Contact
PN-G-90006 water-blocked steel-tape armoured mining MV cablePN-G-90006 / EMAG6/10 kV XLPE + Water-BlockedDouble Steel Tape (FtZn)

YUHKGXSFtZnyn 6/10 kV Water-Blocked Steel-Tape Mining CableYUHKGXSFtZnyn 6/10 kV longitudinally water-blocked (U) and double steel-tape armoured (FtZn) medium-voltage mining roadway feeder cable per PN-G-90006 for ≤45° inclines, with a central bare earth core, 3 screened XLPE phases and red FR-PVC sheath.

Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per PN-G-90006 / WT-TK-38 / IEC 60332-3-24 across -30 to +90 °C.

Water-resistant
EMC screen
Flame-retardant
Approved
Order designation
YUHKGXSFtZnyn 3×70 + 16 mm² 6/10 kV
Outer Ø ≈
51.0 mm
Net weight ≈
4,640 kg/km
Tensile rating ≈
31.5 kN
Core / stranding
Class 2 compacted Cu + FtZn
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
6/10 kV
6/10 kV & 3.6/6 kV wet roadway (≤45°)
Operating temp.
-30 to +90 °C
Continuous mining & industrial duty
Min. bend radius
15 × OD
Fixed installation / dynamic routing
Core / conductor
3×35–240 + E Cu
Class 2 Cu + central bare earth core
Outer protection
U + FtZn + yn
Swelling tape + steel tape + red FR-PVC
Standard
PN-G-90006
PN-G-90006 / WT-TK-38 / IEC 60332-3-24

Typical values for this cable type, based on PN-G-90006 / WT-TK-38 / IEC 60332-3-24 — confirmed in the datasheet and quotation for your order.

Application fit

Is YUHKGXSFtZnyn right for your machine?

Engineered for underground mining, open-cast excavation, shaft infrastructure and heavy industrial service per PN-G-90006 / WT-TK-38 / IEC 60332-3-24 across -30 to +90 °C.

Mine roadway & tunnel wall hangers

Suitable

Engineered for underground mining shafts, galleries and tunnel infrastructure per PN-G-90006 / WT-TK-38 / IEC 60332-3-24.

Fixed installation

Suitable

Suitable for vertical shaft cleats, gallery messenger hooks and tray routing within 15 × OD.

Free-hanging vertical run

Suitable

Supports inclined roadway and vertical mine shaft suspension within rated kN load across -30 to +90 °C.

Typical machinesMining & TunnellingUnderground Coal & Hard-Rock MiningOpen-Cast Excavators, Draglines & ShovelsVertical Mine Shafts, Hoists & BoreholesTunneling, Mineral Processing & Slurry Plants

Construction

Layer by layer

Shown: YUHKGXSFtZnyn (PN-G-90006 / WT-TK-38 / IEC 60332-3-24) featuring central bare earth core (16 mm²), phase cores (3×70 mm² xlpe + h) and mining flame-retardant sheath (yn) (5-layer construction).

12345
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Central Bare Earth Core (16 mm²)Class 2 compacted circular bare copper earth conductor at cable center
2Phase Cores (3×70 mm² XLPE + H)Class 2 bare copper + XLPE (XS) + semicon + individual copper tape screen
3PVC Inner Sheath & Swelling Tape (U)Core filling + black PVC inner sheath (Y) + longitudinal water-blocking tapes
4Double Steel Tape Armour (FtZn)Two helically lapped galvanized flat steel tapes for radial crush protection
5Mining Flame-Retardant Sheath (yn)Red high-oxygen-index (LOI ≥ 29%) Cat. C flame-retardant PVC outer jacket

YUHKGXSFtZnyn — Standard Mining Execution

Built to PN-G-90006 / WT-TK-38 / IEC 60332-3-24 with central bare earth core (16 mm²) and mining flame-retardant sheath (yn)

YUHKGXSFtZnyn — Custom Drum Length & Gland Kit

Available in custom shaft/roadway drum lengths or pre-terminated assemblies

YUHKGXSFtZnyn — Routine & Flame Test Certified

Supplied with EN 10204 3.1 routine dielectric, resistance & flame test report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on PN-G-90006 / WT-TK-38 / IEC 60332-3-24. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
6/10 kV (PN-G-90006 / WT-TK-38 / IEC 60332-3-24)
Core / conductor construction
Central Bare Earth Core (16 mm²) — Class 2 compacted circular bare copper earth conductor at cable center
Primary dielectric / buffering
Phase Cores (3×70 mm² XLPE + H) — Class 2 bare copper + XLPE (XS) + semicon + individual copper tape screen

Thermal

Continuous operating temperature
-30 to +90 °C (mining & industrial service)
Short-circuit / peak thermal rating
Verified thermal stability per PN-G-90006 / WT-TK-38 / IEC 60332-3-24
Storage & transport temperature
−40…+80 °C on export wooden/steel drum

