Contact
submarine & offshore power composite cableIEEE 1580 Type P / UL 1309600 V / 0.6/1 kV / 2 kV (-40 to +125Oil & Mud-Resistant CSPE / CPE Outer

IEEE 1580 Type P & UL 1309 600 V – 2,000 V Single-Core (1/C) Extra-Flexible Propulsion & Winch Feeder CableIEEE 1580 Type P / UL 1309 — 600 V / 0.6/1 kV / 2 kV — -40 to +125 °C Subsea & Offshore Cable

IEEE 1580 Type P & UL 1309 600 V – 2,000 V Single-Core (1/C) Extra-Flexible Propulsion & Winch Feeder Cable (IEEE 1580 Type P / UL 1309) engineered for 600 V / 0.6/1 kV / 2 kV service across -40 to +125 °C (min. bend radius 6 × OD).

Water-resistant
Flame-retardant
Oil-resistant
Approved
Order designation
IEEE 1580 Type P 1 3×16+1G16 mm²
Outer Ø ≈
22.4 mm
Net weight ≈
920 kg/km
Tensile rating ≈
18.5 kN
Core / stranding
IEC 60228 Class 2/5 Cu/SnCu
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
600 V / 0.6/1 kV
Tested per IEEE 1580 Type P / UL 1309
Operating temp.
−40…+125 °C
Continuous subsea & offshore service
Min. bend radius
6 × OD
Winch sheave, chute & seabed routing
Core / conductor
Extra-Flexible T
Finely stranded annealed tinned copper c
Outer protection
Oil & Mud-Resist
Thermoset elastomer jacket resistant to
Standard
IEEE 1580 Type P
IEEE Std 1580 Type P & UL 1309 / CSA C22

Typical values for this cable type, based on IEEE Std 1580 Type P & UL 1309 / CSA C22.2 No. 245 Single-Core 600–2,000 V Power Specification — confirmed in the datasheet and quotation for your order.

Application fit

Is IEEE 1580 Type P 1/C right for your machine?

IEEE 1580 Type P & UL 1309 600 V – 2,000 V Single-Core (1/C) Extra-Flexible Propulsion & Winch Feeder Cable (IEEE 1580 Type P / UL 1309) engineered for 600 V / 0.6/1 kV / 2 kV service across -40 to +125 °C (min. bend radius 6 × OD).

Offshore platform & shipboard deck trays

Suitable

Halogen-free SHF1/SHF2, IEEE 1580 Type P or PE/PP submarine outer serving withstands marine salt mist, drilling mud and seabed/deck duty.

Fixed installation

Suitable

Approved for submarine seabed burial, J-tube pull-in, offshore platform cable ladders and shipboard bulkhead penetrations.

Immersion & wet locations

Suitable

Extruded lead-alloy radial water barrier or cross-linked marine elastomer sheath prevents moisture ingress in subsea and wet-deck service.

Motor stator, traction & converter leads

Suitable

Compacted copper or extra-flexible Class I/K tinned copper conductors terminate cleanly into offshore switchboards, transformers and thrus

Energy chain / drag chain

Not suitable

Submarine and armoured offshore power cable is not designed for high-cycle automation drag chains.

Use Drag-Chain Servo Cable
Typical machinesMarine & Offshore CableOffshore Wind Inter-Array & Export Submarine LinksSubsea Island & Platform HV/MV Power InterconnectsOffshore Oil & Gas Drilling Rigs & FPSOsCommercial Vessels, Polar Ships & Marine Propulsion

Construction

Layer by layer

Shown: IEEE 1580 Type P 1/C (IEEE Std 1580 Type P & UL 1309 / CSA C22.2 No. 245 Single-Core 600–2,000 V Power Specification) featuring extra-flexible tinned copper (18 awg-1111 mcm), 125°c thermoset epr/ xlpo insulation and oil & mud-resistant cspe / cpe outer sheath (3-layer construction).

123
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Extra-Flexible Tinned Copper (18 AWG-111Finely stranded annealed tinned copper conductor for high-current feeders
2125°C Thermoset EPR/ XLPO InsulationHigh-temperature flame-retardant dielectric (600 V to 2,000 V)
3Oil & Mud-Resistant CSPE / CPE Outer SheThermoset elastomer jacket resistant to drilling mud, oil and UV

IEEE 1580 Type P 1/C — Standard Subsea & Offshore Execution

Built to IEEE Std 1580 Type P & UL 1309 / CSA C22.2 No. 245 Single-Core 600–2,000 V Power Specification with extra-flexible tinned copper (18 awg-1111 mcm) and oil & mud-resistant cspe / cpe outer sheath

IEEE 1580 Type P 1/C — Custom Continuous Winch / Reel Length

Available in custom continuous subsea winch, tow or seabed lengths with water-blocked terminations

IEEE 1580 Type P 1/C — Hydrostatic, Tensile & Routine Certified

Supplied with EN 10204 3.1 routine dielectric, optical OTDR / DC resistance & tensile test report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on IEEE Std 1580 Type P & UL 1309 / CSA C22.2 No. 245 Single-Core 600–2,000 V Power Specification. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
600 V / 0.6/1 kV / 2 kV (IEEE Std 1580 Type P & UL 1309 / CSA C22.2 No. 245 Single-Core 600–2,000 V Power Specification)
Core / conductor construction
Extra-Flexible Tinned Copper (18 AWG-1111 MCM) — Finely stranded annealed tinned copper conductor for high-current feeders
Primary dielectric / buffering
125°C Thermoset EPR/ XLPO Insulation — High-temperature flame-retardant dielectric (600 V to 2,000 V)

Thermal

Continuous operating temperature
−40…+125 °C (subsea & offshore duty)
Hydrostatic & thermal stability
Verified thermal and hydrostatic stability per IEEE Std 1580 Type P & UL 1309 / CSA C22.2 No. 245 Single-Core 600–2,000 V Power Specification
Storage & transport temperature
−40…+80 °C on export wooden/steel winch reel

Mechanical

Outer protection / armouring
Oil & Mud-Resistant CSPE / CPE Outer Sheath — Thermoset elastomer jacket resistant to drilling mud, oil and UV
Minimum bending radius
6 × OD
Armour, strength member & mechanical duty
125°C Thermoset EPR/ XLPO Insulation — High-temperature flame-retardant dielectric (600 V to 2,000 V)

Resistance

Seawater, hydrostatic & hydrolysis resistance
Engineered for continuous seawater immersion, pressure cycling and hydrolysis resistance per IEEE Std 1580 Type P & UL 1309 / CSA C22.2 No. 245 Single-Core 600–2,000 V Power Specification
Oil, drilling mud & abrasion resistance
Resistant to marine hydraulic oils, salt mist, winch sheave wear and seabed abrasion per IEEE Std 1580 Type P & UL 1309 / CSA C22.2 No. 245 Single-Core 600–2,000 V Power Specification
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
IEEE Std 1580 Type P & UL 1309 / CSA C22.2 No. 245 Single-Core 600–2,000 V Power Specification
Environmental & test standards
IEC 60228 / IEC 60794 / ITU-T G.972 / IEEE 1580 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
IEEE 1580 Type P 1/C
Sheath colour & metre marking
Continuous metre-marked black outer finish (Oil & Mud-Resist)
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard IEEE 1580 Type P 1/C subsea & offshore configurations

Manufactured to IEEE Std 1580 Type P & UL 1309 / CSA C22.2 No. 245 Single-Core 600–2,000 V Power Specification for subsea, oceanographic, ROV, seismic and offshore applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Breaking / tensile
kN ≈
Min. bend R
mm
Enquiry
IEEE 1580 Type P 1/C Construction Schedule (−40…+125 °C)
IEEE 1580 Type P 1 3×16+1G16 mm²3 × 16 + 1G16 mm² (or 1C×50 mm²)IEC 60228 Class 2/5 Cu/SnCu22.492018.5135
IEEE 1580 Type P 1 3×35+1G16 mm²3 × 35 + 1G16 mm² (or 1C×150 mm²)IEC 60228 Class 2/5 Cu/SnCu28.81,69032.0175
IEEE 1580 Type P 1 3×95+1G50 mm²3 × 95 + 1G50 mm² (or 1C×300 mm²)IEC 60228 Class 2/5 Cu/SnCu41.23,68058.0250
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour breaking loads and continuous winch/seabed lengths available per IEEE Std 1580 Type P & UL 1309 / CSA C22.2 No. 245 Single-Core 600–2,000 V Power Specification.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, optical OTDR continuity & dimensional verification (IEEE Std 1580 Type P & UL 1309 / CSA C22.2 No. 245 Single-Core 600–2,000 V Power Specification)DC resistance at 20 °C / optical attenuation and outer diameter within IEEE Std 1580 Type P & UL 1309 / CSA C22.2 No. 245 Single-Core 600–2,000 V Power Specification tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (IEEE Std 1580 Type P & UL 1309 / CSA C22.2 No. 245 Single-Core 600–2,000 V Power Specification)Zero dielectric breakdown and verified insulation resistance for 600 V / 0.6/1 kV / 2 kV ratingEvery manufactured drum length
Sample tests
Hydrostatic pressure, tensile breaking load & water-blocking qualification (IEEE Std 1580 Type P & UL 1309 / CSA C22.2 No. 245 Single-Core 600–2,000 V Power Specification)Verified subsea pressure integrity, torque-balanced tensile performance and thermal stability across −40…+125 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

IEEE 1580 Type P / UL 1309 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX IEEE 1580 Type P 1/C IEEE 1580 Type P / UL 1309 600 V / 0.6/1 kV / 2 kV CE
Delivery form
Heavy-duty export fumigated wooden drums, steel oceanographic winch reels or submarine turntables
Standard lengths
500 m, 1,000 m, 3,000 m, 6,000 m or custom continuous subsea lengths
MOQ
100 m (standard configurations) · 500 m (custom subsea builds)
Lead time
2–6 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-26
Updated
2026-10-26

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define IEEE 1580 Type P 1/C (IEEE 1580 Type P & UL 1309 600 V – 2,000 V Single-Core (1/C) Extra-Flexible Propulsion & Winch Feeder Cable)?
IEEE 1580 Type P 1/C (IEEE 1580 Type P & UL 1309 600 V – 2,000 V Single-Core (1/C) Extra-Flexible Propulsion & Winch Feeder Cable) is manufactured in accordance with IEEE Std 1580 Type P & UL 1309 / CSA C22.2 No. 245 Single-Core 600–2,000 V Power Specification for 600 V / 0.6/1 kV / 2 kV service over -40 to +125 °C. Its 3-layer construction comprises extra-flexible tinned copper (18 awg-1111 mcm), 125°c thermoset epr/ xlpo insulation and oil & mud-resistant cspe / cpe outer sheath.
What is the minimum bending radius and operating temperature range for IEEE 1580 Type P 1/C?
The minimum bending radius for IEEE 1580 Type P 1/C is 6 × OD across its continuous operating temperature range of -40 to +125 °C, ensuring mechanical, hydrostatic and dielectric reliability in subsea and offshore service.
How are the concentric layers of IEEE 1580 Type P 1/C arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Extra-Flexible Tinned Copper (18 AWG-1111 MCM) — Finely stranded annealed tinned copper conductor for high-current feeders; (02) 125°C Thermoset EPR/ XLPO Insulation — High-temperature flame-retardant dielectric (600 V to 2,000 V); (03) Oil & Mud-Resistant CSPE / CPE Outer Sheath — Thermoset elastomer jacket resistant to drilling mud, oil and UV.
What factory test certificates are supplied with IEEE 1580 Type P 1/C?
Every production drum of IEEE 1580 Type P 1/C undergoes routine conductor resistance/OTDR continuity, high-voltage dielectric and dimensional testing per IEEE Std 1580 Type P & UL 1309 / CSA C22.2 No. 245 Single-Core 600–2,000 V Power Specification, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for IEEE 1580 Type P 1/C

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

IEEE 1580 Type P & UL 1309 600 V – 2,000 V Single-Core (1/C) Extra-Flexible Propulsion & Winch Feeder Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote