Contact

Flat Tinned Copper Flexible Earthing & Equipotential Bonding BraidBS EN 13602 / DIN 46444 · Equipotential / EMC · -55 °C to +150 °C industrial TCEB 10×2 Tinned

Flat Tinned Copper Flexible Earthing & Equipotential Bonding Braid Strap (TCEB 10×2 Tinned Copper Braid) engineered to BS EN 13602 / DIN 46444 for Equipotential / EMC service across -55 °C to +150 °C, featuring fine-stranded cu-etp copper filaments and flat

Approved
Low-EMC design
EMC screen
Order designation
TCEB 10×2 Tinned Copper Braid 4G2.5
Outer Ø ≈
10.8 mm
Total weight ≈
186 kg/km
Min. bend R (fixed)
86 mm
Configuration
4 × 2.5 mm²
All sizes (12)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
Equipotential
Per BS EN 13602 / DIN 46444
Operating temp.
−55…+150 °C
Continuous thermal rating
Min. bend radius
3 × OD
Installed / fixed routing
Conductor
Fine-stranded
0.15 mm or 0.20 mm annealed
Outer layer
Flat rolled
Multi-carrier interwoven tinned
Standard
BS EN 13602
BS EN 13602 / DIN 46444

Typical values for this cable type, based on BS EN 13602 / DIN 46444 — confirmed in the datasheet and quotation for your order.

Application fit

Is TCEB 10×2 Tinned Copper Braid right for your machine?

Flat Tinned Copper Flexible Earthing & Equipotential Bonding Braid Strap (TCEB 10×2 Tinned Copper Braid) engineered to BS EN 13602 / DIN 46444 for Equipotential / EMC service across -55 °C to +150 °C, featuring fine-stranded cu-etp copper filaments and flat

Switchgear & control cabinet wiring

Suitable

Engineered and verified for cabinet chassis service in accordance with BS EN 13602 / DIN 46444.

Motor stator, traction & converter leads

Suitable

Engineered and verified for motor lead service in accordance with BS EN 13602 / DIN 46444.

Fixed installation

Suitable

Qualified for fixed installation on trays, racks, conduits or supports per BS EN 13602 / DIN 46444.

TBM gantry & advancing tunnel reel

With conditions

Use mechanical conduit or armoured protection where exposed to rock fall or crushing loads.

Typical machinesRailway & TransitAutomated Assembly & Packaging LinesCNC Machine Tools & RoboticsPLC/DCS Control & Marshalling CabinetsIndustrial Drives & Motor Manufacturing25 kV AC & 1.5/3 kV DC Railway Overhead Catenary

Construction

Layer by layer

Shown: TCEB 10×2 Tinned Copper Braid (BS EN 13602 / DIN 46444) with fine-stranded cu-etp copper filaments, flat rolled electro-tinned tubular braid weave and flat rolled electro-tinned tubular braid weave (2-layer construction).

12
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Fine-stranded Cu-ETP copper filaments0.15 mm or 0.20 mm annealed electrolytic copper (Cu-ETP) individual wiresBS EN 13602 / DIN 46444
2Flat rolled electro-tinned tubular braid weaveMulti-carrier interwoven tinned copper braid rolled into a low-inductance flat strapBS EN 13602 / DIN 46444

TCEB 10×2 Tinned Copper Braid — Standard Execution

Built to BS EN 13602 / DIN 46444 with fine-stranded cu-etp copper filaments and flat rolled electro-tinned

TCEB 10×2 Tinned Copper Braid — Custom Cross-Sections

Full range of metric mm² and AWG/kcmil conductor sizes per BS EN 13602 / DIN 46444

TCEB 10×2 Tinned Copper Braid — Export Drum Supply

Supplied with EN 10204 3.1 routine dielectric & conductor resistance test certificate

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on BS EN 13602 / DIN 46444. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / duty
Equipotential / EMC (BS EN 13602 / DIN 46444)
Conductor construction
Fine-stranded Cu-ETP copper filaments — 0.15 mm or 0.20 mm annealed electrolytic copper (Cu-ETP) individual wires
Primary insulation / dielectric
Flat rolled electro-tinned tubular braid weave — Multi-carrier interwoven tinned copper braid rolled into a low-inductance flat strap

Thermal

Continuous operating temperature
−55…+150 °C per BS EN 13602 / DIN 46444
Short-circuit / peak thermal limit
+160 °C to +250 °C (5 s adiabatic limit depending on dielectric class)
Minimum installation temperature
−5 °C (thermoplastic) / −25 °C (cross-linked or elastomer) / −40 °C (metallic)

Mechanical

Outer protection / covering
Flat rolled electro-tinned tubular braid weave — Multi-carrier interwoven tinned copper braid rolled into a low-inductance flat strap
Minimum bending radius
3 × OD (installed / static routing)
Layer count & geometry
2 concentric/structural layers verified by cross-section inspection

Resistance

Environmental & chemical durability
Engineered for industrial service in accordance with BS EN 13602 / DIN 46444
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing product standard
BS EN 13602 / DIN 46444
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
TCEB 10×2 Tinned Copper Braid
Customs tariff (HS)
8544.49 / 8544.60 / 7614.10

Sizes

12 standard TCEB 10×2 Tinned Copper Braid cable sizes

Manufactured to BS EN 13602 / DIN 46444 across standard single-core and multi-core cross-sections.

Dimensions, construction & weights
Order designationConfigurationOuter Ø ≈
mm
Weight ≈
kg/km
Min. bend R
fixed mm
Enquiry
TCEB 10×2 Tinned Copper Braid Standard Production Schedule (Equipotential / EMC · −55…+150 °C)
TCEB 10×2 Tinned Copper Braid 3G1.53 × 1.5 mm²8.410568
TCEB 10×2 Tinned Copper Braid 4G1.54 × 1.5 mm²9.212874
TCEB 10×2 Tinned Copper Braid 5G1.55 × 1.5 mm²10.115681
TCEB 10×2 Tinned Copper Braid 3G2.53 × 2.5 mm²9.814878
TCEB 10×2 Tinned Copper Braid 4G2.54 × 2.5 mm²10.818686
TCEB 10×2 Tinned Copper Braid 5G2.55 × 2.5 mm²11.922895
TCEB 10×2 Tinned Copper Braid 4G44 × 4.0 mm²12.6268101
TCEB 10×2 Tinned Copper Braid 4G64 × 6.0 mm²14.2365114
TCEB 10×2 Tinned Copper Braid 4G104 × 10 mm²17.5580140
TCEB 10×2 Tinned Copper Braid 4G164 × 16 mm²20.4845163
TCEB 10×2 Tinned Copper Braid 4G254 × 25 mm²24.81,290198
TCEB 10×2 Tinned Copper Braid 4G354 × 35 mm²27.91,710223
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Single-core and multi-core sizes from 0.5 mm² up to 630 mm² (or AWG/kcmil) available per BS EN 13602 / DIN 46444.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor DC resistance & dimensional verification (BS EN 13602 / DIN 46444)DC resistance at 20 °C and geometry within BS EN 13602 / DIN 46444 class limitsEvery manufactured drum / spool
Routine dielectric / spark / structural integrity test (BS EN 13602 / DIN 46444)Zero breakdown or structural defect over full production lengthEvery manufactured drum / spool
Sample tests
Thermal aging, mechanical & material qualification (BS EN 13602 / DIN 46444)Full compliance with BS EN 13602 / DIN 46444 across −55…+150 °CType qualification & periodic sample audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

BS EN 13602 CompliantEN 10204 3.1 Routine Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX TCEB 10×2 Tinned Copper Braid <size> BS EN 13602 Equipotential / EMC CE
Delivery form
Non-returnable fumigated wooden drums or precision DIN spools
Standard lengths
500 m · 1000 m · 2000 m drums (custom cut lengths on request)
MOQ
500 m (stock sizes) · 1000 m (custom production)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-21
Updated
2026-10-21

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define TCEB 10×2 Tinned Copper Braid (Flat Tinned Copper Flexible Earthing & Equipotential Bonding Braid Strap)?
TCEB 10×2 Tinned Copper Braid (Flat Tinned Copper Flexible Earthing & Equipotential Bonding Braid Strap) is manufactured in accordance with BS EN 13602 / DIN 46444 for Equipotential / EMC service over -55 °C to +150 °C. Its 2-layer construction comprises fine-stranded cu-etp copper filaments, flat rolled electro-tinned tubular braid weave.
What is the minimum bending radius and installation temperature for TCEB 10×2 Tinned Copper Braid?
The minimum installed bending radius for TCEB 10×2 Tinned Copper Braid is 3 × OD across its continuous operating temperature range of -55 °C to +150 °C, ensuring mechanical and dielectric stability without conductor or insulation strain.
How are the concentric layers of TCEB 10×2 Tinned Copper Braid arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Fine-stranded Cu-ETP copper filaments (0.15 mm or 0.20 mm annealed electrolytic copper (Cu-ETP) individual wires); (02) Flat rolled electro-tinned tubular braid weave (Multi-carrier interwoven tinned copper braid rolled into a low-inductance flat strap).
What factory test certificates are supplied with TCEB 10×2 Tinned Copper Braid?
Every production drum or spool of TCEB 10×2 Tinned Copper Braid undergoes routine conductor DC resistance, dimensional and dielectric/integrity testing per BS EN 13602 / DIN 46444, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for TCEB 10×2 Tinned Copper Braid

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

TCEB 10×2 Tinned Copper Braid Flat Tinned Copper Flexible Earthing & Equipotential Bonding Braid

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote