Fixed installation
Approved for cable tray, duct, direct burial or clipped fixed installations per applicable wiring regulations.
Product
Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.
Typical values for this cable type, based on Reference specification per HD 632 / IEC 60840 (A2XS(FL)2Y 26/45kV–76/132kV HD 632) — confirmed in the datasheet and quotation for your order.
Application fit
Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.
Approved for cable tray, duct, direct burial or clipped fixed installations per applicable wiring regulations.
Flexible stranded conductors withstand equipment vibration, mobile hook-ups and routine flexing.
Fixed or moderate-flex construction; for continuous high-acceleration drag chains, select a dedicated Class 6 chain cable.
Outer sheath compound resists industrial oils, moisture ingress, abrasion and outdoor weathering.
Not intended for high-tension crane spreader reeling drums; select a dedicated 2PNCT or 3PNCT reeling cable.
Use TRA 0.6/1 kV PUR Reeling CableHigh-dielectric 76/132 kV XLPE/HDPE construction feeds medium- and high-voltage substation duct banks, transformer bays, and utility feeders.
Construction
Cross-section colours are aligned to the supplied product cutaway; layer dimensions follow the reference specification.

| # | Layer | Material & reference |
|---|---|---|
| 1 | Conductor | 1×300 mm² RM Watertight Compacted Al |
| 2 | Insulation & Core Identification | HV super-clean XLPE dielectric (300 mm² RM Aluminium, 26/45 kV) |
| 3 | Screen / Bedding / Armour Layer | Semi-conducting longitudinal water-swellable tape (F) + Helical copper wire screen + equalising copper tape + Copolymer-coated aluminium foil radial moisture barrier (L) |
| 4 | Outer Protective Sheath | Black high-density Polyethylene (HDPE ST7) outer sheath (OD 58.0 mm) |
Class 2 Watertight Compacted Aluminium · Outer diameter 58.0 mm
Class 2 Watertight Compacted Aluminium · Outer diameter 68.4 mm
Class 2 Watertight Compacted Aluminium · Outer diameter 80.0 mm
Technical data
Sizes
Representative configurations from the series specification; select a row to prefill the quotation tool.
| Configuration | Conductor & shield | Insulation / wall | Outer sheath | Outer diameter mm | Min. bend radius mm | Max. conductor resistance @ 20 °C Ω/km | Conductor weight kg/km | Cable weight kg/km | Key electrical / optical rating | Part designation | Enquiry |
|---|---|---|---|---|---|---|---|---|---|---|---|
| A2XS(FL)2Y 26/45kV–76/132kV HD 632 | |||||||||||
| 1×300 mm² | Class 2 Watertight Compacted Aluminium | HV super-clean XLPE dielectric | Outdoor PE | 58.0 | 870 | 0.09 | 2,109.4 | 5,551 | 385 A | A2XS(FL)2Y 26/45kV–76/132kV HD 632 (1×300 mm²) | |
| 1×400 mm² | Class 2 Watertight Compacted Aluminium | HV super-clean XLPE dielectric | Outdoor PE | 68.4 | 1,026 | 0.07 | 2,937.0 | 7,729 | 445 A | A2XS(FL)2Y 26/45kV–76/132kV HD 632 (1×400 mm²) | |
| 1×500 mm² | Class 2 Watertight Compacted Aluminium | HV super-clean XLPE dielectric | Outdoor PE | 80.0 | 1,200 | 0.06 | 4,017.0 | 10,571 | 515 A | A2XS(FL)2Y 26/45kV–76/132kV HD 632 (1×500 mm²) | |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance & continuity | Within maximum Ω/km limit at 20 °C per IEC 60228 / BS EN 60228 | Every manufactured drum length |
| Dielectric withstand / spark test | No breakdown across insulation, screen or armour | Every manufactured drum length |
| Sample tests | ||
| Vertical flame propagation & jacket qualification | Self-extinguishing and compliant with reference standard limits | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.