Socapex 19G1.5 / 19G2.5 300/500V Stage Lighting Multicore CableSocapex 19G1.5 / 19G2.5 300/500V Stage Lighting Multicore Cable manufactured to BS EN 50525-2-11 / Socapex 19-Pin, rated 300/500 V and -15°C to +70°C with a 6 × OD minimum bending radius for industrial automation & manufacturing installations.

Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.

Flame-retardant
Oil-resistant
Approved
Order designation
Socapex 19G1.5 / 19G2.5 300/500V Stage (19G2.5 mm²)
Outer diameter
21.5 mm
Cable weight
1,086 kg/km
Min. bend radius
129 mm
Conductor & shield
Class 5 Flexible Plain Copper
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
300/500 V
BS EN 50525-2-11 / Socapex 19-Pin
Temperature
-15°C to +70°C
Fixed / flex duty
Min. bend radius
6 × OD
21.5–29.7 mm
Screening
Unshielded
Fixed / flex duty
Outer sheath
Industrial PVC
Oil & sunlight resistant
Core / size range
3 sizes
3 standard configurations

Typical values for this cable type, based on Reference specification per BS EN 50525-2-11 / Socapex 19-Pin (Socapex 19G1.5 / 19G2.5 300/500V Stage) — confirmed in the datasheet and quotation for your order.

Application fit

Is Socapex 19G1.5 / 19G2.5 300/500V Stage right for your machine?

Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.

Fixed installation

Suitable

Approved for cable tray, duct, direct burial or clipped fixed installations per applicable wiring regulations.

Motor stator, traction & converter leads

Suitable

Flexible stranded conductors withstand equipment vibration, mobile hook-ups and routine flexing.

Energy chain / drag chain

With conditions

Fixed or moderate-flex construction; for continuous high-acceleration drag chains, select a dedicated Class 6 chain cable.

Offshore platform & shipboard deck trays

Suitable

Outer sheath compound resists industrial oils, moisture ingress, abrasion and outdoor weathering.

Vertical / spreader reel

Not suitable

Not intended for high-tension crane spreader reeling drums; select a dedicated 2PNCT or 3PNCT reeling cable.

Use TRA 0.6/1 kV PUR Reeling Cable

Dual-tier power & PLC tray

Suitable

Screened 300/500 V PVC construction suppresses electromagnetic interference on shared industrial power and PLC signal trays.

Typical machinesIndustrial Automation CablePower distribution & utility networksRailways, tunnels & public infrastructureProcess instrumentation & oil/gas skidsIndustrial automation & control cabinetsRenewable energy, marine & heavy industry

Construction

Layer by layer

Cross-section colours are aligned to the supplied product cutaway; layer dimensions follow the reference specification.

Socapex 19G1.5 / 19G2.5 300/500V Stage – Layered cable cutaway
Layer cutaway
#LayerMaterial & reference
1Conductor19G2.5 mm² (18 Black Numbered Cores + 1 Green/Yellow Earth) Class 5 Flexible Cu
2Insulation & Core IdentificationFlexible stage-lighting black white-numbered PVC insulation (2.5 mm² Class 5 Cu)
3Screen / Bedding / Armour LayerNon-woven textile separator wrap
4Outer Protective SheathMatte Black abrasion-resistant stage-lighting PVC outer sheath (OD 21.5 mm)

19G2.5 mm²

Class 5 Flexible Plain Copper · Outer diameter 21.5 mm

19G4 mm²

Class 5 Flexible Plain Copper · Outer diameter 25.4 mm

19G6 mm²

Class 5 Flexible Plain Copper · Outer diameter 29.7 mm

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on Reference specification per BS EN 50525-2-11 / Socapex 19-Pin (Socapex 19G1.5 / 19G2.5 300/500V Stage). Values for your order are confirmed in the datasheet and quotation.

Electrical

Nominal / reference voltage
300/500 V
Conductor & core insulation
19G2.5 mm² (18 Black Numbered Cores + 1 Green/Yellow Earth) Class 5 Flexible Cu · Flexible stage-lighting black white-numbered PVC insulation (2.5 mm² Class 5 Cu)
Routine dielectric / continuity test
100% factory drum spark & continuity verified

Thermal

Operating temperature range
-15°C to +70°C
Short-circuit / peak thermal limit
+160 °C to +250 °C (5 s conductor thermal limit)
Flame & fire performance
BS EN 50525-2-11 / Socapex 19-Pin

Mechanical

Minimum bending radius
6 × OD
Screening / armour architecture
Non-woven textile separator wrap
Outer sheath material & colour
Matte Black abrasion-resistant stage-lighting PVC outer sheath (OD 21.5 mm)

Reference standards

Reference standard
BS EN 50525-2-11 / Socapex 19-Pin
Hazardous Substance Compliance
CE, UKCA, RoHS 2 (2011/65/EU) & REACH SVHC compliant
Quality & Batch Traceability
EN 10204 3.1 Factory Inspection Certificate

Sizes

Sizes & engineering data

Representative configurations from the series specification; select a row to prefill the quotation tool.

