Offshore platform & shipboard deck trays
Halogen-free SHF1/SHF2, IEEE 1580 Type P or PE/PP submarine outer serving withstands marine salt mist, drilling mud and seabed/deck duty.
Product
IEEE 1580 Type P & UL 1309 600 V – 2,000 V Single-Core (1/C) Extra-Flexible Propulsion & Winch Feeder Cable (IEEE 1580 Type P / UL 1309) engineered for 600 V / 0.6/1 kV / 2 kV service across -40 to +125 °C (min. bend radius 6 × OD).
Typical values for this cable type, based on IEEE Std 1580 Type P & UL 1309 / CSA C22.2 No. 245 Single-Core 600–2,000 V Power Specification — confirmed in the datasheet and quotation for your order.
Application fit
IEEE 1580 Type P & UL 1309 600 V – 2,000 V Single-Core (1/C) Extra-Flexible Propulsion & Winch Feeder Cable (IEEE 1580 Type P / UL 1309) engineered for 600 V / 0.6/1 kV / 2 kV service across -40 to +125 °C (min. bend radius 6 × OD).
Halogen-free SHF1/SHF2, IEEE 1580 Type P or PE/PP submarine outer serving withstands marine salt mist, drilling mud and seabed/deck duty.
Approved for submarine seabed burial, J-tube pull-in, offshore platform cable ladders and shipboard bulkhead penetrations.
Extruded lead-alloy radial water barrier or cross-linked marine elastomer sheath prevents moisture ingress in subsea and wet-deck service.
Compacted copper or extra-flexible Class I/K tinned copper conductors terminate cleanly into offshore switchboards, transformers and thrus
Submarine and armoured offshore power cable is not designed for high-cycle automation drag chains.
Use Drag-Chain Servo CableConstruction
Shown: IEEE 1580 Type P 1/C (IEEE Std 1580 Type P & UL 1309 / CSA C22.2 No. 245 Single-Core 600–2,000 V Power Specification) featuring extra-flexible tinned copper (18 awg-1111 mcm), 125°c thermoset epr/ xlpo insulation and oil & mud-resistant cspe / cpe outer sheath (3-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Extra-Flexible Tinned Copper (18 AWG-111 | Finely stranded annealed tinned copper conductor for high-current feeders |
| 2 | 125°C Thermoset EPR/ XLPO Insulation | High-temperature flame-retardant dielectric (600 V to 2,000 V) |
| 3 | Oil & Mud-Resistant CSPE / CPE Outer She | Thermoset elastomer jacket resistant to drilling mud, oil and UV |
Built to IEEE Std 1580 Type P & UL 1309 / CSA C22.2 No. 245 Single-Core 600–2,000 V Power Specification with extra-flexible tinned copper (18 awg-1111 mcm) and oil & mud-resistant cspe / cpe outer sheath
Available in custom continuous subsea winch, tow or seabed lengths with water-blocked terminations
Supplied with EN 10204 3.1 routine dielectric, optical OTDR / DC resistance & tensile test report
Technical data
Sizes
Manufactured to IEEE Std 1580 Type P & UL 1309 / CSA C22.2 No. 245 Single-Core 600–2,000 V Power Specification for subsea, oceanographic, ROV, seismic and offshore applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Breaking / tensile kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| IEEE 1580 Type P 1/C Construction Schedule (−40…+125 °C) | |||||||
| IEEE 1580 Type P 1 3×16+1G16 mm² | 3 × 16 + 1G16 mm² (or 1C×50 mm²) | IEC 60228 Class 2/5 Cu/SnCu | 22.4 | 920 | 18.5 | 135 | |
| IEEE 1580 Type P 1 3×35+1G16 mm² | 3 × 35 + 1G16 mm² (or 1C×150 mm²) | IEC 60228 Class 2/5 Cu/SnCu | 28.8 | 1,690 | 32.0 | 175 | |
| IEEE 1580 Type P 1 3×95+1G50 mm² | 3 × 95 + 1G50 mm² (or 1C×300 mm²) | IEC 60228 Class 2/5 Cu/SnCu | 41.2 | 3,680 | 58.0 | 250 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 3 × 16 + 1G16 mm² (or 1C×50 mm²) | 1.15 | 600 V / 0.6/1 kV / 2 kV (98 A) | −40…+125 °C |
| 3 × 35 + 1G16 mm² (or 1C×150 mm²) | 0.52 | 600 V / 0.6/1 kV / 2 kV (158 A) | −40…+125 °C |
| 3 × 95 + 1G50 mm² (or 1C×300 mm²) | 0.19 | 600 V / 0.6/1 kV / 2 kV (285 A) | −40…+125 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, optical OTDR continuity & dimensional verification (IEEE Std 1580 Type P & UL 1309 / CSA C22.2 No. 245 Single-Core 600–2,000 V Power Specification) | DC resistance at 20 °C / optical attenuation and outer diameter within IEEE Std 1580 Type P & UL 1309 / CSA C22.2 No. 245 Single-Core 600–2,000 V Power Specification tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (IEEE Std 1580 Type P & UL 1309 / CSA C22.2 No. 245 Single-Core 600–2,000 V Power Specification) | Zero dielectric breakdown and verified insulation resistance for 600 V / 0.6/1 kV / 2 kV rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, tensile breaking load & water-blocking qualification (IEEE Std 1580 Type P & UL 1309 / CSA C22.2 No. 245 Single-Core 600–2,000 V Power Specification) | Verified subsea pressure integrity, torque-balanced tensile performance and thermal stability across −40…+125 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.