Mine roadway & tunnel wall hangers
Engineered for underground mining shafts, galleries and tunnel infrastructure per DIN VDE 0271 / IEC 60502-2 / IEC 60332-1-2.
Product
Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per DIN VDE 0271 / IEC 60502-2 / IEC 60332-1-2 across -20 to +70 °C.
Typical values for this cable type, based on DIN VDE 0271 / IEC 60502-2 / IEC 60332-1-2 — confirmed in the datasheet and quotation for your order.
Application fit
Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per DIN VDE 0271 / IEC 60502-2 / IEC 60332-1-2 across -20 to +70 °C.
Engineered for underground mining shafts, galleries and tunnel infrastructure per DIN VDE 0271 / IEC 60502-2 / IEC 60332-1-2.
Suitable for vertical shaft cleats, gallery messenger hooks and tray routing within 12 × OD.
Supports inclined roadway and vertical mine shaft suspension within rated kN load across -20 to +70 °C.
Not optimized for high-speed overhead crane C-track festoon loops; select a dedicated festoon cable.
NGFLGÖU Flat Rubber Festoon CableConstruction
Shown: NYFGY (DIN VDE 0271 / IEC 60502-2 / IEC 60332-1-2) featuring phase conductors (3×95 mm²), mv pvc core insulation (yi4) and outer sheath (red fr-pvc) (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Phase Conductors (3×95 mm²) | DIN EN 60228 Class 2 stranded annealed plain copper conductors |
| 2 | MV PVC Core Insulation (YI4) | High-dielectric YI4 compound PVC insulation rated for 3.6/6 kV |
| 3 | Tightness Inner Sheath | Extruded grey PVC filler and sealing inner bedding sheath |
| 4 | Flat Steel Wire & Counter-Tape (FG) | Galvanized steel wire armour (F) + counter-helix steel binder tape (G) |
| 5 | Outer Sheath (Red FR-PVC) | Flame-retardant red PVC outer jacket per DIN VDE 0271 / IEC 60332-1-2 |
Built to DIN VDE 0271 / IEC 60502-2 / IEC 60332-1-2 with phase conductors (3×95 mm²) and outer sheath (red fr-pvc)
Available in custom shaft/roadway drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & flame test report
Technical data
Sizes
Manufactured to DIN VDE 0271 / IEC 60502-2 / IEC 60332-1-2 for underground mining, open-cast excavation, shaft and heavy industrial systems.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| NYFGY Construction Schedule (-20 to +70 °C) | |||||||
| NYFGY 3×50 rm 3.6/6 kV | 3 × 50 mm² + FG Armour | Class 2 plain Cu | 39.5 | 2,840 | 22.5 | 475 | |
| NYFGY 3×95 rm 3.6/6 kV | 3 × 95 mm² + FG Armour | Class 2 plain Cu | 47.8 | 4,620 | 42.8 | 575 | |
| NYFGY 3×150 rm 3.6/6 kV | 3 × 150 mm² + FG Armour | Class 2 plain Cu | 55.4 | 6,590 | 67.5 | 665 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 3 × 50 mm² + FG Armour | 0.39 | 3.6/6 kV (175 A) | -20 to +70 °C |
| 3 × 95 mm² + FG Armour | 0.19 | 3.6/6 kV (255 A) | -20 to +70 °C |
| 3 × 150 mm² + FG Armour | 0.12 | 3.6/6 kV (330 A) | -20 to +70 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (DIN VDE 0271 / IEC 60502-2 / IEC 60332-1-2) | DC resistance at 20 °C / optical attenuation and outer diameter within DIN VDE 0271 / IEC 60502-2 / IEC 60332-1-2 tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (DIN VDE 0271 / IEC 60502-2 / IEC 60332-1-2) | Zero dielectric breakdown and verified insulation resistance over full production length | Every manufactured drum length |
| Sample tests | ||
| Flame propagation, mechanical crush & thermal ageing qualification (DIN VDE 0271 / IEC 60502-2 / IEC 60332-1-2) | Verified flame retardancy, mechanical integrity and thermal endurance across -20 to +70 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.