Magnet & winding wires

Enamelled round copper, aluminum and CCA magnet wires, self-bonding coil wires, Kraft and aramid paper-wrapped transformer conductors, polyimide-FEP flat wires and hollow water-cooled profiles built to IEC 60317 and NEMA MW.

How does the cable move?

Pick one or more duties — the list below updates.

11 magnet and winding wires

Voltage
Standard
Sheath
Features

Enamelled & self-bonding wires

Class 155 polyurethane, self-bonding PB155, multifilar, CCA and Class 200 PEI/PAI aluminum magnet wires.

5 cables
CCA ENAMELLED WIRE — cable cross-section
Class 155 Polyurethane Enamelled Copper-Clad Aluminum Winding WireClass 155 Polyurethane Enamelled Copper-Clad Aluminum Winding Wire
1–1 kV
Motor & traction leads, control cabinet
IECOther
1–1 kV, IEC, Other sheathMotor & traction leads, control cabinet
MAGNET WIRE P155 — cable cross-section
MAGNET WIRE P155IEC 60317-20 Class 155 Solderable Polyurethane Enamelled Round
1–1 kV
Motor & traction leads, control cabinet
IECOther
1–1 kV, IEC, Other sheathMotor & traction leads, control cabinet
MW 131-C / IEC 60317-35 PB155 — cable cross-section
MW 131-C / IEC 60317-35 PB155Class 155 Solderable Polyurethane Self-Bonding Enamelled Copper
1–1 kV
Motor & traction leads, control cabinet
IECOther
1–1 kV, IEC, Other sheathMotor & traction leads, control cabinet
MW 35-A / IEC 60317-25 EAIW-AL 200 — cable cross-section
MW 35-A / IEC 60317-25 EAIW-AL 200Class 200 Polyesterimide + PAI Overcoat Enamelled Aluminum Magnet
1–1 kV
Motor & traction leads, VFD motor feeder
IECOther
1–1 kV, IEC, Other sheathMotor & traction leads, VFD motor feeder
MULTIFILAR BONDED MAGNET WIRE — cable cross-section
Parallel Multifilar Self-Bonding Polyurethane Enamelled CopperParallel Multifilar Self-Bonding Polyurethane Enamelled Copper
1–1 kV
Motor & traction leads, control cabinet
IECOther
1–1 kV, IEC, Other sheathMotor & traction leads, control cabinet

Paper, glass & polyimide wires

Aramid and Kraft paper transformer wires, crepe-paper lead ropes, glass-fiber and Class 240 polyimide-FEP flat wires.

5 cables
POLYESTER-GLASS ENAMEL WIRE — cable cross-section
IEC 60317-48 Class 200 Enamelled + Dacron/Glass-Fiber Yarn CoveredIEC 60317-48 Class 200 Enamelled + Dacron/Glass-Fiber Yarn Covered
1–3.6 kV
Motor & traction leads, furnace & kiln
IECGlass braid
1–3.6 kV, IEC, Glass braid sheathMotor & traction leads, furnace & kiln
POLYIMIDE-FEP FLAT WIRE — cable cross-section
Class 240 Polyimide-FEP Film-Tape Wrapped Rectangular CopperClass 240 Polyimide-FEP Film-Tape Wrapped Rectangular Copper
1–6 kV
Motor & traction leads, submerged
IECFluoropolymer
1–6 kV, IEC, Fluoropolymer sheathMotor & traction leads, submerged
CTC-AR Aramid-Paper Covered Wire — cable cross-section
Aramid Paper-Wrapped Round Copper Winding WireAramid Paper-Wrapped Round Copper Winding Wire
1–35 kV
Motor & traction leads, fixed
IECOther
1–35 kV, IEC, Other sheathMotor & traction leads, fixed
PIC-PK Kraft-Paper Flat Copper Wire — cable cross-section
Thermally Upgraded Kraft Paper-Insulated Rectangular Copper WindingThermally Upgraded Kraft Paper-Insulated Rectangular Copper Winding
1–110 kV
Motor & traction leads, fixed
IECOther
1–110 kV, IEC, Other sheathMotor & traction leads, fixed
CREPE-PAPER COPPER ROPE — cable cross-section
CREPE-PAPER COPPER ROPECrepe-Paper Insulated Flexible Stranded Copper Transformer Lead Rope
10–220 kV
Motor & traction leads, fixed
IECOther
10–220 kV, IEC, Other sheathMotor & traction leads, fixed

Hollow water-cooled conductors

Seamless Cu-OFE oxygen-free hollow copper profiles for direct water-cooled electromagnets and induction coils.

1 cable
OFC-HC Hollow Water-Cooled Conductor — cable cross-section
OFC-HC Hollow Water-Cooled ConductorOxygen-Free Copper Hollow Water-Cooled Magnet Conductor Profile
1–10 kV
Furnace & kiln, fixed
EN / HDOther
1–10 kV, EN / HD, Other sheathFurnace & kiln, fixed

Choosing magnet and winding wires

Four things decide most selections. Our engineers check the rest against your application.

Application and movement duty

  • Define whether the cable runs in a fixed tray, energy chain, festoon loop, reel or trailing route.
  • Match travel speed, bend radius and tensile load to the mechanical construction.
  • Select a support element or armour when the cable carries suspended weight or external crush loads.

Voltage class and core layout

  • Match the rated voltage U0/U to the supply system and earthing arrangement.
  • Specify phase cross-sections, protective earth, pilot cores or control pairs required by the machine.
  • Include copper braid, tape or semiconductive screens where EMC or electric-field control is needed.

Operating environment and sheath

  • Choose rubber, PUR, LSZH, PVC, fluoropolymer or silicone sheaths for the thermal and chemical exposure.
  • Verify oil, UV, water immersion, cold-flex or circuit-integrity ratings against site conditions.
  • Check outer diameter and gland compatibility at both terminations.

Standard and documentation

  • Confirm the governing standard family required by the project specification.
  • Verify conductor class, colour code or core numbering for the destination region.
  • Include operating duty and cable length in your enquiry so we can confirm the build.

Questions buyers ask

Not covered here? Send your drawing and an engineer replies within 2 business hours.

Ask on WhatsApp
How do I select the right cable assembly from this range?

Start by filtering the list by movement duty, voltage band and sheath material. Compare how each cable assembly is constructed—conductor flexibility, insulation compound, screening and outer jacket—against your machine's bending radius, travel speed and ambient temperature. Open the product page or datasheet to check core counts, cross-sections and outer diameters before sending your enquiry.

When should cable assemblies include metallic screening or armour?

Specify a copper braid or foil screen when cable assemblies run near variable-frequency drives, carry analogue or fieldbus signals, or require medium-voltage electric-field control. Choose steel wire braid or armour when the installation faces rock fall, crushing loads or high pulling tension in roadways, decks or subsea routes.

Which outer sheath compound suits harsh industrial environments?

Heavy-duty rubber (PCP or CPE) provides balanced mechanical toughness, weather resistance and thermal stability. Polyurethane (PUR) resists cuts, abrasion and mineral oils on fast-moving chains, reels and trolleys. Halogen-free LSZH compounds reduce smoke and acid gas in tunnels, ships and enclosed buildings, while fluoropolymers and silicone handle extreme heat.

What details should I include in an RFQ for cable assemblies?

Include the model designation or governing standard, rated voltage, number of cores and conductor cross-sections, along with the installation method, minimum bend radius, ambient temperature range and required delivery lengths. If you are replacing an existing cable on a machine, share the sheath marking so we can match the specification.

Engineering reference

Background on how magnet and winding wires are built, rated and specified.

Read the full reference

Cable assemblies cover industrial constructions engineered for reliable electrical transmission under defined mechanical, thermal and environmental stresses. Selecting the right build requires matching conductor stranding, insulation system, screening and outer sheath compound to the actual installation route rather than relying on nominal cross-section alone.

Across the TEBAOFLEX cable assemblies portfolio, models are grouped into functional families so engineers can filter by duty, voltage band, standard family and jacket compound. Each construction addresses a specific balance of flexibility, dielectric strength, electromagnetic compatibility and resistance to oil, water, UV radiation or flame propagation.

Before finalizing a specification, verify the governing national or international standard, operating voltage U0/U, ambient temperature range and minimum bending radius in fixed or moving duty. Where cables interface with connectors, glands or motor terminal boxes, check nominal outer diameter and screen termination geometry early.

When submitting an RFQ for cable assemblies, specify the model designation, core count and cross-sections, system voltage, installation method, environmental exposure and required drum or assembly lengths so our engineering team can confirm the exact construction and datasheet.

Compare cables

Voltage
Standard
Sheath
Features
Typical use

Highlighted rows differ between the selected cables.

Filters

Duty

Voltage

Standard

Sheath

Features