Offshore platform & shipboard deck trays
Halogen-free SHF1/SHF2 or mud-resistant thermoset jacket withstands marine salt mist, oil and deck weathering.
Product
BFOU (M) P6/P7/P16 3.6/6–18/30 kV NEK 606 Fire-Resistant Offshore MV Power Cable (NEK TS 606 / IEC 60092-354) engineered for 3.6/6 kV – 18/30 kV service across -40 to +90 °C (min. bend radius 12 × OD).
Typical values for this cable type, based on NEK TS 606 Code P6/P7/P16 / IEC 60092-354 / IEC 60331-21 — confirmed in the datasheet and quotation for your order.
Application fit
BFOU (M) P6/P7/P16 3.6/6–18/30 kV NEK 606 Fire-Resistant Offshore MV Power Cable (NEK TS 606 / IEC 60092-354) engineered for 3.6/6 kV – 18/30 kV service across -40 to +90 °C (min. bend radius 12 × OD).
Halogen-free SHF1/SHF2 or mud-resistant thermoset jacket withstands marine salt mist, oil and deck weathering.
Approved for bulkheads, cable trays, ladders and hull penetrations on commercial vessels and offshore units.
Metallic braid armour and cross-linked EPR/XLPE/XLPO insulation handle heavy mechanical and thermal duty.
Stranded copper or tinned copper conductors terminate cleanly into marine switchboards, thrusters and transformers.
Armoured shipboard and offshore feeder cable is not designed for high-cycle automation drag chains.
Use Drag-Chain Servo CableConstruction
Shown: BFOU (M) P6/P7/P16 3.6/6-18/30 KV (NEK 606 MV) (NEK TS 606 Code P6/P7/P16 / IEC 60092-354 / IEC 60331-21) featuring tinned copper + mica fire barrier (b), triple-extruded hepr mv insulation (f) and orange shf2-mud fire-safe mv jacket (u) (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Tinned Copper + Mica Fire Barrier (B) | Class 2/5 tinned copper with phlogopite mica fire-resistant barrier |
| 2 | Triple-Extruded HEPR MV Insulation (F) | Conductor screen + 90 °C HEPR dielectric + strippable insulation screen |
| 3 | Copper Tape Phase Metallic Screen | Overlapped annealed copper tape screen on each phase |
| 4 | SHF2 Inner Bedding & TCWB Armour (O) | Halogen-free thermoset inner sheath + tinned copper wire braid |
| 5 | Orange SHF2-MUD Fire-Safe MV Jacket (U) | NEK TS 606 P6/P7/P16 mud- and fire-resistant outer sheath |
Built to NEK TS 606 Code P6/P7/P16 / IEC 60092-354 / IEC 60331-21 with tinned copper + mica fire barrier (b) and orange shf2-mud fire-safe mv jacket (u)
Available in custom continuous shipboard/offshore drum lengths or with marine EMC cable glands
Supplied with EN 10204 3.1 routine dielectric, conductor resistance & flame/fire test report
Technical data
Sizes
Manufactured to NEK TS 606 Code P6/P7/P16 / IEC 60092-354 / IEC 60331-21 for shipboard, offshore platform, drilling rig and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| BFOU (M) P6/P7/P16 3.6/6-18/30 KV (NEK 606 MV) Construction Schedule (−40…+90 °C) | |||||||
| BFOU 3×50 mm² MV | 3 × 50 mm² | IEC 60228 Class 2/5 Cu/SnCu | 42.5 | 2,980 | 22.5 | 510 | |
| BFOU 3×95 mm² MV | 3 × 95 mm² | IEC 60228 Class 2/5 Cu/SnCu | 51.8 | 4,690 | 42.8 | 620 | |
| BFOU 3×150 mm² MV | 3 × 150 mm² | IEC 60228 Class 2/5 Cu/SnCu | 61.2 | 6,840 | 67.5 | 735 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 3 × 50 mm² | 0.39 | 3.6/6 kV – 18/30 kV (195 A) | −40…+90 °C |
| 3 × 95 mm² | 0.19 | 3.6/6 kV – 18/30 kV (285 A) | −40…+90 °C |
| 3 × 150 mm² | 0.12 | 3.6/6 kV – 18/30 kV (365 A) | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (NEK TS 606 Code P6/P7/P16 / IEC 60092-354 / IEC 60331-21) | DC resistance at 20 °C / optical attenuation and outer diameter within NEK TS 606 Code P6/P7/P16 / IEC 60092-354 / IEC 60331-21 tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (NEK TS 606 Code P6/P7/P16 / IEC 60092-354 / IEC 60331-21) | Zero dielectric breakdown and verified insulation resistance for 3.6/6 kV – 18/30 kV rating | Every manufactured drum length |
| Sample tests | ||
| Flame, fire integrity, oil/mud & mechanical qualification (NEK TS 606 Code P6/P7/P16 / IEC 60092-354 / IEC 60331-21) | Verified flame/fire performance, fluid resistance and thermal stability across −40…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.