Mine roadway & tunnel wall hangers
Engineered for underground mine roadways, inclined drifts and coal/hard-rock substation feeders.
Product
CHKCYDY 3.6/6 kV underground mining medium-voltage power cable built to PN-G-91006 with Class 2 copper phase conductors, HEPR insulation, overall concentric copper earth/screen, galvanized steel wire armour and red flame-retardant PVC jacket.
Typical values for this cable type, based on PN-G-91006 / IEC 60502-2 — confirmed in the datasheet and quotation for your order.
Application fit
CHKCYDY 3.6/6 kV underground mining medium-voltage power cable built to PN-G-91006 with Class 2 copper phase conductors, HEPR insulation, overall concentric copper earth/screen, galvanized steel wire armour and red flame-retardant PVC jacket.
Engineered for underground mine roadways, inclined drifts and coal/hard-rock substation feeders.
Galvanized steel wire armour (C) protects against rockfall impact and crushing in mine galleries.
Suitable for cleated vertical shaft runs when supported at standard mining cleat intervals.
Armoured Class 2 feeder cable for fixed roadway routing; use SHD-GC or NTSCGEWOEU for mobile trailing.
ARG7H1ORConstruction
Shown: CHKCYDY (PN-G-91006 / IEC 60502-2) featuring phase conductors (3x50 mm²), hepr insulation & rubber filler and outer sheath (3.6/6 kv red) (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Phase Conductors (3x50 mm²) | Class 2 circular stranded plain annealed copper conductors for underground mining medium-voltage feedersPN-G-91006 / IEC 60502-2 |
| 2 | HEPR Insulation & Rubber Filler | Natural-coloured high-modulus ethylene propylene rubber (HEPR) core insulation with extruded rubber interstitial fillingPN-G-91006 / IEC 60502-2 |
| 3 | Semiconductive Tape & Concentric Cu | Semiconductive binding tape wrapped with an overall concentric screen of bare copper wires and counter-helix copper tapePN-G-91006 / IEC 60502-2 |
| 4 | Separation Sheath & Steel Armour | Extruded PVC inner separation sheath armoured with spirally applied round galvanized steel wires (SWA)PN-G-91006 / IEC 60502-2 |
| 5 | Outer Sheath (3.6/6 kV Red) | Heavy-duty red ST2 flame-retardant polyvinyl chloride (PVC) outer sheath for 3.6/6 kV underground mine galleriesPN-G-91006 / IEC 60502-2 |
Built to PN-G-91006 / IEC 60502-2 with phase conductors (3x50 mm²) and outer sheath (3.6/6 kv red)
Available in custom drum lengths, core counts or factory-terminated assemblies
Supplied with EN 10204 3.1 routine electrical, dielectric & dimensional inspection report
Technical data
Sizes
Manufactured to PN-G-91006 / IEC 60502-2 for heavy-duty industrial and specialty engineering systems.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Weight ≈ kg/km | Tensile load kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| CHKCYDY Construction Schedule (−30…+90 °C) | |||||||
| CHKCYDY 3×35/16 mm² 3.6/6 kV | 3×35 + 16 mm² | Class 2 Cu + concentric Cu + SWA | 41.2 | 3,180 | 45.0 | 500 | |
| CHKCYDY 3×50/16 mm² 3.6/6 kV | 3×50 + 16 mm² | Class 2 Cu + concentric Cu + SWA | 44.5 | 3,790 | 56.0 | 535 | |
| CHKCYDY 3×70/25 mm² 3.6/6 kV | 3×70 + 25 mm² | Class 2 Cu + concentric Cu + SWA | 48.2 | 4,680 | 72.0 | 580 | |
| CHKCYDY 3×95/25 mm² 3.6/6 kV | 3×95 + 25 mm² | Class 2 Cu + concentric Cu + SWA | 52.0 | 5,690 | 90.0 | 625 | |
| CHKCYDY 3×120/35 mm² 3.6/6 kV | 3×120 + 35 mm² | Class 2 Cu + concentric Cu + SWA | 55.6 | 6,740 | 108.0 | 670 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Capacity | Operating temp. |
|---|---|---|---|
| 3×35 + 16 mm² | 0.52 | 3.6/6 kV / 160 A | −30…+90 °C |
| 3×50 + 16 mm² | 0.39 | 3.6/6 kV / 195 A | −30…+90 °C |
| 3×70 + 25 mm² | 0.27 | 3.6/6 kV / 240 A | −30…+90 °C |
| 3×95 + 25 mm² | 0.19 | 3.6/6 kV / 290 A | −30…+90 °C |
| 3×120 + 35 mm² | 0.15 | 3.6/6 kV / 335 A | −30…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance & dimensional verification (PN-G-91006 / IEC 60502-2) | Electrical parameters and outer diameter within PN-G-91006 / IEC 60502-2 tolerances | Every manufactured drum / length |
| High-voltage dielectric & insulation resistance test (PN-G-91006 / IEC 60502-2) | Zero dielectric breakdown and verified insulation resistance over full length | Every manufactured drum / length |
| Sample tests | ||
| Thermal ageing, mechanical flexing & environmental qualification (PN-G-91006 / IEC 60502-2) | Verified structural and dielectric integrity across −30…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.