Contact
submarine & offshore power composite cableIEC 60502-1 / FERE Subsea EO0.6/1 kV – 1.8/3 kV (-25 to +90 °C)Bitumen-Filled Single Steel Wire Arm

FERE 0.6/1 kV & 1.8/3 kV 3-Core + 12F G.652D Single Steel-Wire Armoured Subsea EO CableIEC 60502-1 / FERE Subsea EO — 0.6/1 kV – 1.8/3 kV — -25 to +90 °C Subsea & Offshore Cable

FERE 0.6/1 kV & 1.8/3 kV 3-Core + 12F G.652D Single Steel-Wire Armoured Subsea EO Cable (IEC 60502-1 / FERE Subsea EO) engineered for 0.6/1 kV – 1.8/3 kV service across -25 to +90 °C (min. bend radius 12 × OD).

Water-resistant
Ozone, UV & moisture
Oil-resistant
Approved
Order designation
FERE 0.6 3×16+1G16 mm²
Outer Ø ≈
22.4 mm
Net weight ≈
920 kg/km
Tensile rating ≈
18.5 kN
Core / stranding
IEC 60228 Class 2/5 Cu/SnCu
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
0.6/1 kV – 1.8/3
Tested per IEC 60502-1 / FERE Subsea EO
Operating temp.
−25…+90 °C
Continuous subsea & offshore service
Min. bend radius
12 × OD
Winch sheave, chute & seabed routing
Core / conductor
Class 2 Stranded
0.6/1 kV or 1.8/3 kV XLPE insulated powe
Outer protection
Bitumen-Filled S
Corrosion-inhibited galvanized round ste
Standard
IEC 60502-1 / FE
IEC 60502-1 FERE 0.6/1 kV & 1.8/3 kV Sin

Typical values for this cable type, based on IEC 60502-1 FERE 0.6/1 kV & 1.8/3 kV Single-Armoured Subsea Electro-Optical Specification — confirmed in the datasheet and quotation for your order.

Application fit

Is FERE 0.6/1–1.8/3kV EO right for your machine?

FERE 0.6/1 kV & 1.8/3 kV 3-Core + 12F G.652D Single Steel-Wire Armoured Subsea EO Cable (IEC 60502-1 / FERE Subsea EO) engineered for 0.6/1 kV – 1.8/3 kV service across -25 to +90 °C (min. bend radius 12 × OD).

Offshore platform & shipboard deck trays

Suitable

Halogen-free SHF1/SHF2, IEEE 1580 Type P or PE/PP submarine outer serving withstands marine salt mist, drilling mud and seabed/deck duty.

Fixed installation

Suitable

Approved for submarine seabed burial, J-tube pull-in, offshore platform cable ladders and shipboard bulkhead penetrations.

Immersion & wet locations

Suitable

Extruded lead-alloy radial water barrier or cross-linked marine elastomer sheath prevents moisture ingress in subsea and wet-deck service.

Motor stator, traction & converter leads

Suitable

Compacted copper or extra-flexible Class I/K tinned copper conductors terminate cleanly into offshore switchboards, transformers and thrus

Energy chain / drag chain

Not suitable

Submarine and armoured offshore power cable is not designed for high-cycle automation drag chains.

Use Drag-Chain Servo Cable
Typical machinesMarine & Offshore CableOffshore Wind Inter-Array & Export Submarine LinksSubsea Island & Platform HV/MV Power InterconnectsOffshore Oil & Gas Drilling Rigs & FPSOsCommercial Vessels, Polar Ships & Marine Propulsion

Construction

Layer by layer

Shown: FERE 0.6/1–1.8/3kV EO (IEC 60502-1 FERE 0.6/1 kV & 1.8/3 kV Single-Armoured Subsea Electro-Optical Specification) featuring class 2 stranded copper/al cores (10-240 mm²), 12-fiber g.652d single-mode optical unit and bitumen-filled single steel wire armour (fere) (4-layer construction).

1234
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Class 2 Stranded Copper/Al Cores (10-2400.6/1 kV or 1.8/3 kV XLPE insulated power conductors
212-Fiber G.652D Single-Mode Optical UnitInterstitial optical fiber tube for buoy & farm telemetry
3Polyethylene (PE) Inner SheathWaterproof extruded PE inner bedding jacket
4Bitumen-Filled Single Steel Wire Armour Corrosion-inhibited galvanized round steel wire outer armour

FERE 0.6/1–1.8/3kV EO — Standard Subsea & Offshore Execution

Built to IEC 60502-1 FERE 0.6/1 kV & 1.8/3 kV Single-Armoured Subsea Electro-Optical Specification with class 2 stranded copper/al cores (10-240 mm²) and bitumen-filled single steel wire armour (fere)

FERE 0.6/1–1.8/3kV EO — Custom Continuous Winch / Reel Length

Available in custom continuous subsea winch, tow or seabed lengths with water-blocked terminations

FERE 0.6/1–1.8/3kV EO — Hydrostatic, Tensile & Routine Certified

Supplied with EN 10204 3.1 routine dielectric, optical OTDR / DC resistance & tensile test report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on IEC 60502-1 FERE 0.6/1 kV & 1.8/3 kV Single-Armoured Subsea Electro-Optical Specification. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
0.6/1 kV – 1.8/3 kV (IEC 60502-1 FERE 0.6/1 kV & 1.8/3 kV Single-Armoured Subsea Electro-Optical Specification)
Core / conductor construction
Class 2 Stranded Copper/Al Cores (10-240 mm²) — 0.6/1 kV or 1.8/3 kV XLPE insulated power conductors
Primary dielectric / buffering
12-Fiber G.652D Single-Mode Optical Unit — Interstitial optical fiber tube for buoy & farm telemetry

Thermal

Continuous operating temperature
−25…+90 °C (subsea & offshore duty)
Hydrostatic & thermal stability
Verified thermal and hydrostatic stability per IEC 60502-1 FERE 0.6/1 kV & 1.8/3 kV Single-Armoured Subsea Electro-Optical Specification
Storage & transport temperature
−40…+80 °C on export wooden/steel winch reel

Mechanical

Outer protection / armouring
Bitumen-Filled Single Steel Wire Armour (FERE) — Corrosion-inhibited galvanized round steel wire outer armour
Minimum bending radius
12 × OD
Armour, strength member & mechanical duty
Polyethylene (PE) Inner Sheath — Waterproof extruded PE inner bedding jacket

Resistance

Seawater, hydrostatic & hydrolysis resistance
Engineered for continuous seawater immersion, pressure cycling and hydrolysis resistance per IEC 60502-1 FERE 0.6/1 kV & 1.8/3 kV Single-Armoured Subsea Electro-Optical Specification
Oil, drilling mud & abrasion resistance
Resistant to marine hydraulic oils, salt mist, winch sheave wear and seabed abrasion per IEC 60502-1 FERE 0.6/1 kV & 1.8/3 kV Single-Armoured Subsea Electro-Optical Specification
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
IEC 60502-1 FERE 0.6/1 kV & 1.8/3 kV Single-Armoured Subsea Electro-Optical Specification
Environmental & test standards
IEC 60228 / IEC 60794 / ITU-T G.972 / IEEE 1580 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
FERE 0.6/1–1.8/3kV EO
Sheath colour & metre marking
Continuous metre-marked black outer finish (Bitumen-Filled S)
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard FERE 0.6/1–1.8/3kV EO subsea & offshore configurations

Manufactured to IEC 60502-1 FERE 0.6/1 kV & 1.8/3 kV Single-Armoured Subsea Electro-Optical Specification for subsea, oceanographic, ROV, seismic and offshore applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Breaking / tensile
kN ≈
Min. bend R
mm
Enquiry
FERE 0.6/1–1.8/3kV EO Construction Schedule (−25…+90 °C)
FERE 0.6 3×16+1G16 mm²3 × 16 + 1G16 mm² (or 1C×50 mm²)IEC 60228 Class 2/5 Cu/SnCu22.492018.5135
FERE 0.6 3×35+1G16 mm²3 × 35 + 1G16 mm² (or 1C×150 mm²)IEC 60228 Class 2/5 Cu/SnCu28.81,69032.0175
FERE 0.6 3×95+1G50 mm²3 × 95 + 1G50 mm² (or 1C×300 mm²)IEC 60228 Class 2/5 Cu/SnCu41.23,68058.0250
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour breaking loads and continuous winch/seabed lengths available per IEC 60502-1 FERE 0.6/1 kV & 1.8/3 kV Single-Armoured Subsea Electro-Optical Specification.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, optical OTDR continuity & dimensional verification (IEC 60502-1 FERE 0.6/1 kV & 1.8/3 kV Single-Armoured Subsea Electro-Optical Specification)DC resistance at 20 °C / optical attenuation and outer diameter within IEC 60502-1 FERE 0.6/1 kV & 1.8/3 kV Single-Armoured Subsea Electro-Optical Specification tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (IEC 60502-1 FERE 0.6/1 kV & 1.8/3 kV Single-Armoured Subsea Electro-Optical Specification)Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV – 1.8/3 kV ratingEvery manufactured drum length
Sample tests
Hydrostatic pressure, tensile breaking load & water-blocking qualification (IEC 60502-1 FERE 0.6/1 kV & 1.8/3 kV Single-Armoured Subsea Electro-Optical Specification)Verified subsea pressure integrity, torque-balanced tensile performance and thermal stability across −25…+90 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

IEC 60502-1 / FERE Subsea EO CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX FERE 0.6/1–1.8/3kV EO IEC 60502-1 / FERE Subsea EO 0.6/1 kV – 1.8/3 kV CE
Delivery form
Heavy-duty export fumigated wooden drums, steel oceanographic winch reels or submarine turntables
Standard lengths
500 m, 1,000 m, 3,000 m, 6,000 m or custom continuous subsea lengths
MOQ
100 m (standard configurations) · 500 m (custom subsea builds)
Lead time
2–6 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-26
Updated
2026-10-26

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define FERE 0.6/1–1.8/3kV EO (FERE 0.6/1 kV & 1.8/3 kV 3-Core + 12F G.652D Single Steel-Wire Armoured Subsea EO Cable)?
FERE 0.6/1–1.8/3kV EO (FERE 0.6/1 kV & 1.8/3 kV 3-Core + 12F G.652D Single Steel-Wire Armoured Subsea EO Cable) is manufactured in accordance with IEC 60502-1 FERE 0.6/1 kV & 1.8/3 kV Single-Armoured Subsea Electro-Optical Specification for 0.6/1 kV – 1.8/3 kV service over -25 to +90 °C. Its 4-layer construction comprises class 2 stranded copper/al cores (10-240 mm²), 12-fiber g.652d single-mode optical unit and bitumen-filled single steel wire armour (fere).
What is the minimum bending radius and operating temperature range for FERE 0.6/1–1.8/3kV EO?
The minimum bending radius for FERE 0.6/1–1.8/3kV EO is 12 × OD across its continuous operating temperature range of -25 to +90 °C, ensuring mechanical, hydrostatic and dielectric reliability in subsea and offshore service.
How are the concentric layers of FERE 0.6/1–1.8/3kV EO arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Class 2 Stranded Copper/Al Cores (10-240 mm²) — 0.6/1 kV or 1.8/3 kV XLPE insulated power conductors; (02) 12-Fiber G.652D Single-Mode Optical Unit — Interstitial optical fiber tube for buoy & farm telemetry; (03) Polyethylene (PE) Inner Sheath — Waterproof extruded PE inner bedding jacket; (04) Bitumen-Filled Single Steel Wire Armour (FERE) — Corrosion-inhibited galvanized round steel wire outer armour.
What factory test certificates are supplied with FERE 0.6/1–1.8/3kV EO?
Every production drum of FERE 0.6/1–1.8/3kV EO undergoes routine conductor resistance/OTDR continuity, high-voltage dielectric and dimensional testing per IEC 60502-1 FERE 0.6/1 kV & 1.8/3 kV Single-Armoured Subsea Electro-Optical Specification, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for FERE 0.6/1–1.8/3kV EO

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

FERE 0.6/1 kV & 1.8/3 kV 3-Core + 12F G.652D Single Steel-Wire Armoured Subsea EO Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote