VFD inverter to AC motor screened feeder
Large-AWG (8 AWG–500 kcmil) symmetrical 3+3 design and 5-mil Cu tape eliminate bearing currents on > 100 HP drives.
Product
Heavy-gauge 2,000 V UL 1277 Type TC-ER / RHW-2 symmetrical VFD feeder cable (869 series) with annealed bare copper conductors, heavy-wall 90 °C XLPE insulation, three bare copper grounds, 5-mil bare copper tape shield, and oil/UV-resistant PVC jacket.
Typical values for this cable type, based on UL 1277 Type TC-ER · UL 44 RHW-2 · IEEE 1202 / FT4 · NFPA 79 — confirmed in the datasheet and quotation for your order.
Application fit
Heavy-gauge 2,000 V UL 1277 Type TC-ER / RHW-2 symmetrical VFD feeder cable (869 series) with annealed bare copper conductors, heavy-wall 90 °C XLPE insulation, three bare copper grounds, 5-mil bare copper tape shield, and oil/UV-resistant PVC jacket.
Large-AWG (8 AWG–500 kcmil) symmetrical 3+3 design and 5-mil Cu tape eliminate bearing currents on > 100 HP drives.
NFPA 79 and UL Type TC-ER compliance targets heavy extruders, compressors, and high-horsepower MCC feeders.
Heavy-wall 2 kV RHW-2 XLPE resists corona discharge and standing-wave peaks on long feeder runs.
Oil-, UV-, and direct-burial black RAL 9005 PVC jacket passes IEEE 1202 / FT4 tray flame testing.
Large-AWG copper-tape tray cable is for stationary installation, not continuous drag-chain flexing.
Use (N)12YRDC11Y-J/O PURNot engineered for motorised cable drums; choose a rubber reeling cable for mobile spooling.
Use RG / RG-D (N)SHTOEU-JConstruction
Shown: VFD XLPE 2KV TR (869) 3×2/0 AWG + 3×6 AWG — annealed bare copper 2 kV RHW-2 XLPE phases and three symmetrical bare copper grounds inside an uncoated 5-mil helical copper tape shield and black PVC jacket.
| # | Layer | Material & reference |
|---|---|---|
| 1 | Conductor | Uncoated annealed stranded bare copper (ASTM B8 Class B)ASTM B3 / B8 large-AWG bare copper |
| 2 | Phase insulation | 2 kV heavy-wall RHW-2 XLPE (Black consecutively numbered)UL 44 RHW-2 + 3 × bare Cu interstitial grounds |
| 3 | Fillers & separator | Extruded/cabled interstitial fillers & separator tapeBalanced circular large-AWG assembly |
| 4 | 5-mil copper tape shield | Uncoated 5-mil helically overlapped bare copper tape (100%)Low-impedance VFD EMI shield |
| 5 | Outer jacket | Black oil-, UV- & direct-burial thermoplastic PVC jacket (RAL 9005)UL 1277 Type TC-ER / NFPA 79 |
Three black numbered heavy-wall RHW-2 XLPE phases + three symmetrical bare Cu grounds under 5-mil bare Cu tape (8 AWG–500 kcmil).
Technical data
Sizes
| Phase + 3× Ground (AWG) | Outer Ø ≈ mm | Max. R20 Ω/km | Copper index kg/km | Weight ≈ kg/km | Min. bend R 12×D mm |
|---|---|---|---|---|---|
| 3×8 AWG + 3×14 AWG | 20.8 | 2.100 | 352 | 759 | 250 |
| 3×6 AWG + 3×12 AWG | 22.9 | 1.320 | 528 | 1,048 | 275 |
| 3×4 AWG + 3×12 AWG | 26.6 | 0.832 | 756 | 1,469 | 319 |
| 3×2 AWG + 3×10 AWG | 31.0 | 0.523 | 1,164 | 2,168 | 372 |
| 3×1 AWG + 3×8 AWG | 33.0 | 0.415 | 1,497 | 2,682 | 396 |
| 3×1/0 AWG + 3×6 AWG | 35.2 | 0.329 | 1,944 | 3,355 | 422 |
| 3×2/0 AWG + 3×6 AWG | 37.7 | 0.261 | 2,333 | 3,979 | 452 |
| 3×3/0 AWG + 3×4 AWG | 41.2 | 0.207 | 3,044 | 5,077 | 494 |
| 3×4/0 AWG + 3×4 AWG | 44.4 | 0.164 | 3,664 | 6,059 | 533 |
| 3×250 kcmil + 3×4 AWG | 48.5 | 0.139 | 4,212 | 7,028 | 582 |
| 3×350 kcmil + 3×2 AWG | 54.2 | 0.099 | 5,959 | 9,659 | 650 |
| 3×500 kcmil + 3×2 AWG | 61.4 | 0.070 | 8,071 | 12,931 | 737 |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| AC high-voltage dielectric test | Per UL 44 RHW-2 2,000 V rating | Every manufactured reel |
| Conductor DC resistance check | Per ASTM B8 Class B at 20 °C | Every reel length |
| Sample tests | ||
| TC-ER crush, impact & tape overlap | UL 1277 crush/impact & 100% tape lap | Per production lot |
| Vertical tray flame test | IEEE 1202 / FT4 / UL 1685 | Type approval |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.