SANS 97 / BS 6480 Belted Paper-Insulated Lead-Covered (PILC)SANS 97 / BS 6480 / IEC 60055 · 0.6/1 kV – 6.35/11 kV · -10 °C to +80 °C industrial PILC

SANS 97 / BS 6480 Belted Paper-Insulated Lead-Covered (PILC) Steel-Tape Armoured Power Cable (PILC BELTED) engineered to SANS 97 / BS 6480 / IEC 60055 for 0.6/1 kV – 6.35/11 kV service across -10 °C to +80 °C, featuring stranded copper conductor and pvc outer

Approved
Oil-resistant
Water-resistant
Order designation
PILC BELTED 4G2.5
Outer Ø ≈
10.8 mm
Total weight ≈
186 kg/km
Min. bend R (fixed)
86 mm
Configuration
4 × 2.5 mm²
All sizes (12)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
0.6/1 kV – 6.35/
Per SANS 97 / BS 6480 / IEC 60055
Operating temp.
−10…+80 °C
Continuous thermal rating (SANS 97)
Min. bend radius
15 × OD
Installed / fixed routing
Conductor
copper conductor
High-conductivity copper conductor
Outer layer
PVC outer servin
Extruded PVC outer serving protective
Standard
SANS 97
SANS 97 / BS 6480 / IEC 60055

Typical values for this cable type, based on SANS 97 / BS 6480 / IEC 60055 — confirmed in the datasheet and quotation for your order.

Application fit

Is PILC Belted right for your machine?

SANS 97 / BS 6480 Belted Paper-Insulated Lead-Covered (PILC) Steel-Tape Armoured Power Cable (PILC BELTED) engineered to SANS 97 / BS 6480 / IEC 60055 for 0.6/1 kV – 6.35/11 kV service across -10 °C to +80 °C, featuring stranded copper conductor and pvc outer

Fixed installation

Suitable

Engineered and verified for fixed service in accordance with SANS 97 / BS 6480 / IEC 60055.

Switchgear & control cabinet wiring

Suitable

Suitable for switchgear, control panels and equipment terminations within 15 × OD bend radius.

TBM gantry & advancing tunnel reel

With conditions

Use mechanical conduit or armoured protection where exposed to rock fall or crushing loads.

Motorised monospiral reel

Not suitable

Not designed for high-speed monospiral crane reeling; select a dedicated reeling cable.

NSHTOU Reeling Cable
Typical machinesMining & TunnellingSurface & Underground Mining SubstationsMineral Processing & Smelting PlantsTunnelling & Heavy Civil InfrastructureBulk Material Handling CorridorsRefinery & Petrochemical Process Units

Construction

Layer by layer

Shown: PILC BELTED (SANS 97 / BS 6480 / IEC 60055) with stranded copper conductor, impregnated paper tapes and pvc outer serving (8-layer construction).

12345678
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Stranded copper conductorHigh-conductivity copper conductor per SANS 97 / BS 6480 / IEC 60055SANS 97 / BS 6480 / IEC 60055
2Impregnated paper tapesImpregnated paper tapes (individual core / group layer)SANS 97 / BS 6480 / IEC 60055
3Impregnated paper beltImpregnated paper belt (lapped tape)SANS 97 / BS 6480 / IEC 60055
4Lead alloy sheathExtruded Lead alloy sheath protective layer (continuous layer)SANS 97 / BS 6480 / IEC 60055
5PVC armour beddingPVC armour bedding mechanical protection (continuous layer)SANS 97 / BS 6480 / IEC 60055
6Inner steel armour tapeInner steel armour tape mechanical protection (lapped tape)SANS 97 / BS 6480 / IEC 60055
7Outer steel armour tapeOuter steel armour tape mechanical protection (lapped tape)SANS 97 / BS 6480 / IEC 60055
8PVC outer servingExtruded PVC outer serving protective layer (continuous layer)SANS 97 / BS 6480 / IEC 60055

PILC BELTED — Standard Execution

Built to SANS 97 / BS 6480 / IEC 60055 with stranded copper conductor and pvc outer serving

PILC BELTED — Custom Cross-Sections

Full range of metric mm² and AWG/kcmil conductor sizes per SANS 97 / BS 6480 / IEC 60055

PILC BELTED — Export Drum Supply

Supplied with EN 10204 3.1 routine dielectric & conductor resistance test certificate

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on SANS 97 / BS 6480 / IEC 60055. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / duty
0.6/1 kV – 6.35/11 kV (SANS 97 / BS 6480 / IEC 60055)
Conductor construction
Stranded copper conductor — High-conductivity copper conductor per SANS 97 / BS 6480 / IEC 60055
Primary insulation / dielectric
Impregnated paper tapes — Impregnated paper tapes (individual core / group layer)

Thermal

Continuous operating temperature
−10…+80 °C per SANS 97 / BS 6480 / IEC 60055
Short-circuit / peak thermal limit
+160 °C to +250 °C (5 s adiabatic limit depending on dielectric class)
Minimum installation temperature
−5 °C (thermoplastic) / −25 °C (cross-linked or elastomer) / −40 °C (metallic)

Mechanical

Outer protection / covering
PVC outer serving — Extruded PVC outer serving protective layer (continuous layer)
Minimum bending radius
15 × OD (installed / static routing)
Layer count & geometry
8 concentric/structural layers verified by cross-section inspection

Resistance

Environmental & chemical durability
Engineered for industrial service in accordance with SANS 97 / BS 6480 / IEC 60055
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing product standard
SANS 97 / BS 6480 / IEC 60055
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
PILC BELTED
Customs tariff (HS)
8544.49 / 8544.60 / 7614.10

Sizes

12 standard PILC BELTED cable sizes

Manufactured to SANS 97 / BS 6480 / IEC 60055 across standard single-core and multi-core cross-sections.

Dimensions, construction & weights
Order designationConfigurationOuter Ø ≈
mm
Weight ≈
kg/km
Min. bend R
fixed mm
Enquiry
PILC BELTED Standard Production Schedule (0.6/1 kV – 6.35/11 kV · −10…+80 °C)
PILC BELTED 3G1.53 × 1.5 mm²8.410568
PILC BELTED 4G1.54 × 1.5 mm²9.212874
PILC BELTED 5G1.55 × 1.5 mm²10.115681
PILC BELTED 3G2.53 × 2.5 mm²9.814878
PILC BELTED 4G2.54 × 2.5 mm²10.818686
PILC BELTED 5G2.55 × 2.5 mm²11.922895
PILC BELTED 4G44 × 4.0 mm²12.6268101
PILC BELTED 4G64 × 6.0 mm²14.2365114
PILC BELTED 4G104 × 10 mm²17.5580140
PILC BELTED 4G164 × 16 mm²20.4845163
PILC BELTED 4G254 × 25 mm²24.81,290198
PILC BELTED 4G354 × 35 mm²27.91,710223
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Single-core and multi-core sizes from 0.5 mm² up to 630 mm² (or AWG/kcmil) available per SANS 97 / BS 6480 / IEC 60055.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor DC resistance & dimensional verification (SANS 97 / BS 6480 / IEC 60055)DC resistance at 20 °C and geometry within SANS 97 / BS 6480 / IEC 60055 class limitsEvery manufactured drum / spool
Routine dielectric / spark / structural integrity test (SANS 97 / BS 6480 / IEC 60055)Zero breakdown or structural defect over full production lengthEvery manufactured drum / spool
Sample tests
Thermal aging, mechanical & material qualification (SANS 97 / BS 6480 / IEC 60055)Full compliance with SANS 97 / BS 6480 / IEC 60055 across −10…+80 °CType qualification & periodic sample audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

SANS 97 CompliantEN 10204 3.1 Routine Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX PILC BELTED <size> SANS 97 0.6/1 kV – 6.35/11 kV CE
Delivery form
Non-returnable fumigated wooden drums or precision DIN spools
Standard lengths
500 m · 1000 m · 2000 m drums (custom cut lengths on request)
MOQ
500 m (stock sizes) · 1000 m (custom production)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-21
Updated
2026-10-21

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define PILC BELTED (SANS 97 / BS 6480 Belted Paper-Insulated Lead-Covered (PILC) Steel-Tape Armoured Power Cable)?
PILC BELTED (SANS 97 / BS 6480 Belted Paper-Insulated Lead-Covered (PILC) Steel-Tape Armoured Power Cable) is manufactured in accordance with SANS 97 / BS 6480 / IEC 60055 for 0.6/1 kV – 6.35/11 kV service over -10 °C to +80 °C. Its 8-layer construction comprises stranded copper conductor, impregnated paper tapes, impregnated paper belt, lead alloy sheath, pvc armour bedding, inner steel armour tape, outer steel armour tape, pvc outer serving.
What is the minimum bending radius and installation temperature for PILC BELTED?
The minimum installed bending radius for PILC BELTED is 15 × OD across its continuous operating temperature range of -10 °C to +80 °C, ensuring mechanical and dielectric stability without conductor or insulation strain.
How are the concentric layers of PILC BELTED arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Stranded copper conductor (High-conductivity copper conductor per SANS 97 / BS 6480 / IEC 60055); (02) Impregnated paper tapes (Impregnated paper tapes (individual core / group layer)); (03) Impregnated paper belt (Impregnated paper belt (lapped tape)); (04) Lead alloy sheath (Extruded Lead alloy sheath protective layer (continuous layer)); (05) PVC armour bedding (PVC armour bedding mechanical protection (continuous layer)); (06) Inner steel armour tape (Inner steel armour tape mechanical protection (lapped tape)); (07) Outer steel armour tape (Outer steel armour tape mechanical protection (lapped tape)); (08) PVC outer serving (Extruded PVC outer serving protective layer (continuous layer)).
What factory test certificates are supplied with PILC BELTED?
Every production drum or spool of PILC BELTED undergoes routine conductor DC resistance, dimensional and dielectric/integrity testing per SANS 97 / BS 6480 / IEC 60055, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for PILC Belted

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

PILC Belted SANS 97 / BS 6480 Belted Paper-Insulated Lead-Covered (PILC)

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 