Building & Fire Safety Cables

Fire-resistant circuit-integrity cables, alarm wiring and low-smoke halogen-free feeders for public buildings and tunnels.

How does the cable move?

Pick one or more duties — the list below updates.

58 building & fire safety cables

Voltage
Standard
Sheath
Features

Fire-resistant & fire alarm cables

Circuit-integrity and fire-alarm cables that keep emergency circuits working in a fire.

18 cables
NHXCH — cable cross-section
NHXCHNHXCH Fire-Resistant Cable with Concentric Conductor
0.6/1 kV
Fixed, control cabinet
IECHalogen-free
0.6/1 kV, IEC, Halogen-free sheathFixed, control cabinet
NHXH — cable cross-section
NHXHNHXH Halogen-Free Fire-Resistant Power Cable
0.6/1 kV
Fixed, control cabinet
DIN VDEHalogen-free
0.6/1 kV, DIN VDE, Halogen-free sheathFixed, control cabinet
A-H(L)HBH — cable cross-section
A-H(L)HBHA-H(L)HBH LSZH Armoured Outdoor Signalling Cable
300/500 V
Fixed, control cabinet
IECHalogen-free
300/500 V, IEC, Halogen-free sheathFixed, control cabinet
A-HHBH — cable cross-section
A-HHBHA-HHBH Halogen-Free Steel-Tape Armoured Signalling Cable
300/500 V
Fixed, control cabinet
IECHalogen-free
300/500 V, IEC, Halogen-free sheathFixed, control cabinet
BS 7917 U FR — cable cross-section
BS 7917 U FRBS 7917 U FR Unarmoured Fire-Resistant Offshore Power Cable
0.6/1 kV
Fixed, offshore & shipboard
BSHalogen-free
0.6/1 kV, BS, Halogen-free sheathFixed, offshore & shipboard
BS 7917 A FR — cable cross-section
BS 7917 A FRBS 7917 A FR Armoured Fire-Resistant Offshore Power Cable
0.6/1 kV
Fixed, offshore & shipboard
BSHalogen-free
0.6/1 kV, BS, Halogen-free sheathFixed, offshore & shipboard
Fire-Resistant FO FE180 — Fire-Resistant FO FE180 Circuit-Integrity Fibre Optic Cable
Fire-Resistant FO FE180Fire-Resistant FO FE180 Circuit-Integrity Fibre Optic Cable
300/500 V
Fixed, control cabinet
IECHalogen-free
300/500 V, IEC, Halogen-free sheathFixed, control cabinet
SS-LD — cable cross-section
SS-LDSS-LD Digital Linear Heat Detection Cable
300/500 V
Fixed, control cabinet
IECHalogen-free
300/500 V, IEC, Halogen-free sheathFixed, control cabinet
SS-LDN — cable cross-section
SS-LDNSS-LDN Nylon-Jacketed Linear Heat Detection Cable
300/500 V
Fixed, control cabinet
IECRubber
300/500 V, IEC, Rubber sheathFixed, control cabinet
SS-LDS — cable cross-section
SS-LDSSS-LDS Stainless-Steel-Protected Linear Heat Detection Cable
300/500 V
Fixed, control cabinet
IECHalogen-free
300/500 V, IEC, Halogen-free sheathFixed, control cabinet
BS 7846 — cable cross-section
BS 7846BS 7846 Armoured Fire-Resistant Power Cable
0.6/1 kV
Fixed, control cabinet
BSHalogen-free
0.6/1 kV, BS, Halogen-free sheathFixed, control cabinet
S07HXCHX-F — cable cross-section
S07HXCHX-FS07HXCHX-F Screened Halogen-Free Cross-Linked Elastomer Flexible
300/500 V
Fixed, control cabinet
IECHalogen-free
300/500 V, IEC, Halogen-free sheathFixed, control cabinet
BS EN 60702-1 — cable cross-section
BS EN 60702-1BS EN 60702-1 Mineral-Insulated Metal-Sheathed Power Cable
0.6/1 kV
Fixed, control cabinet
EN / HDHalogen-free
0.6/1 kV, EN / HD, Halogen-free sheathFixed, control cabinet
S07HXHX — cable cross-section
S07HXHXS07HXHX Halogen-Free Cross-Linked Elastomer Flexible Power &
300/500 V
Fixed, control cabinet
IECHalogen-free
300/500 V, IEC, Halogen-free sheathFixed, control cabinet
BS 7629-1 — cable cross-section
BS 7629-1BS 7629-1 Screened Fire-Resistant Alarm Cable
300/500 V
Fixed, control cabinet
BSHalogen-free
300/500 V, BS, Halogen-free sheathFixed, control cabinet
FPLP — cable cross-section
FPLPFPLP Plenum Fire Alarm Cable
300/500 V
Fixed, control cabinet
UL / CSAFluoropolymer
300/500 V, UL / CSA, Fluoropolymer sheathFixed, control cabinet
FPLR — cable cross-section
FPLRFPLR Riser Fire Alarm Cable
300/500 V
Fixed, control cabinet
UL / CSAPVC
300/500 V, UL / CSA, PVC sheathFixed, control cabinet
Securiton SEC 15 / SEC 20 — cable cross-section
Securiton SEC 15 / SEC 20Securiton SEC 15 / SEC 20 Copper-Tube Sensing Element Linear Heat
300/500 V
Fixed, control cabinet
IECPE
300/500 V, IEC, PE sheathFixed, control cabinet

Fiber-optic cables

Single-mode and multimode fibre cables for reels, festoons and moving equipment.

11 cables
BRUsens DTS AHFO — cable cross-section
BRUsens DTS AHFOBRUsens DTS AHFO Distributed Temperature Sensing Fibre Cable
—
Motorised reel, festoon
IECHalogen-free
—, IEC, Halogen-free sheathMotorised reel, festoon
BRUsens DTS BSSA N — cable cross-section
BRUsens DTS BSSA NBRUsens DTS BSSA N Non-Metallic Stainless-Tube Temperature
—
Motorised reel, festoon
IECHalogen-free
—, IEC, Halogen-free sheathMotorised reel, festoon
BRUsens DTS BSTE / BSSA M — cable cross-section
BRUsens DTS BSTE / BSSA MBRUsens DTS BSTE / BSSA M Armoured Distributed Temperature
—
Motorised reel, festoon
IECHalogen-free
—, IEC, Halogen-free sheathMotorised reel, festoon
OPPC — cable cross-section
OPPCOPPC Optical Phase Conductor (OPPC) Overhead Power Transmission
18/30 kV – 64/110 kV
Motorised reel, festoon
IECRubber
18/30 kV – 64/110 kV, IEC, Rubber sheathMotorised reel, festoon
SMPTE 311M — cable cross-section
SMPTE 311MSMPTE 311M Hybrid Fibre-Optic and Power HD Broadcast Camera Cable
300/500 V
Motorised reel, festoon
IECPUR
300/500 V, IEC, PUR sheathMotorised reel, festoon
Sirocco / SiroccoHD / SiroccoXT — cable cross-section
Sirocco / SiroccoHD / SiroccoXTSirocco / SiroccoHD / SiroccoXT Air-Blown Microduct Fibre Optic
—
Motorised reel, festoon
IECPE
—, IEC, PE sheathMotorised reel, festoon
SiroccoHYBRID — cable cross-section
SiroccoHYBRIDSiroccoHYBRID Composite Fibre-Optic and Copper Power Air-Blown
300 V
Motorised reel, festoon
IECHalogen-free
300 V, IEC, Halogen-free sheathMotorised reel, festoon
Industrial Breakout Fiber Optic Cable — cable cross-section
Industrial Breakout Fiber Optic CableIndustrial Breakout Fiber Optic Cable
—
Motorised reel, festoon
IECPUR
—, IEC, PUR sheathMotorised reel, festoon
Armoured Loose-Tube Fiber Optic Cable — cable cross-section
Armoured Loose-Tube Fiber Optic CableArmoured Loose-Tube Fiber Optic Cable
—
Motorised reel, festoon
IECHalogen-free
—, IEC, Halogen-free sheathMotorised reel, festoon
ADSS — cable cross-section
ADSSADSS All-Dielectric Self-Supporting Fiber Optic Cable
—
Motorised reel, festoon
IECPE
—, IEC, PE sheathMotorised reel, festoon
OPGW — cable cross-section
OPGWOPGW Optical Ground Wire
—
Motorised reel, festoon
IECRubber
—, IEC, Rubber sheathMotorised reel, festoon

Instrumentation cables

Pair- and triad-screened cables for measurement and instrument circuits.

2 cables
NEK 606 BFOU / RFOU — end cross section
NEK 606 BFOU / RFOUNEK 606 BFOU and RFOU Offshore Oil & Gas Cable
0.6/1 kV
Fixed, furnace & kiln, control cabinet, offshore & shipboard
NEK 606Halogen-free
0.6/1 kV, NEK 606, Halogen-free sheathFixed, furnace & kiln, control cabinet, offshore & shipboard
BS 7917 AIS FR / ACS FR — cable cross-section
BS 7917 AIS FR / ACS FRBS 7917 AIS FR / ACS FR Armoured Offshore Instrumentation Cable
300/500 V
Fixed, offshore & shipboard
IECHalogen-free
300/500 V, IEC, Halogen-free sheathFixed, offshore & shipboard

Industrial data & RF cables

PROFINET, PROFIBUS, CAN bus, RS-485 and coaxial cables for industrial networks.

1 cable
KNX / EIB — cable cross-section
KNX / EIBKNX / EIB KNX/EIB Building Automation Cable
300 V
Fixed, control cabinet
IECHalogen-free
300 V, IEC, Halogen-free sheathFixed, control cabinet

Control cables

Multicore control and signal cables for machine and system circuits.

2 cables
J-Y(st)Y — cable cross-section
J-Y(st)YJ-Y(st)Y Screened Installation Cable
300/500 V
Free-hanging, fixed
IECPVC
300/500 V, IEC, PVC sheathFree-hanging, fixed
J-H(st)H — cable cross-section
J-H(st)HJ-H(st)H Halogen-Free Installation Cable
300/500 V
Free-hanging, fixed
IECHalogen-free
300/500 V, IEC, Halogen-free sheathFree-hanging, fixed

Power & connection cables

From 100 V welding leads to 45 kV feeders, with portable cords, EV charging and solar cables.

20 cables
H01N2-D — cable cross-section
H01N2-DH01N2-D Welding Cable
100/100 V – 450/750 V
Trailing, fixed
EN / HDRubber
100/100 V – 450/750 V, EN / HD, Rubber sheathTrailing, fixed
74C068 SH P K1 NA — cable cross-section
74C068 SH P K1 NA74C068 SH P K1 NA Nuclear K1 Class 1E LV Power Cable
300/500 V
Trailing, fixed
IECHalogen-free
300/500 V, IEC, Halogen-free sheathTrailing, fixed
0361TQ — cable cross-section
0361TQ0361TQ HOFR Welding Cable
100/100 V – 450/750 V
Trailing, fixed
BSPE
100/100 V – 450/750 V, BS, PE sheathTrailing, fixed
(N)TMCGC11Y — cable cross-section
(N)TMCGC11Y(N)TMCGC11Y Single-Core MV PUR-Sheathed Cable
0.6/1 kV
Fixed
IECPUR
0.6/1 kV, IEC, PUR sheathFixed
RG7H1R — cable cross-section
RG7H1RRG7H1R Single-Core HEPR-Insulated MV Cable
3.6/6 kV – 12/20 kV
Fixed
UL / CSAPVC
3.6/6 kV – 12/20 kV, UL / CSA, PVC sheathFixed
RG7H1OR — cable cross-section
RG7H1ORRG7H1OR Three-Core HEPR-Insulated MV Cable
3.6/6 kV – 12/20 kV
Fixed
UL / CSAPVC
3.6/6 kV – 12/20 kV, UL / CSA, PVC sheathFixed
RG7OZR — cable cross-section
RG7OZRRG7OZR Three-Core Armoured HEPR Power Cable
3.6/6 kV – 12/20 kV
Fixed
IECPVC
3.6/6 kV – 12/20 kV, IEC, PVC sheathFixed
RG7H1OZR — cable cross-section
RG7H1OZRRG7H1OZR Three-Core Screened Armoured MV Cable
3.6/6 kV – 12/20 kV
Fixed
IECPVC
3.6/6 kV – 12/20 kV, IEC, PVC sheathFixed
Type MV-105 Flexible Single-Conductor — cable cross-section
Type MV-105 Flexible Single-ConductorType MV-105 Flexible Single-Conductor
3.6/6 kV – 12/20 kV
Fixed
UL / CSAHalogen-free
3.6/6 kV – 12/20 kV, UL / CSA, Halogen-free sheathFixed
Type MV-90 / MV-105 Distribution — cable cross-section
Type MV-90 / MV-105 DistributionType MV-90 / MV-105 Distribution MV-90/MV-105 Medium-Voltage
3.6/6 kV – 12/20 kV
Fixed
UL / CSAPVC
3.6/6 kV – 12/20 kV, UL / CSA, PVC sheathFixed
EV ProInstall Cat6A — cable cross-section
EV ProInstall Cat6AEV ProInstall Cat6A
0.6/1 kV
Trailing, fixed
IECHalogen-free
0.6/1 kV, IEC, Halogen-free sheathTrailing, fixed
CICC Superconducting Conductor — cable cross-section
CICC Superconducting ConductorCICC Superconducting Conductor
300/500 V
Trailing, fixed
IECRubber
300/500 V, IEC, Rubber sheathTrailing, fixed
CORC Cable — cable cross-section
CORC CableCORC Cable Conductor on Round Core (CORC) High-Temperature
300/500 V
Trailing, fixed
IECFluoropolymer
300/500 V, IEC, Fluoropolymer sheathTrailing, fixed
ECTFE-HMWPE Cathodic Protection Cable — cable cross-section
ECTFE-HMWPE Cathodic Protection CableECTFE-HMWPE Cathodic Protection Cable
300/500 V
Trailing, fixed
IECPE
300/500 V, IEC, PE sheathTrailing, fixed
HMWPE Cathodic Protection Cable — cable cross-section
HMWPE Cathodic Protection CableHMWPE Cathodic Protection Cable
300/500 V
Trailing, fixed
IECPE
300/500 V, IEC, PE sheathTrailing, fixed
HTS Roebel Cable — cable cross-section
HTS Roebel CableHTS Roebel Cable Transposed REBCO High-Temperature
300/500 V
Trailing, fixed
IECFluoropolymer
300/500 V, IEC, Fluoropolymer sheathTrailing, fixed
Nemtek AH-UC1.6 / AH-UC2.5 — cable cross-section
Nemtek AH-UC1.6 / AH-UC2.5Nemtek AH-UC1.6 / AH-UC2.5 Double-Insulated High-Voltage
300/500 V
Trailing, fixed
IECPE
300/500 V, IEC, PE sheathTrailing, fixed
N2XH — cable cross-section
N2XHN2XH LSZH Power Cable
0.6/1 kV
Fixed
DIN VDEHalogen-free
0.6/1 kV, DIN VDE, Halogen-free sheathFixed
Three-Phase HTS Power Cable — cable cross-section
Three-Phase HTS Power CableThree-Phase HTS Power Cable
300/500 V
Trailing, fixed
IECRubber
300/500 V, IEC, Rubber sheathTrailing, fixed
Type SC / CSA PPC — cable cross-section
Type SC / CSA PPCType SC / CSA PPC UL Type SC / CSA PPC Entertainment Stage
300/500 V
Trailing, fixed
IECRubber
300/500 V, IEC, Rubber sheathTrailing, fixed

Rubber cables

Rubber-insulated, rubber-sheathed cables for mobile and heavy-duty service.

4 cables
H07RN8-F — end cross section
H07RN8-FH07RN8-F 450/750 V Submersible Pump Rubber Cable
450/750 V
Trailing, free-hanging (limited), fixed, submerged
DIN VDERubber
450/750 V, DIN VDE, Rubber sheathTrailing, free-hanging (limited), fixed, submerged
H05RR-F — cable cross-section
H05RR-FH05RR-F Rubber Flexible Cable
300/500 V
Motorised reel, trailing
IECRubber
300/500 V, IEC, Rubber sheathMotorised reel, trailing
H07ZZ-F — cable cross-section
H07ZZ-FH07ZZ-F Halogen-Free Rubber Cable
300/500 V
Motorised reel, trailing
IECHalogen-free
300/500 V, IEC, Halogen-free sheathMotorised reel, trailing
NSHXAFÖ — end cross section
NSHXAFÖNSHXAFÖ 1.8/3 kV Halogen-Free Single-Core Cable
1.8/3 kV – 3.6/6 kV
Fixed, control cabinet, motor & traction leads
DIN VDEHalogen-free
1.8/3 kV – 3.6/6 kV, DIN VDE, Halogen-free sheathFixed, control cabinet, motor & traction leads

Choosing building & fire safety cables

Four things decide most selections. Our engineers check the rest against your application.

01 · Mechanical duty & installation profile

  • Match minimum bending radius, travel speed, and tensile load to the active duty profile (Motorised monospiral reel, Festoon & line chain, Trailing & towing, Free-hanging vertical run).
  • For continuous reeling, festoon, or drag-chain motion, specify fine-stranded Class 5/6 copper conductors with central strain-relief or anti-torsion braid.

02 · Rated voltage & cable family scope

  • This collection spans Fire-resistant & fire alarm cables, Fiber-optic cables, Instrumentation cables, Industrial data & RF cables, grouped below so power feeders, control circuits, and data/optical links can be specified side by side.
  • Account for voltage drop, ambient temperature derating, and symmetrical EMC screening on long runs or VFD motor drives.

03 · Standards compliance & outer sheath compound

  • Verify the governing regional or industry standard required by the project specification (IEC, VDE/DIN, UL, BS, ICEA/MSHA, etc.).
  • Use the outer-sheath filter to lock in PUR, heavy-duty EPR/PCP rubber, or low-smoke zero-halogen (LSZH) compounds for oil, abrasion, or fire safety.
Filter the range by standard

Questions buyers ask

Not covered here? Send your drawing and an engineer replies within 2 business hours.

Ask on WhatsApp
What rated voltages are available in the Building & Fire Safety Cables category?

Rated voltages run from 100/100 V to 110 kV across 38 of the 58 products. The most common rating is 0.6/1 kV, listed for 10 products.

Which standards do the products in the Building & Fire Safety Cables category reference?

The products reference IEC Standard (52 products), VDE / DIN Standard (18 products), UL Standard (10 products), BS 6708 (9 products), ICEA Standard (3 products), AS/NZS Standard (1 product), and NEK 606 Standard (1 product).

Are PDF datasheets available for the products in the Building & Fire Safety Cables category?

Yes. All 58 products have a PDF datasheet, linked from each product card and product page.

Engineering reference

Background on how building & fire safety cables are built, rated and specified.

Read the full reference

The Building & Fire Safety Cables collection brings together 58 industrial cable models across Fire-resistant & fire alarm cables, Fiber-optic cables, Instrumentation cables, Industrial data & RF cables, Control cables, Power & connection cables. Fire-resistant circuit-integrity cables, alarm wiring and low-smoke halogen-free feeders for public buildings and tunnels.

Use the multi-facet filter bar and duty matrix view to compare rated voltage, governing standard, outer sheath compound, and mechanical duty ratings side by side, or add candidate models to a combined engineering enquiry.

Compare cables

Voltage
Standard
Sheath
Features
Typical use

Highlighted rows differ between the selected cables.

Filters

Duty

Voltage

Standard

Sheath

Features