All sizes
ConfigurationConductor & shieldInsulation / wallOuter sheathOuter diameter
mm
Min. bend radius
mm
Max. conductor resistance @ 20 °C
Ω/km
Copper weight
kg/km
Cable weight
kg/km
Key electrical / optical ratingPart designationEnquiry
Socapex 19G1.5 / 19G2.5 300/500V Stage
19G2.5 mm²Class 5 Flexible Plain CopperFlexible stage-lighting black white-numbered PVC insulationIndustrial PVC21.51297.24564.71,08625 ASocapex 19G1.5 / 19G2.5 300/500V Stage (19G2.5 mm²)
19G4 mm²Class 5 Flexible Plain CopperFlexible stage-lighting black white-numbered PVC insulationIndustrial PVC25.41524.53786.81,51334 ASocapex 19G1.5 / 19G2.5 300/500V Stage (19G4 mm²)
19G6 mm²Class 5 Flexible Plain CopperFlexible stage-lighting black white-numbered PVC insulationIndustrial PVC29.71783.021,075.92,06943 ASocapex 19G1.5 / 19G2.5 300/500V Stage (19G6 mm²)
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Dimensions and weights are nominal manufacturing targets subject to standard production tolerances.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance & continuityWithin maximum Ω/km limit at 20 °C per IEC 60228 / BS EN 60228Every manufactured drum length
Dielectric withstand / spark testNo breakdown across insulation, screen or armourEvery manufactured drum length
Sample tests
Vertical flame propagation & jacket qualificationSelf-extinguishing and compliant with reference standard limitsType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

BS EN 50525-2-11 / Socapex 19-Pin CompliantEN 10204 3.1 Factory Test CertificateCE, UKCA, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

SOCAPEX 19G1.5 / 19G2.5 300/500V STAGE LIGHTING MULTICORE CABLE / TEBAOFLEX.COM — sequential metre marking
Delivery form
Heavy-duty export fumigated wooden drums or steel reels with moisture-sealed ends
Standard lengths
250 m, 500 m, 1000 m continuous drum lengths or custom cut-to-length runs
MOQ
100 m (standard configurations) · 300 m (custom builds)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-11-04
Updated
2026-11-04

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What applications is Socapex 19G1.5 / 19G2.5 300/500V Stage designed for?
Socapex 19G1.5 / 19G2.5 300/500V Stage is engineered for industrial automation & manufacturing installations under BS EN 50525-2-11 / Socapex 19-Pin, operating over -15°C to +70°C with a minimum bending radius of 6 × OD.
How is Socapex 19G1.5 / 19G2.5 300/500V Stage constructed across its layers?
Its 4-layer architecture combines 19G2.5 mm² (18 Black Numbered Cores + 1 Green/Yellow Earth) Class 5 Flexible Cu with Flexible stage-lighting black white-numbered PVC insulation (2.5 mm² Class 5 Cu), Non-woven textile separator wrap and Matte Black abrasion-resistant stage-lighting PVC outer sheath (OD 21.5 mm).
What standards and routine factory tests apply to Socapex 19G1.5 / 19G2.5 300/500V Stage?
Every manufactured drum is tested to BS EN 50525-2-11 / Socapex 19-Pin for conductor continuity, dielectric voltage withstand and sheath integrity, supplied with an EN 10204 3.1 inspection certificate.
What sizes and drum lengths are available for Socapex 19G1.5 / 19G2.5 300/500V Stage?
Representative sizes include 19G2.5 mm², 19G4 mm² and 19G6 mm², supplied on 250 m, 500 m or 1,000 m export drums or custom cut lengths.
Which technical documents are available?
Reference files are provided for project screening. Final parameters and the applicable document package are confirmed during quotation.

Request a quote

Get an engineering quote for Socapex 19G1.5 / 19G2.5 300/500V Stage

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

Socapex 19G1.5 / 19G2.5 300/500V Stage Lighting Multicore Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote