Contact
wind turbine tower, DLO & blade grounding power cableDIN VDE 0276-604 / IEC 60502-10.6/1 kV (-35 to +90 °C)HM4 Halogen-Free Flame-Retardant Out

(N)A2XH 0.6/1 kV (4,000 V AC Test) DIN VDE 0276-604 Class 2 Aluminum 2XI1 XLPE / HM4 LSZH Wind Tower CableDIN VDE 0276-604 / IEC 60502-1 — 0.6/1 kV — -35 to +90 °C Wind Turbine Cable

(N)A2XH 0.6/1 kV (4,000 V AC Test) DIN VDE 0276-604 Class 2 Aluminum 2XI1 XLPE / HM4 LSZH Wind Tower Cable (DIN VDE 0276-604 / IEC 60502-1) engineered for 0.6/1 kV wind turbine service across -35 to +90 °C (min. bend radius 12 × OD).

Anti-torsion braid
Flame-retardant
Oil-resistant
Approved
Order designation
(N)A2XH 0.6/1 kV Alumi 1×150 / 4×95 Al
Outer Ø ≈
23.5 mm
Net weight ≈
640 kg/km
Max. pulling ≈
10.5 kN
Core / stranding
Class 2 Compacted Al / Class 5 AA8000
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
0.6/1 kV
Tested per DIN VDE 0276-604 / IEC 60502-
Operating temp.
−35…+90 °C
Cold-climate & nacelle wind service
Min. bend radius
12 × OD
Drip-loop, hub & tower routing
Core / conductor
Class 2 Stranded
DIN VDE 0295 Class 2 circular stranded a
Outer protection
HM4 Halogen-Free
Low-smoke zero-halogen polyolefin jacket
Standard
DIN VDE 0276-604
DIN VDE 0276-604 & IEC 60502-1 (N)A2XH 0

Typical values for this cable type, based on DIN VDE 0276-604 & IEC 60502-1 (N)A2XH 0.6/1 kV Halogen-Free Aluminum Tower Specification — confirmed in the datasheet and quotation for your order.

Application fit

Is (N)A2XH 0.6/1 kV Aluminum Tower right for your machine?

(N)A2XH 0.6/1 kV (4,000 V AC Test) DIN VDE 0276-604 Class 2 Aluminum 2XI1 XLPE / HM4 LSZH Wind Tower Cable (DIN VDE 0276-604 / IEC 60502-1) engineered for 0.6/1 kV wind turbine service across -35 to +90 °C (min. bend radius 12 × OD).

Fixed installation

Suitable

Compacted Class 2 aluminum or Class 5/K copper conductors with XLPE/EPR/HEPR insulation install cleanly in vertical tower cleats and trays

Free-hanging vertical run

Suitable

Flexible DLO 2 kV, WTTC 1 kV and blade grounding builds absorb nacelle yaw loop torsion and rotor blade flexing down to −40 °C.

Switchgear & control cabinet wiring

Suitable

NSGAFOU 1.8/3 kV short-circuit-proof and UL WTTC/RHW-2 feeders wire directly into nacelle converter cabinets and tower base switchgear.

Offshore platform & shipboard deck trays

Suitable

Heavy-duty CPE, HM4/HFFR LSZH and 5GM3 polychloroprene jackets resist turbine hydraulic oil, condensation, salt spray and UV.

Energy chain / drag chain

Not suitable

Wind tower power feeders and large-cross-section DLO cables are not intended for high-cycle factory drag chains.

Use Drag-Chain Servo Cable
Typical machinesRenewable Energy & EV ChargingWind Turbine Tower Vertical Power Feeders (Cu & Al)North American UL 2277 WTTC & 2 kV DLO Wind TurbinesIEC 61400-24 Wind Blade Lightning Down-ConductorsNacelle Converter Busbars & Transformer Interconnects

Construction

Layer by layer

Shown: (N)A2XH 0.6/1 kV Aluminum Tower (DIN VDE 0276-604 & IEC 60502-1 (N)A2XH 0.6/1 kV Halogen-Free Aluminum Tower Specification) featuring class 2 stranded aluminum conductor (25-300 mm² rm), 2xi1 cross-linked polyethylene (xlpe) insulation and hm4 halogen-free flame-retardant outer sheath (3-layer construction).

