BS 6724 XLPE-SWA-LSZHBS 6724 / IEC 60502-10.6/1 kV – 1.9/3.3 kV−25…+90 °C

BS 6724 0.6/1 kV Cu/XLPE/LSZH/SWA/LSZH Low-Smoke Zero-Halogen CableBS 6724 / IEC 60502-1 · 0.6/1 kV – 1.9/3.3 kV · -25 °C to +90 °C industrial BS 6724

BS 6724 0.6/1 kV Cu/XLPE/LSZH/SWA/LSZH Low-Smoke Zero-Halogen Armoured Cable (BS 6724 XLPE-SWA-LSZH) engineered to BS 6724 / IEC 60502-1 for 0.6/1 kV – 1.9/3.3 kV service across -25 °C to +90 °C, featuring stranded copper conductor and lszh outer sheath with

Approved
Flame-retardant
Oil-resistant
Order designation
BS 6724 XLPE-SWA-LSZH 4G2.5
Outer Ø ≈
10.8 mm
Total weight ≈
186 kg/km
Min. bend R (fixed)
86 mm
Configuration
4 × 2.5 mm²
All sizes (12)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
0.6/1 kV – 1.9/3
Per BS 6724 / IEC 60502-1
Operating temp.
−25…+90 °C
Continuous thermal rating (BS 6724)
Min. bend radius
8 × OD
Installed / fixed routing
Conductor
copper conductor
High-conductivity copper conductor
Outer layer
LSZH outer
Extruded LSZH outer sheath protective
Standard
BS 6724
BS 6724 / IEC 60502-1

Typical values for this cable type, based on BS 6724 / IEC 60502-1 — confirmed in the datasheet and quotation for your order.

Application fit

Is BS 6724 XLPE-SWA-LSZH right for your machine?

BS 6724 0.6/1 kV Cu/XLPE/LSZH/SWA/LSZH Low-Smoke Zero-Halogen Armoured Cable (BS 6724 XLPE-SWA-LSZH) engineered to BS 6724 / IEC 60502-1 for 0.6/1 kV – 1.9/3.3 kV service across -25 °C to +90 °C, featuring stranded copper conductor and lszh outer sheath with

Fixed installation

Suitable

Engineered and verified for fixed service in accordance with BS 6724 / IEC 60502-1.

Switchgear & control cabinet wiring

Suitable

Suitable for switchgear, control panels and equipment terminations within 8 × OD bend radius.

TBM gantry & advancing tunnel reel

With conditions

Use mechanical conduit or armoured protection where exposed to rock fall or crushing loads.

Motorised monospiral reel

Not suitable

Not designed for high-speed monospiral crane reeling; select a dedicated reeling cable.

NSHTOU Reeling Cable
Typical machinesBuilding & Fire SafetyCommercial & Residential Building DistributionData Centers & Public InfrastructureFire-Safe Evacuation & Riser ShaftsIndustrial Plant Balance-of-Plant Wiring25 kV AC & 1.5/3 kV DC Railway Overhead Catenary

Construction

Layer by layer

Shown: BS 6724 XLPE-SWA-LSZH (BS 6724 / IEC 60502-1) with stranded copper conductor, xlpe core insulation and lszh outer sheath (5-layer construction).

12345
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Stranded copper conductorHigh-conductivity copper conductor per BS 6724 / IEC 60502-1BS 6724 / IEC 60502-1
2XLPE core insulationExtruded XLPE dielectric (individual core / group layer)BS 6724 / IEC 60502-1
3Non-hygroscopic beddingExtruded Non-hygroscopic bedding protective layer (continuous layer)BS 6724 / IEC 60502-1
4Galvanized steel wire armourGalvanized steel wire armour mechanical protection (helically applied wires)BS 6724 / IEC 60502-1
5LSZH outer sheathExtruded LSZH outer sheath protective layer (continuous layer)BS 6724 / IEC 60502-1

BS 6724 XLPE-SWA-LSZH — Standard Execution

Built to BS 6724 / IEC 60502-1 with stranded copper conductor and lszh outer sheath

BS 6724 XLPE-SWA-LSZH — Custom Cross-Sections

Full range of metric mm² and AWG/kcmil conductor sizes per BS 6724 / IEC 60502-1

BS 6724 XLPE-SWA-LSZH — Export Drum Supply

Supplied with EN 10204 3.1 routine dielectric & conductor resistance test certificate

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on BS 6724 / IEC 60502-1. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / duty
0.6/1 kV – 1.9/3.3 kV (BS 6724 / IEC 60502-1)
Conductor construction
Stranded copper conductor — High-conductivity copper conductor per BS 6724 / IEC 60502-1
Primary insulation / dielectric
XLPE core insulation — Extruded XLPE dielectric (individual core / group layer)

Thermal

Continuous operating temperature
−25…+90 °C per BS 6724 / IEC 60502-1
Short-circuit / peak thermal limit
+160 °C to +250 °C (5 s adiabatic limit depending on dielectric class)
Minimum installation temperature
−5 °C (thermoplastic) / −25 °C (cross-linked or elastomer) / −40 °C (metallic)

Mechanical

Outer protection / covering
LSZH outer sheath — Extruded LSZH outer sheath protective layer (continuous layer)
Minimum bending radius
8 × OD (installed / static routing)
Layer count & geometry
5 concentric/structural layers verified by cross-section inspection

Resistance

Environmental & chemical durability
Engineered for industrial service in accordance with BS 6724 / IEC 60502-1
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing product standard
BS 6724 / IEC 60502-1
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
BS 6724 XLPE-SWA-LSZH
Customs tariff (HS)
8544.49 / 8544.60 / 7614.10

Sizes

12 standard BS 6724 XLPE-SWA-LSZH cable sizes

Manufactured to BS 6724 / IEC 60502-1 across standard single-core and multi-core cross-sections.

Dimensions, construction & weights
Order designationConfigurationOuter Ø ≈
mm
Weight ≈
kg/km
Min. bend R
fixed mm
Enquiry
BS 6724 XLPE-SWA-LSZH Standard Production Schedule (0.6/1 kV – 1.9/3.3 kV · −25…+90 °C)
BS 6724 XLPE-SWA-LSZH 3G1.53 × 1.5 mm²8.410568
BS 6724 XLPE-SWA-LSZH 4G1.54 × 1.5 mm²9.212874
BS 6724 XLPE-SWA-LSZH 5G1.55 × 1.5 mm²10.115681
BS 6724 XLPE-SWA-LSZH 3G2.53 × 2.5 mm²9.814878
BS 6724 XLPE-SWA-LSZH 4G2.54 × 2.5 mm²10.818686
BS 6724 XLPE-SWA-LSZH 5G2.55 × 2.5 mm²11.922895
BS 6724 XLPE-SWA-LSZH 4G44 × 4.0 mm²12.6268101
BS 6724 XLPE-SWA-LSZH 4G64 × 6.0 mm²14.2365114
BS 6724 XLPE-SWA-LSZH 4G104 × 10 mm²17.5580140
BS 6724 XLPE-SWA-LSZH 4G164 × 16 mm²20.4845163
BS 6724 XLPE-SWA-LSZH 4G254 × 25 mm²24.81,290198
BS 6724 XLPE-SWA-LSZH 4G354 × 35 mm²27.91,710223
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Single-core and multi-core sizes from 0.5 mm² up to 630 mm² (or AWG/kcmil) available per BS 6724 / IEC 60502-1.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor DC resistance & dimensional verification (BS 6724 / IEC 60502-1)DC resistance at 20 °C and geometry within BS 6724 / IEC 60502-1 class limitsEvery manufactured drum / spool
Routine dielectric / spark / structural integrity test (BS 6724 / IEC 60502-1)Zero breakdown or structural defect over full production lengthEvery manufactured drum / spool
Sample tests
Thermal aging, mechanical & material qualification (BS 6724 / IEC 60502-1)Full compliance with BS 6724 / IEC 60502-1 across −25…+90 °CType qualification & periodic sample audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

BS 6724 CompliantEN 10204 3.1 Routine Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX BS 6724 XLPE-SWA-LSZH <size> BS 6724 0.6/1 kV – 1.9/3.3 kV CE
Delivery form
Non-returnable fumigated wooden drums or precision DIN spools
Standard lengths
500 m · 1000 m · 2000 m drums (custom cut lengths on request)
MOQ
500 m (stock sizes) · 1000 m (custom production)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-21
Updated
2026-10-21

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define BS 6724 XLPE-SWA-LSZH (BS 6724 0.6/1 kV Cu/XLPE/LSZH/SWA/LSZH Low-Smoke Zero-Halogen Armoured Cable)?
BS 6724 XLPE-SWA-LSZH (BS 6724 0.6/1 kV Cu/XLPE/LSZH/SWA/LSZH Low-Smoke Zero-Halogen Armoured Cable) is manufactured in accordance with BS 6724 / IEC 60502-1 for 0.6/1 kV – 1.9/3.3 kV service over -25 °C to +90 °C. Its 5-layer construction comprises stranded copper conductor, xlpe core insulation, non-hygroscopic bedding, galvanized steel wire armour, lszh outer sheath.
What is the minimum bending radius and installation temperature for BS 6724 XLPE-SWA-LSZH?
The minimum installed bending radius for BS 6724 XLPE-SWA-LSZH is 8 × OD across its continuous operating temperature range of -25 °C to +90 °C, ensuring mechanical and dielectric stability without conductor or insulation strain.
How are the concentric layers of BS 6724 XLPE-SWA-LSZH arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Stranded copper conductor (High-conductivity copper conductor per BS 6724 / IEC 60502-1); (02) XLPE core insulation (Extruded XLPE dielectric (individual core / group layer)); (03) Non-hygroscopic bedding (Extruded Non-hygroscopic bedding protective layer (continuous layer)); (04) Galvanized steel wire armour (Galvanized steel wire armour mechanical protection (helically applied wires)); (05) LSZH outer sheath (Extruded LSZH outer sheath protective layer (continuous layer)).
What factory test certificates are supplied with BS 6724 XLPE-SWA-LSZH?
Every production drum or spool of BS 6724 XLPE-SWA-LSZH undergoes routine conductor DC resistance, dimensional and dielectric/integrity testing per BS 6724 / IEC 60502-1, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for BS 6724 XLPE-SWA-LSZH

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

BS 6724 0.6/1 kV Cu/XLPE/LSZH/SWA/LSZH Low-Smoke Zero-Halogen Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote