V75 / V90 HD/LD Flexible Cord 250/440V–0.6/1kV AS/NZS 3191V75 / V90 HD/LD Flexible Cord 250/440V–0.6/1kV AS/NZS 3191 manufactured to AS/NZS 3191 / AS/NZS 1125, rated 250/250 V / 250/440 V / 0.6/1 kV and -20°C to +75°C with a 6 × OD minimum bending radius for industrial automation & manufacturing installations.

Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.

Flame-retardant
Oil-resistant
Approved
Order designation
V75 / V90 HD/LD Flexible Cord 250/440V–0.6/1kV (3G4 mm²)
Outer diameter
13.5 mm
Cable weight
428 kg/km
Min. bend radius
81 mm
Conductor & shield
Class 5 Flexible Plain Copper
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
250/250–0.6/1 kV
AS/NZS 3191 / AS/NZS 1125
Temperature
-20°C to +75°C
Fixed / flex duty
Min. bend radius
6 × OD
13.5–18.6 mm
Screening
Unshielded
Fixed / flex duty
Outer sheath
Industrial PVC
Oil & sunlight resistant
Core / size range
3 sizes
3 standard configurations

Typical values for this cable type, based on Reference specification per AS/NZS 3191 / AS/NZS 1125 (V75 / V90 HD/LD Flexible Cord 250/440V–0.6/1kV) — confirmed in the datasheet and quotation for your order.

Application fit

Is V75 / V90 HD/LD Flexible Cord 250/440V–0.6/1kV right for your machine?

Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.

Fixed installation

Suitable

Approved for cable tray, duct, direct burial or clipped fixed installations per applicable wiring regulations.

Motor stator, traction & converter leads

Suitable

Flexible stranded conductors withstand equipment vibration, mobile hook-ups and routine flexing.

Energy chain / drag chain

With conditions

Fixed or moderate-flex construction; for continuous high-acceleration drag chains, select a dedicated Class 6 chain cable.

Offshore platform & shipboard deck trays

Suitable

Outer sheath compound resists industrial oils, moisture ingress, abrasion and outdoor weathering.

Vertical / spreader reel

Not suitable

Not intended for high-tension crane spreader reeling drums; select a dedicated 2PNCT or 3PNCT reeling cable.

Use TRA 0.6/1 kV PUR Reeling Cable

Dual-tier power & PLC tray

Suitable

Screened 0.6/1 kV PVC construction suppresses electromagnetic interference on shared industrial power and PLC signal trays.

Typical machinesIndustrial Automation CablePower distribution & utility networksRailways, tunnels & public infrastructureProcess instrumentation & oil/gas skidsIndustrial automation & control cabinetsRenewable energy, marine & heavy industry

Construction

Layer by layer

Cross-section colours are aligned to the supplied product cutaway; layer dimensions follow the reference specification.

V75 / V90 HD/LD Flexible Cord 250/440V–0.6/1kV – Layered cable cutaway
Layer cutaway
#LayerMaterial & reference
1Conductor3G4.0 mm² (56/0.30 mm) Flexible Cu
2Insulation & Core IdentificationAS/NZS 3191 V-90 PVC core insulation (4.0 mm² Flexible Copper)
3Screen / Bedding / Armour Layer3-core flexible circular lay-up (Brown, Light Blue, Green/Yellow) for heavy-duty cord flexing
4Outer Protective SheathOrange heavy-duty 5V-90 PVC flexible cord outer sheath (OD 13.5 mm)

3G4 mm²

Class 5 Flexible Plain Copper · Outer diameter 13.5 mm

3G6 mm²

Class 5 Flexible Plain Copper · Outer diameter 15.9 mm

3G10 mm²

Class 5 Flexible Plain Copper · Outer diameter 18.6 mm

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on Reference specification per AS/NZS 3191 / AS/NZS 1125 (V75 / V90 HD/LD Flexible Cord 250/440V–0.6/1kV). Values for your order are confirmed in the datasheet and quotation.

Electrical

Nominal / reference voltage
250/250 V / 250/440 V / 0.6/1 kV
Conductor & core insulation
3G4.0 mm² (56/0.30 mm) Flexible Cu · AS/NZS 3191 V-90 PVC core insulation (4.0 mm² Flexible Copper)
Routine dielectric / continuity test
100% factory drum spark & continuity verified

Thermal

Operating temperature range
-20°C to +75°C
Short-circuit / peak thermal limit
+160 °C to +250 °C (5 s conductor thermal limit)
Flame & fire performance
AS/NZS 3191 / AS/NZS 1125

Mechanical

Minimum bending radius
6 × OD
Screening / armour architecture
3-core flexible circular lay-up (Brown, Light Blue, Green/Yellow) for heavy-duty cord flexing
Outer sheath material & colour
Orange heavy-duty 5V-90 PVC flexible cord outer sheath (OD 13.5 mm)

Reference standards

Reference standard
AS/NZS 3191 / AS/NZS 1125
Hazardous Substance Compliance
CE, UKCA, RoHS 2 (2011/65/EU) & REACH SVHC compliant
Quality & Batch Traceability
EN 10204 3.1 Factory Inspection Certificate

Sizes

Sizes & engineering data

Representative configurations from the series specification; select a row to prefill the quotation tool.

All sizes
ConfigurationConductor & shieldInsulation / wallOuter sheathOuter diameter
mm
Min. bend radius
mm
Max. conductor resistance @ 20 °C
Ω/km
Copper weight
kg/km
Cable weight
kg/km
Key electrical / optical ratingPart designationEnquiry
V75 / V90 HD/LD Flexible Cord 250/440V–0.6/1kV
3G4 mm²Class 5 Flexible Plain CopperAS/NZS 3191 V-90 PVC core insulationIndustrial PVC13.5814.53222.642834 AV75 / V90 HD/LD Flexible Cord 250/440V–0.6/1kV (3G4 mm²)
3G6 mm²Class 5 Flexible Plain CopperAS/NZS 3191 V-90 PVC core insulationIndustrial PVC15.9953.02309.959643 AV75 / V90 HD/LD Flexible Cord 250/440V–0.6/1kV (3G6 mm²)
3G10 mm²Class 5 Flexible Plain CopperAS/NZS 3191 V-90 PVC core insulationIndustrial PVC18.61121.81424.381660 AV75 / V90 HD/LD Flexible Cord 250/440V–0.6/1kV (3G10 mm²)
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Dimensions and weights are nominal manufacturing targets subject to standard production tolerances.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance & continuityWithin maximum Ω/km limit at 20 °C per IEC 60228 / BS EN 60228Every manufactured drum length
Dielectric withstand / spark testNo breakdown across insulation, screen or armourEvery manufactured drum length
Sample tests
Vertical flame propagation & jacket qualificationSelf-extinguishing and compliant with reference standard limitsType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

AS/NZS 3191 / AS/NZS 1125 CompliantEN 10204 3.1 Factory Test CertificateCE, UKCA, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

V75 / V90 HD/LD FLEXIBLE CORD 250/440V–0.6/1kV AS/NZS 3191 / TEBAOFLEX.COM — sequential metre marking
Delivery form
Heavy-duty export fumigated wooden drums or steel reels with moisture-sealed ends
Standard lengths
250 m, 500 m, 1000 m continuous drum lengths or custom cut-to-length runs
MOQ
100 m (standard configurations) · 300 m (custom builds)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-11-04
Updated
2026-11-04

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What applications is V75 / V90 HD/LD Flexible Cord 250/440V–0.6/1kV designed for?
V75 / V90 HD/LD Flexible Cord 250/440V–0.6/1kV is engineered for industrial automation & manufacturing installations under AS/NZS 3191 / AS/NZS 1125, operating over -20°C to +75°C with a minimum bending radius of 6 × OD.
How is V75 / V90 HD/LD Flexible Cord 250/440V–0.6/1kV constructed across its layers?
Its 4-layer architecture combines 3G4.0 mm² (56/0.30 mm) Flexible Cu with AS/NZS 3191 V-90 PVC core insulation (4.0 mm² Flexible Copper), 3-core flexible circular lay-up (Brown, Light Blue, Green/Yellow) for heavy-duty cord flexing and Orange heavy-duty 5V-90 PVC flexible cord outer sheath (OD 13.5 mm).
What standards and routine factory tests apply to V75 / V90 HD/LD Flexible Cord 250/440V–0.6/1kV?
Every manufactured drum is tested to AS/NZS 3191 / AS/NZS 1125 for conductor continuity, dielectric voltage withstand and sheath integrity, supplied with an EN 10204 3.1 inspection certificate.
What sizes and drum lengths are available for V75 / V90 HD/LD Flexible Cord 250/440V–0.6/1kV?
Representative sizes include 3G4 mm², 3G6 mm² and 3G10 mm², supplied on 250 m, 500 m or 1,000 m export drums or custom cut lengths.
Which technical documents are available?
Reference files are provided for project screening. Final parameters and the applicable document package are confirmed during quotation.

Request a quote

Get an engineering quote for V75 / V90 HD/LD Flexible Cord 250/440V–0.6/1kV

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

V75 / V90 HD/LD Flexible Cord 250/440V–0.6/1kV AS/NZS 3191

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote