Fixed installation
Approved for cable tray, duct, direct burial or clipped fixed installations per applicable wiring regulations.
Product
Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.
Typical values for this cable type, based on Reference specification per NR/PS/ELP/00008 / BS 7870 (NR/PS/ELP/00008 19/33kV–25/44kV) — confirmed in the datasheet and quotation for your order.
Application fit
Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.
Approved for cable tray, duct, direct burial or clipped fixed installations per applicable wiring regulations.
Flexible stranded conductors withstand equipment vibration, mobile hook-ups and routine flexing.
Fixed or moderate-flex construction; for continuous high-acceleration drag chains, select a dedicated Class 6 chain cable.
Outer sheath compound resists industrial oils, moisture ingress, abrasion and outdoor weathering.
Not intended for high-tension crane spreader reeling drums; select a dedicated 2PNCT or 3PNCT reeling cable.
Use WXG / WXG-D MV Reeling CableHigh-dielectric 25/44 kV XLPE/MDPE construction feeds medium- and high-voltage substation duct banks, transformer bays, and utility feeders.
Construction
Cross-section colours are aligned to the supplied product cutaway; layer dimensions follow the reference specification.

| # | Layer | Material & reference |
|---|---|---|
| 1 | Conductor | 1×185 mm² Class 1 Solid Al (or 300 mm² Cu) |
| 2 | Insulation & Core Identification | NR/PS/ELP/00008 19/33kV XLPE dielectric (185 mm² Class 1 Solid Aluminium) |
| 3 | Screen / Bedding / Armour Layer | Semi-conductive longitudinal water-blocking swellable tape + Helical copper wire screen + equalising copper tape + Bonded Aluminium/PE moisture barrier laminate |
| 4 | Outer Protective Sheath | Black MDPE outer sheath with extruded outer conductive graphite coating (OD 44.5 mm) |
Class 1/2 Aluminium · Outer diameter 44.5 mm
Class 1/2 Aluminium · Outer diameter 52.5 mm
Class 1/2 Aluminium · Outer diameter 61.4 mm
Technical data
Sizes
Representative configurations from the series specification; select a row to prefill the quotation tool.
| Configuration | Conductor & shield | Insulation / wall | Outer sheath | Outer diameter mm | Min. bend radius mm | Max. conductor resistance @ 20 °C Ω/km | Conductor weight kg/km | Cable weight kg/km | Key electrical / optical rating | Part designation | Enquiry |
|---|---|---|---|---|---|---|---|---|---|---|---|
| NR/PS/ELP/00008 19/33kV–25/44kV | |||||||||||
| 1×185 mm² | Class 1/2 Aluminium | NR/PS/ELP/00008 19/33kV XLPE dielectric | Outdoor PE | 44.5 | 668 | 0.15 | 1,241.5 | 3,267 | 286 A | NR/PS/ELP/00008 19/33kV–25/44kV (1×185 mm²) | |
| 1×240 mm² | Class 1/2 Aluminium | NR/PS/ELP/00008 19/33kV XLPE dielectric | Outdoor PE | 52.5 | 788 | 0.12 | 1,729.0 | 4,550 | 336 A | NR/PS/ELP/00008 19/33kV–25/44kV (1×240 mm²) | |
| 1×300 mm² | Class 1/2 Aluminium | NR/PS/ELP/00008 19/33kV XLPE dielectric | Outdoor PE | 61.4 | 921 | 0.09 | 2,364.4 | 6,222 | 385 A | NR/PS/ELP/00008 19/33kV–25/44kV (1×300 mm²) | |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance & continuity | Within maximum Ω/km limit at 20 °C per IEC 60228 / BS EN 60228 | Every manufactured drum length |
| Dielectric withstand / spark test | No breakdown across insulation, screen or armour | Every manufactured drum length |
| Sample tests | ||
| Vertical flame propagation & jacket qualification | Self-extinguishing and compliant with reference standard limits | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.