Mechanical

Outer protection / armouring
Mining Flame-Retardant Sheath (yn) — Red high-oxygen-index (LOI ≥ 29%) Cat. C flame-retardant PVC outer jacket
Minimum bending radius
15 × OD
Crush, impact & abrasion duty
Heavy-duty mining rock-cut, impact and tensile protection per PN-G-90006 / WT-TK-38 / IEC 60332-3-24

Resistance

Flame retardancy & mine fire safety
Self-extinguishing / flame-retardant mining jacket per PN-G-90006 / WT-TK-38 / IEC 60332-3-24
Mine water, oil & chemical resistance
Resistant to acidic mine water, hydraulic oils and abrasion per PN-G-90006 / WT-TK-38 / IEC 60332-3-24
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
PN-G-90006 / WT-TK-38 / IEC 60332-3-24
Flame & environmental test standards
IEC 60332 / MSHA / EN 60794 / IEC 60228
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
YUHKGXSFtZnyn
Sheath colour & metre marking
Continuous metre-marked red mining outer sheath
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard YUHKGXSFtZnyn mining & industrial configurations

Manufactured to PN-G-90006 / WT-TK-38 / IEC 60332-3-24 for underground mining, open-cast excavation, shaft and heavy industrial systems.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Tensile rating
kN ≈
Min. bend R
mm
Enquiry
YUHKGXSFtZnyn Construction Schedule (-30 to +90 °C)
YUHKGXSFtZnyn 3×50 + 16 mm² 6/10 kV3 × 50 mm² + 16 mm² Central EarthClass 2 compacted Cu + FtZn46.83,69022.5700
YUHKGXSFtZnyn 3×70 + 16 mm² 6/10 kV3 × 70 mm² + 16 mm² Central EarthClass 2 compacted Cu + FtZn51.04,64031.5765
YUHKGXSFtZnyn 3×120 + 25 mm² 6/10 kV3 × 120 mm² + 25 mm² Central EarthClass 2 compacted Cu + FtZn59.86,89054.0895
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour grades and factory drum lengths available per PN-G-90006 / WT-TK-38 / IEC 60332-3-24.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, continuity & dimensional verification (PN-G-90006 / WT-TK-38 / IEC 60332-3-24)DC resistance at 20 °C / optical attenuation and outer diameter within PN-G-90006 / WT-TK-38 / IEC 60332-3-24 tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (PN-G-90006 / WT-TK-38 / IEC 60332-3-24)Zero dielectric breakdown and verified insulation resistance over full production lengthEvery manufactured drum length
Sample tests
Flame propagation, mechanical crush & thermal ageing qualification (PN-G-90006 / WT-TK-38 / IEC 60332-3-24)Verified flame retardancy, mechanical integrity and thermal endurance across -30 to +90 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

PN-G-90006 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX YUHKGXSFtZnyn PN-G-90006 6/10 kV CE
Delivery form
Heavy-duty export fumigated wooden drums or steel mine reels
Standard lengths
500 m, 1,000 m or custom continuous shaft/reeling lengths
MOQ
100 m (standard configurations) · 500 m (custom builds)
Lead time
2–5 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-24
Updated
2026-10-24

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define YUHKGXSFtZnyn (YUHKGXSFtZnyn 6/10 kV Water-Blocked Steel-Tape Mining Cable)?
YUHKGXSFtZnyn (YUHKGXSFtZnyn 6/10 kV Water-Blocked Steel-Tape Mining Cable) is manufactured in accordance with PN-G-90006 / WT-TK-38 / IEC 60332-3-24 for 6/10 kV duty over -30 to +90 °C. Its 5-layer construction comprises Central Bare Earth Core (16 mm²), Phase Cores (3×70 mm² XLPE + H) and Mining Flame-Retardant Sheath (yn).
What is the minimum bending radius and operating temperature range for YUHKGXSFtZnyn?
The minimum bending radius for YUHKGXSFtZnyn is 15 × OD across its continuous operating temperature range of -30 to +90 °C, ensuring mechanical and dielectric reliability in mining and heavy industrial service.
How are the concentric layers of YUHKGXSFtZnyn arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Central Bare Earth Core (16 mm²) (Class 2 compacted circular bare copper earth conductor at cable center); (02) Phase Cores (3×70 mm² XLPE + H) (Class 2 bare copper + XLPE (XS) + semicon + individual copper tape screen); (03) Filling, PVC Inner Sheath & Swelling Tape (U) (Core filling + black PVC inner sheath (Y) + longitudinal water-blocking tapes); (04) Double Steel Tape Armour (FtZn) (Two helically lapped galvanized flat steel tapes for radial crush protection); (05) Mining Flame-Retardant Sheath (yn) (Red high-oxygen-index (LOI ≥ 29%) Cat. C flame-retardant PVC outer jacket).
What factory test certificates are supplied with YUHKGXSFtZnyn?
Every production drum of YUHKGXSFtZnyn undergoes routine conductor resistance/continuity, high-voltage dielectric and dimensional testing per PN-G-90006 / WT-TK-38 / IEC 60332-3-24, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for YUHKGXSFtZnyn

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

YUHKGXSFtZnyn 6/10 kV Water-Blocked Steel-Tape Mining Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote