Switchgear & control cabinet wiring
Per-core semiconductive silicone stress control suppresses partial discharge in compact 6-channel 10 kVDC racks.
Product
HSC-10-6SSSA 10 kVDC multicore high-voltage DC cable combining 6 × AWG 20 tinned copper conductors, per-core semiconductive silicone stress control, 10 kVDC silicone primary insulation, tinned copper EMC braid screen and a silicone sheath.
Typical values for this cable type, based on IEC 60502 / DIN VDE 0250 — confirmed in the datasheet and quotation for your order.
Application fit
HSC-10-6SSSA 10 kVDC multicore high-voltage DC cable combining 6 × AWG 20 tinned copper conductors, per-core semiconductive silicone stress control, 10 kVDC silicone primary insulation, tinned copper EMC braid screen and a silicone sheath.
Per-core semiconductive silicone stress control suppresses partial discharge in compact 6-channel 10 kVDC racks.
All-silicone dielectric and outer sheath operate continuously from −50 °C up to +180 °C.
Each of the 6 cores is individually rated for 10 kVDC both core-to-core and core-to-grounded-screen.
Precision high-voltage DC instrumentation feeder; not designed for heavy mechanical crane drums.
ARG7H1ORConstruction
Shown: HSC-10-6SSSA (IEC 60502 / DIN VDE 0250) featuring hvdc conductors (6xawg 20), per-core stress control layer and overall screen & silicone jacket (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | HVDC Conductors (6xAWG 20) | Six 19 x 0.203 mm (0.61 mm², AWG 20) concentric stranded tinned copper conductors laid around the central coreIEC 60502 / DIN VDE 0250 |
| 2 | Per-Core Stress Control Layer | Extruded black semiconductive silicone elastomer stress-control layer over each individual conductor eliminating corona onsetIEC 60502 / DIN VDE 0250 |
| 3 | Per-Core HV Silicone Dielectric | High-voltage silicone rubber primary insulation over each core (core OD 3.7 mm, rated 10 kVDC core-to-core and core-to-screen)IEC 60502 / DIN VDE 0250 |
| 4 | Central Support Element | Silicone-sheathed fiberglass central strength and geometry support element stabilizing the 6-core circular layIEC 60502 / DIN VDE 0250 |
| 5 | Overall Screen & Silicone Jacket | Polyester binder tape, overall tinned copper wire braid screen, and flexible silicone rubber outer sheath (OD 14.5 mm)IEC 60502 / DIN VDE 0250 |
Built to IEC 60502 / DIN VDE 0250 with hvdc conductors (6xawg 20) and overall screen & silicone jacket
Available in custom drum lengths, core counts or factory-terminated assemblies
Supplied with EN 10204 3.1 routine electrical, dielectric & dimensional inspection report
Technical data
Sizes
Manufactured to IEC 60502 / DIN VDE 0250 for heavy-duty industrial and specialty engineering systems.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Weight ≈ kg/km | Tensile load kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| HSC-10-6SSSA Construction Schedule (−50…+180 °C) | |||||||
| HSC-10-4SSSA (4×AWG 20, 10 kVDC) | 4 × AWG 20 (0.61 mm²) | 19×0.203 mm tinned Cu + semicon | 11.2 | 165 | 0.5 | 90 | |
| HSC-10-6SSSA (6×AWG 20, 10 kVDC) | 6 × AWG 20 (0.61 mm²) | 19×0.203 mm tinned Cu + semicon | 13.6 | 235 | 0.8 | 110 | |
| HSC-10-8SSSA (8×AWG 20, 10 kVDC) | 8 × AWG 20 (0.61 mm²) | 19×0.203 mm tinned Cu + semicon | 15.8 | 310 | 1.0 | 130 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Capacity | Operating temp. |
|---|---|---|---|
| 4 × AWG 20 (10 kVDC) | 32.10 | 10 kVDC (25 kVDC test) | −50…+180 °C |
| 6 × AWG 20 (10 kVDC) | 32.10 | 10 kVDC (25 kVDC test) | −50…+180 °C |
| 8 × AWG 20 (10 kVDC) | 32.10 | 10 kVDC (25 kVDC test) | −50…+180 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance & dimensional verification (IEC 60502 / DIN VDE 0250) | Electrical parameters and outer diameter within IEC 60502 / DIN VDE 0250 tolerances | Every manufactured drum / length |
| High-voltage dielectric & insulation resistance test (IEC 60502 / DIN VDE 0250) | Zero dielectric breakdown and verified insulation resistance over full length | Every manufactured drum / length |
| Sample tests | ||
| Thermal ageing, mechanical flexing & environmental qualification (IEC 60502 / DIN VDE 0250) | Verified structural and dielectric integrity across −50…+180 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.