123
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Class 2 Stranded Aluminum Conductor (25-DIN VDE 0295 Class 2 circular stranded aluminum reducing tower weight
22XI1 Cross-Linked Polyethylene (XLPE) In90 °C XLPE dielectric tested at 4,000 VAC
3HM4 Halogen-Free Flame-Retardant Outer SLow-smoke zero-halogen polyolefin jacket for fixed tower cleats

(N)A2XH 0.6/1 kV Aluminum Tower — Standard Wind Turbine Execution

Built to DIN VDE 0276-604 & IEC 60502-1 (N)A2XH 0.6/1 kV Halogen-Free Aluminum Tower Specification with class 2 stranded aluminum conductor (25-300 mm² rm) and hm4 halogen-free flame-retardant outer sheath

(N)A2XH 0.6/1 kV Aluminum Tower — Pre-Cut Tower / Drip-Loop Kit

Available on bulk export reels or pre-cut to turbine tower section and nacelle drip-loop lengths

(N)A2XH 0.6/1 kV Aluminum Tower — Cold Torsion & Routine Certified

Supplied with EN 10204 3.1 routine dielectric, conductor DC resistance & cold-torsion qualification report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on DIN VDE 0276-604 & IEC 60502-1 (N)A2XH 0.6/1 kV Halogen-Free Aluminum Tower Specification. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / operating system
0.6/1 kV (DIN VDE 0276-604 & IEC 60502-1 (N)A2XH 0.6/1 kV Halogen-Free Aluminum Tower Specification)
Core / conductor construction
Class 2 Stranded Aluminum Conductor (25-300 mm² RM) — DIN VDE 0295 Class 2 circular stranded aluminum reducing tower weight
Primary dielectric / insulation
2XI1 Cross-Linked Polyethylene (XLPE) Insulation — 90 °C XLPE dielectric tested at 4,000 VAC

Thermal

Continuous operating temperature
−35…+90 °C (wind turbine nacelle, hub & tower duty)
Low-temperature torsion & cold bend
Verified cold-flex and torsion endurance across −35…+90 °C per DIN VDE 0276-604 & IEC 60502-1 (N)A2XH 0.6/1 kV Halogen-Free Aluminum Tower Specification
Storage & transport temperature
−40…+80 °C on export wooden/steel cable drum

Mechanical

Outer jacket / sheath protection
HM4 Halogen-Free Flame-Retardant Outer Sheath — Low-smoke zero-halogen polyolefin jacket for fixed tower cleats
Minimum bending radius
12 × OD
Intermediate screen / separator / core layer
2XI1 Cross-Linked Polyethylene (XLPE) Insulation — 90 °C XLPE dielectric tested at 4,000 VAC

Resistance

Oil, grease, ozone & UV resistance
Resistant to wind turbine gearbox oil, hydraulic fluid, ozone and UV weathering per DIN VDE 0276-604 & IEC 60502-1 (N)A2XH 0.6/1 kV Halogen-Free Aluminum Tower Specification
Flame retardancy & smoke/halogen emission
Flame-retardant and environmental performance verified per DIN VDE 0276-604 & IEC 60502-1 (N)A2XH 0.6/1 kV Halogen-Free Aluminum Tower Specification
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
DIN VDE 0276-604 & IEC 60502-1 (N)A2XH 0.6/1 kV Halogen-Free Aluminum Tower Specification
Conductor & flame/test standards
IEC 60228 / IEC 60332-1-2 & -3 / UL 2277 WTTC / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
(N)A2XH 0.6/1 kV Aluminum Tower
Sheath colour & metre marking
Continuous metre-marked black outer finish (HM4 Halogen-Free)
Customs tariff (HS)
8544.49 / 8544.60

Sizes

3 standard (N)A2XH 0.6/1 kV Aluminum Tower wind turbine configurations

Manufactured to DIN VDE 0276-604 & IEC 60502-1 (N)A2XH 0.6/1 kV Halogen-Free Aluminum Tower Specification for wind turbine yaw drip-loop, pitch control, tower power and converter applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Max. pulling
kN ≈
Min. bend R
mm
Enquiry
(N)A2XH 0.6/1 kV Aluminum Tower Construction Schedule (−35…+90 °C)
(N)A2XH 0.6/1 kV Alumi 1×150 / 4×95 Al1 × 150 mm² (or 4 × 95 mm² Al)Class 2 Compacted Al / Class 5 AA800023.564010.5190
(N)A2XH 0.6/1 kV Alumi 1×240 / 4×150 Al1 × 240 mm² (or 4 × 150 mm² Al)Class 2 Compacted Al / Class 5 AA800028.498016.8230
(N)A2XH 0.6/1 kV Alumi 1×400 / 4×240 Al1 × 400 mm² (or 4 × 240 mm² Al)Class 2 Compacted Al / Class 5 AA800035.81,59028.0290
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom conductor cross-sections, core counts, pre-lugged tower kits and drum lengths available per DIN VDE 0276-604 & IEC 60502-1 (N)A2XH 0.6/1 kV Halogen-Free Aluminum Tower Specification.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor DC resistance & dimensional verification (DIN VDE 0276-604 & IEC 60502-1 (N)A2XH 0.6/1 kV Halogen-Free Aluminum Tower Specification)DC resistance at 20 °C and insulation/sheath wall thickness within DIN VDE 0276-604 & IEC 60502-1 (N)A2XH 0.6/1 kV Halogen-Free Aluminum Tower Specification limitsEvery manufactured drum length
AC high-voltage dielectric & insulation resistance test (DIN VDE 0276-604 & IEC 60502-1 (N)A2XH 0.6/1 kV Halogen-Free Aluminum Tower Specification)Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV ratingEvery manufactured drum length
Sample tests
Low-temperature drip-loop torsion, oil & flame qualification (DIN VDE 0276-604 & IEC 60502-1 (N)A2XH 0.6/1 kV Halogen-Free Aluminum Tower Specification)Verified cold torsion cycle endurance, oil resistance and flame retardancy across −35…+90 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

DIN VDE 0276-604 / IEC 60502-1 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX (N)A2XH 0.6/1 kV Aluminum Tower DIN VDE 0276-604 / IEC 60502-1 0.6/1 kV CE
Delivery form
Heavy-duty export fumigated wooden drums, steel reels or pre-cut wind turbine tower & drip-loop kits
Standard lengths
500 m, 1,000 m or custom cut-to-length nacelle drip-loop and tower section sets
MOQ
100 m (standard configurations) · 300 m (custom wind builds)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-27
Updated
2026-10-27

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define (N)A2XH 0.6/1 kV Aluminum Tower ((N)A2XH 0.6/1 kV (4,000 V AC Test) DIN VDE 0276-604 Class 2 Aluminum 2XI1 XLPE / HM4 LSZH Wind Tower Cable)?
(N)A2XH 0.6/1 kV Aluminum Tower ((N)A2XH 0.6/1 kV (4,000 V AC Test) DIN VDE 0276-604 Class 2 Aluminum 2XI1 XLPE / HM4 LSZH Wind Tower Cable) is manufactured in accordance with DIN VDE 0276-604 & IEC 60502-1 (N)A2XH 0.6/1 kV Halogen-Free Aluminum Tower Specification for 0.6/1 kV wind turbine service over -35 to +90 °C. Its 3-layer construction comprises class 2 stranded aluminum conductor (25-300 mm² rm), 2xi1 cross-linked polyethylene (xlpe) insulation and hm4 halogen-free flame-retardant outer sheath.
What is the minimum bending radius and operating temperature range for (N)A2XH 0.6/1 kV Aluminum Tower?
The minimum bending radius for (N)A2XH 0.6/1 kV Aluminum Tower is 12 × OD across its continuous operating temperature range of -35 to +90 °C, ensuring mechanical torsion resistance and dielectric reliability in wind turbine nacelles, hubs and towers.
How are the concentric layers of (N)A2XH 0.6/1 kV Aluminum Tower arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Class 2 Stranded Aluminum Conductor (25-300 mm² RM) — DIN VDE 0295 Class 2 circular stranded aluminum reducing tower weight; (02) 2XI1 Cross-Linked Polyethylene (XLPE) Insulation — 90 °C XLPE dielectric tested at 4,000 VAC; (03) HM4 Halogen-Free Flame-Retardant Outer Sheath — Low-smoke zero-halogen polyolefin jacket for fixed tower cleats.
What factory test certificates are supplied with (N)A2XH 0.6/1 kV Aluminum Tower?
Every production drum of (N)A2XH 0.6/1 kV Aluminum Tower undergoes routine conductor DC resistance, AC high-voltage dielectric and dimensional testing per DIN VDE 0276-604 & IEC 60502-1 (N)A2XH 0.6/1 kV Halogen-Free Aluminum Tower Specification, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for (N)A2XH 0.6/1 kV Aluminum Tower

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

(N)A2XH 0.6/1 kV (4,000 V AC Test) DIN VDE 0276-604 Class 2 Aluminum 2XI1 XLPE / HM4 LSZH Wind Tower Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote