Offshore platform & shipboard deck trays
Halogen-free SHF1/SHF2 or mud-resistant thermoset jacket withstands marine salt mist, oil and deck weathering.
Product
RFOU (M) P2–P4 / P19–P22 3.6/6–18/30 kV NEK 606 Mud-Resistant Offshore Medium-Voltage Power Cable (NEK TS 606 / IEC 60092-354) engineered for 3.6/6 kV – 18/30 kV service across -40 to +90 °C (min. bend radius 12 × OD).
Typical values for this cable type, based on NEK TS 606 Code P2–P4 & P19–P22 / IEC 60092-354 SHF2-MUD — confirmed in the datasheet and quotation for your order.
Application fit
RFOU (M) P2–P4 / P19–P22 3.6/6–18/30 kV NEK 606 Mud-Resistant Offshore Medium-Voltage Power Cable (NEK TS 606 / IEC 60092-354) engineered for 3.6/6 kV – 18/30 kV service across -40 to +90 °C (min. bend radius 12 × OD).
Halogen-free SHF1/SHF2 or mud-resistant thermoset jacket withstands marine salt mist, oil and deck weathering.
Approved for bulkheads, cable trays, ladders and hull penetrations on commercial vessels and offshore units.
Metallic braid armour and cross-linked EPR/XLPE/XLPO insulation handle heavy mechanical and thermal duty.
Stranded copper or tinned copper conductors terminate cleanly into marine switchboards, thrusters and transformers.
Armoured shipboard and offshore feeder cable is not designed for high-cycle automation drag chains.
Use Drag-Chain Servo CableConstruction
Shown: RFOU (M) P2-P4 / P19-P22 3.6/6-18/30 KV (NEK TS 606 Code P2–P4 & P19–P22 / IEC 60092-354 SHF2-MUD) featuring compacted tinned copper (3×95 mm²), triple-extruded hepr mv dielectric and red shf2-mud mv outer sheath (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Compacted Tinned Copper (3×95 mm²) | IEC 60228 Class 2 / Class 5 tinned copper conductors |
| 2 | Triple-Extruded HEPR MV Dielectric | Semi-conducting conductor screen + HEPR insulation + insulation screen |
| 3 | Individual Copper Tape Screen | Overlapped annealed copper tape metallic screen on each phase |
| 4 | SHF2 Inner Bedding & TCWB Armour | Extruded SHF2 inner sheath + tinned copper wire braid armour |
| 5 | Red SHF2-MUD MV Outer Sheath | Medium-voltage red mud-resistant thermoset jacket (NEK TS 606) |
Built to NEK TS 606 Code P2–P4 & P19–P22 / IEC 60092-354 SHF2-MUD with compacted tinned copper (3×95 mm²) and red shf2-mud mv outer sheath
Available in custom continuous shipboard/offshore drum lengths or with marine EMC cable glands
Supplied with EN 10204 3.1 routine dielectric, conductor resistance & flame/fire test report
Technical data
Sizes
Manufactured to NEK TS 606 Code P2–P4 & P19–P22 / IEC 60092-354 SHF2-MUD for shipboard, offshore platform, drilling rig and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| RFOU (M) P2-P4 / P19-P22 3.6/6-18/30 KV Construction Schedule (−40…+90 °C) | |||||||
| RFOU 3×50 mm² MV | 3 × 50 mm² | IEC 60228 Class 2/5 Cu/SnCu | 42.5 | 2,980 | 22.5 | 510 | |
| RFOU 3×95 mm² MV | 3 × 95 mm² | IEC 60228 Class 2/5 Cu/SnCu | 51.8 | 4,690 | 42.8 | 620 | |
| RFOU 3×150 mm² MV | 3 × 150 mm² | IEC 60228 Class 2/5 Cu/SnCu | 61.2 | 6,840 | 67.5 | 735 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 3 × 50 mm² | 0.39 | 3.6/6 kV – 18/30 kV (195 A) | −40…+90 °C |
| 3 × 95 mm² | 0.19 | 3.6/6 kV – 18/30 kV (285 A) | −40…+90 °C |
| 3 × 150 mm² | 0.12 | 3.6/6 kV – 18/30 kV (365 A) | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (NEK TS 606 Code P2–P4 & P19–P22 / IEC 60092-354 SHF2-MUD) | DC resistance at 20 °C / optical attenuation and outer diameter within NEK TS 606 Code P2–P4 & P19–P22 / IEC 60092-354 SHF2-MUD tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (NEK TS 606 Code P2–P4 & P19–P22 / IEC 60092-354 SHF2-MUD) | Zero dielectric breakdown and verified insulation resistance for 3.6/6 kV – 18/30 kV rating | Every manufactured drum length |
| Sample tests | ||
| Flame, fire integrity, oil/mud & mechanical qualification (NEK TS 606 Code P2–P4 & P19–P22 / IEC 60092-354 SHF2-MUD) | Verified flame/fire performance, fluid resistance and thermal stability across −40…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.