Immersion & wet locations
AD8 water-resistant XLPO insulation and blue BWS-8 sheath withstand permanent fresh or brackish water immersion.
Product
Single-core 1.5 kV DC (max. 1.8 kV DC) floating photovoltaic cable to 2 PfG 2750, EN 50618 and IEC 62930 with Class 5 tinned copper and blue AD8 water-resistant XLPO sheath.
Typical values for this cable type, based on TÜV 2 PfG 2750 / EN 50618 / IEC 62930 — confirmed in the datasheet and quotation for your order.
Application fit
Single-core 1.5 kV DC (max. 1.8 kV DC) floating photovoltaic cable to 2 PfG 2750, EN 50618 and IEC 62930 with Class 5 tinned copper and blue AD8 water-resistant XLPO sheath.
AD8 water-resistant XLPO insulation and blue BWS-8 sheath withstand permanent fresh or brackish water immersion.
Rated for 25+ years outdoor UV, ozone and weather exposure on floating pontoons and open PV racks.
Suitable for short pontoon-to-pontoon catenary spans when mechanically supported within 5 × OD bend limits.
Single-core solar cable is not built for mobile dragging across abrasive ground or mining floors.
Use H07RN-F Rubber CableNot rated for continuous high-cycle industrial energy-chain flexing.
Use Drag-Chain CableAD8 water-resistant 1.5/1.5 kV DC build withstands continuous humidity, wave motion, and UV exposure across floating solar pontoons.
Construction
Shown: PV 1500-WR 1×6 mm² — Class 5 tinned copper conductor, white AD8 water-resistant XLPO insulation and blue BWS-8 XLPO outer sheath.
| # | Layer | Material & reference |
|---|---|---|
| 1 | Conductor | IEC 60228 Class 5 fine-stranded tinned electrolytic copperIEC 60228 Class 5 |
| 2 | Water-resistant insulation | White AD8 water-resistant cross-linked polyolefin (XLPO)2 PfG 2750 / EN 50618 |
| 3 | Outer sheath | Blue BWS-8 halogen-free cross-linked polyolefin (XLPO) sheath2 PfG 2750 / IEC 62930 |
Water-resistant blue XLPO jacket for floating solar identification
Black or red AD8 jacket colours available on project request
Technical data
Sizes
Typical dimensions for AD8 water-resistant 1.5 kV DC floating PV cables. Higher combiner cross-sections on request.
| Order designation | Cores × mm² | AWG ≈ | Outer Ø ≈ mm | Max. DCR 20 °C Ω/km | Weight ≈ kg/km | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| 1.5 kV DC single-core floating PV | |||||||
| PV 1500-WR 1×2.5 | 1 × 2.5 mm² | 14 AWG | 5.3 | 8.21 | 46 | 21 | |
| PV 1500-WR 1×4 | 1 × 4 mm² | 12 AWG | 5.8 | 5.09 | 63 | 23 | |
| PV 1500-WR 1×6 | 1 × 6 mm² | 10 AWG | 6.5 | 3.39 | 85 | 26 | |
| PV 1500-WR 1×10 | 1 × 10 mm² | 8 AWG | 7.7 | 1.95 | 134 | 31 | |
| PV 1500-WR 1×16 | 1 × 16 mm² | 6 AWG | 9.1 | 1.24 | 205 | 36 | |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Spark test & AC/DC withstand test | 6.5 kV AC or 15 kV DC for 5 min without breakdown | Every length |
| Conductor DC resistance & wall thickness | Within IEC 60228 Class 5 tinned Cu & EN 50618 tolerances | Every length |
| Sample tests | ||
| AD8 long-term energised water immersion & damp-heat | 2 PfG 2750 hydrothermal & 2,000 h damp-heat insulation stability | Type qualification |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.