Contact
submarine & offshore power composite cableIEC 60502-2 / IEC 60840 Submarine6 kV – 170 kV (-20 to +90 °C)PP / Jute Protective Outer Serving

6–170 kV AC XLPE/EPR Lead Water-Barrier Steel/Copper-Armoured Submarine Power Transmission CableIEC 60502-2 / IEC 60840 Submarine — 6 kV – 170 kV — -20 to +90 °C Subsea & Offshore Cable

6–170 kV AC XLPE/EPR Lead Water-Barrier Steel/Copper-Armoured Submarine Power Transmission Cable (IEC 60502-2 / IEC 60840 Submarine) engineered for 6 kV – 170 kV service across -20 to +90 °C (min. bend radius 15 × OD).

Water-resistant
EMC screen
Oil-resistant
Approved
Order designation
6–170kV Submarine Power Config A
Outer Ø ≈
32.0 mm
Net weight ≈
1,850 kg/km
Tensile rating ≈
85.0 kN
Core / stranding
Compacted / Class 5 Cu/SnCu + FO
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
6 kV – 170 kV
Tested per IEC 60502-2 / IEC 60840 Subma
Operating temp.
−20…+90 °C
Continuous subsea & offshore service
Min. bend radius
15 × OD
Winch sheave, chute & seabed routing
Core / conductor
6-170 kV XLPE /
Stranded copper/aluminum conductors with
Outer protection
PP / Jute Protec
Abrasion-resistant polypropylene yarn ou
Standard
IEC 60502-2 / IE
IEC 60502-2 & IEC 60840 6–170 kV XLPE/EP

Typical values for this cable type, based on IEC 60502-2 & IEC 60840 6–170 kV XLPE/EPR Lead-Sheathed Submarine Power Specification — confirmed in the datasheet and quotation for your order.

Application fit

Is 6–170kV Submarine Power right for your machine?

6–170 kV AC XLPE/EPR Lead Water-Barrier Steel/Copper-Armoured Submarine Power Transmission Cable (IEC 60502-2 / IEC 60840 Submarine) engineered for 6 kV – 170 kV service across -20 to +90 °C (min. bend radius 15 × OD).

Offshore platform & shipboard deck trays

Suitable

Halogen-free SHF1/SHF2, IEEE 1580 Type P or PE/PP submarine outer serving withstands marine salt mist, drilling mud and seabed/deck duty.

Fixed installation

Suitable

Approved for submarine seabed burial, J-tube pull-in, offshore platform cable ladders and shipboard bulkhead penetrations.

Immersion & wet locations

Suitable

Extruded lead-alloy radial water barrier or cross-linked marine elastomer sheath prevents moisture ingress in subsea and wet-deck service.

Motor stator, traction & converter leads

Suitable

Compacted copper or extra-flexible Class I/K tinned copper conductors terminate cleanly into offshore switchboards, transformers and thrus

Energy chain / drag chain

Not suitable

Submarine and armoured offshore power cable is not designed for high-cycle automation drag chains.

Use Drag-Chain Servo Cable
Typical machinesMarine & Offshore CableOffshore Wind Inter-Array & Export Submarine LinksSubsea Island & Platform HV/MV Power InterconnectsOffshore Oil & Gas Drilling Rigs & FPSOsCommercial Vessels, Polar Ships & Marine Propulsion

Construction

Layer by layer

Shown: 6–170kV Submarine Power (IEC 60502-2 & IEC 60840 6–170 kV XLPE/EPR Lead-Sheathed Submarine Power Specification) featuring 6-170 kv xlpe / epr power cores, lead water-blocking sheath & optical unit and pp / jute protective outer serving (4-layer construction).

1234
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
16-170 kV XLPE / EPR Power CoresStranded copper/aluminum conductors with triple-extruded dielectric
2Lead Water-Blocking Sheath & Optical UniExtruded lead moisture barrier + interstitial fiber-optic unit
3PE Inner Bedding & Steel Wire ArmourPolyethylene inner sheath + galvanized steel wire armour
4PP / Jute Protective Outer ServingAbrasion-resistant polypropylene yarn outer serving

6–170kV Submarine Power — Standard Subsea & Offshore Execution

Built to IEC 60502-2 & IEC 60840 6–170 kV XLPE/EPR Lead-Sheathed Submarine Power Specification with 6-170 kv xlpe / epr power cores and pp / jute protective outer serving

6–170kV Submarine Power — Custom Continuous Winch / Reel Length

Available in custom continuous subsea winch, tow or seabed lengths with water-blocked terminations

6–170kV Submarine Power — Hydrostatic, Tensile & Routine Certified

Supplied with EN 10204 3.1 routine dielectric, optical OTDR / DC resistance & tensile test report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on IEC 60502-2 & IEC 60840 6–170 kV XLPE/EPR Lead-Sheathed Submarine Power Specification. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
6 kV – 170 kV (IEC 60502-2 & IEC 60840 6–170 kV XLPE/EPR Lead-Sheathed Submarine Power Specification)
Core / conductor construction
6-170 kV XLPE / EPR Power Cores — Stranded copper/aluminum conductors with triple-extruded dielectric
Primary dielectric / buffering
Lead Water-Blocking Sheath & Optical Unit — Extruded lead moisture barrier + interstitial fiber-optic unit

Thermal

Continuous operating temperature
−20…+90 °C (subsea & offshore duty)
Hydrostatic & thermal stability
Verified thermal and hydrostatic stability per IEC 60502-2 & IEC 60840 6–170 kV XLPE/EPR Lead-Sheathed Submarine Power Specification
Storage & transport temperature
−40…+80 °C on export wooden/steel winch reel

Mechanical

Outer protection / armouring
PP / Jute Protective Outer Serving — Abrasion-resistant polypropylene yarn outer serving
Minimum bending radius
15 × OD
Armour, strength member & mechanical duty
PE Inner Bedding & Steel Wire Armour — Polyethylene inner sheath + galvanized steel wire armour

Resistance

Seawater, hydrostatic & hydrolysis resistance
Engineered for continuous seawater immersion, pressure cycling and hydrolysis resistance per IEC 60502-2 & IEC 60840 6–170 kV XLPE/EPR Lead-Sheathed Submarine Power Specification
Oil, drilling mud & abrasion resistance
Resistant to marine hydraulic oils, salt mist, winch sheave wear and seabed abrasion per IEC 60502-2 & IEC 60840 6–170 kV XLPE/EPR Lead-Sheathed Submarine Power Specification
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
IEC 60502-2 & IEC 60840 6–170 kV XLPE/EPR Lead-Sheathed Submarine Power Specification
Environmental & test standards
IEC 60228 / IEC 60794 / ITU-T G.972 / IEEE 1580 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
6–170kV Submarine Power
Sheath colour & metre marking
Continuous metre-marked black outer finish (PP / Jute Protec)
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard 6–170kV Submarine Power subsea & offshore configurations

Manufactured to IEC 60502-2 & IEC 60840 6–170 kV XLPE/EPR Lead-Sheathed Submarine Power Specification for subsea, oceanographic, ROV, seismic and offshore applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Breaking / tensile
kN ≈
Min. bend R
mm
Enquiry
6–170kV Submarine Power Construction Schedule (−20…+90 °C)
6–170kV Submarine Power Config A3×25–50 mm² (or 3P+FO Composite)Compacted / Class 5 Cu/SnCu + FO32.01,85085.0380
6–170kV Submarine Power Config B3×95–150 mm² (or Heavy EOM)Compacted / Class 5 Cu/SnCu + FO48.54,280130.0580
6–170kV Submarine Power Config C3×240–400 mm² (or Trunk HV/MV)Compacted Cu + Lead/Armour + FO78.09,650210.0950
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour breaking loads and continuous winch/seabed lengths available per IEC 60502-2 & IEC 60840 6–170 kV XLPE/EPR Lead-Sheathed Submarine Power Specification.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, optical OTDR continuity & dimensional verification (IEC 60502-2 & IEC 60840 6–170 kV XLPE/EPR Lead-Sheathed Submarine Power Specification)DC resistance at 20 °C / optical attenuation and outer diameter within IEC 60502-2 & IEC 60840 6–170 kV XLPE/EPR Lead-Sheathed Submarine Power Specification tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (IEC 60502-2 & IEC 60840 6–170 kV XLPE/EPR Lead-Sheathed Submarine Power Specification)Zero dielectric breakdown and verified insulation resistance for 6 kV – 170 kV ratingEvery manufactured drum length
Sample tests
Hydrostatic pressure, tensile breaking load & water-blocking qualification (IEC 60502-2 & IEC 60840 6–170 kV XLPE/EPR Lead-Sheathed Submarine Power Specification)Verified subsea pressure integrity, torque-balanced tensile performance and thermal stability across −20…+90 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

IEC 60502-2 / IEC 60840 Submarine CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX 6–170kV Submarine Power IEC 60502-2 / IEC 60840 Submarine 6 kV – 170 kV CE
Delivery form
Heavy-duty export fumigated wooden drums, steel oceanographic winch reels or submarine turntables
Standard lengths
500 m, 1,000 m, 3,000 m, 6,000 m or custom continuous subsea lengths
MOQ
100 m (standard configurations) · 500 m (custom subsea builds)
Lead time
2–6 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-26
Updated
2026-10-26

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define 6–170kV Submarine Power (6–170 kV AC XLPE/EPR Lead Water-Barrier Steel/Copper-Armoured Submarine Power Transmission Cable)?
6–170kV Submarine Power (6–170 kV AC XLPE/EPR Lead Water-Barrier Steel/Copper-Armoured Submarine Power Transmission Cable) is manufactured in accordance with IEC 60502-2 & IEC 60840 6–170 kV XLPE/EPR Lead-Sheathed Submarine Power Specification for 6 kV – 170 kV service over -20 to +90 °C. Its 4-layer construction comprises 6-170 kv xlpe / epr power cores, lead water-blocking sheath & optical unit and pp / jute protective outer serving.
What is the minimum bending radius and operating temperature range for 6–170kV Submarine Power?
The minimum bending radius for 6–170kV Submarine Power is 15 × OD across its continuous operating temperature range of -20 to +90 °C, ensuring mechanical, hydrostatic and dielectric reliability in subsea and offshore service.
How are the concentric layers of 6–170kV Submarine Power arranged from inside to outside?
From inside to outside, the construction sequence is: (01) 6-170 kV XLPE / EPR Power Cores — Stranded copper/aluminum conductors with triple-extruded dielectric; (02) Lead Water-Blocking Sheath & Optical Unit — Extruded lead moisture barrier + interstitial fiber-optic unit; (03) PE Inner Bedding & Steel Wire Armour — Polyethylene inner sheath + galvanized steel wire armour; (04) PP / Jute Protective Outer Serving — Abrasion-resistant polypropylene yarn outer serving.
What factory test certificates are supplied with 6–170kV Submarine Power?
Every production drum of 6–170kV Submarine Power undergoes routine conductor resistance/OTDR continuity, high-voltage dielectric and dimensional testing per IEC 60502-2 & IEC 60840 6–170 kV XLPE/EPR Lead-Sheathed Submarine Power Specification, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for 6–170kV Submarine Power

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

6–170 kV AC XLPE/EPR Lead Water-Barrier Steel/Copper-Armoured Submarine Power Transmission Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote