, water fittings, or subsea connectors?
Yes. TEBAOFLEX supplies YGCR 0.6/1 kV Flexible Cable either in bulk lengths or factory-assembled with copper lugs, water-cooled swivel fittings, or molded subsea wet-mate connectors.
What quality tests and certificates accompany every shipment of YGCR 0.6/1 kV Flexible Cable?
YGCR 0.6/1 kV Flexible Cable conforms to JB/T 8734 (ref.), IEC 60228 Class 6, IEC 60754-1 Halogen-Free (Class 6 Extra-Flexible) and ships with an EN 10204 3.1 routine factory test certificate.
Which technical documents are available?
Reference files are provided for project screening. Final parameters and the applicable document package are confirmed during quotation.

Request a quote

Get an engineering quote for YGCR 0.6/1 kV Flexible Cable

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

YGCR 0.6/1 kV 180 °C Extra-Flexible Silicone Power Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote