MV SWA mining power cable3.6/6 kV MiningConcentric Cu + SWAPN-G-91006

CHKCYDY 3.6/6 kV Concentric-Conductor SWA Mining CablePN-G-91006 / IEC 60502-2 · 3.6/6 kV · -30 °C to +90 °C armoured underground mining power cable

CHKCYDY 3.6/6 kV underground mining medium-voltage power cable built to PN-G-91006 with Class 2 copper phase conductors, HEPR insulation, overall concentric copper earth/screen, galvanized steel wire armour and red flame-retardant PVC jacket.

EMC screen
Flame-retardant
Water-resistant
Approved
Order designation
CHKCYDY 3×50/16 mm² 3.6/6 kV
Outer Ø ≈
44.5 mm
Weight ≈
3,790 kg/km
Tensile load ≈
56.0 kN
Core / stranding
Class 2 Cu + concentric Cu + SWA
All sizes (5)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
3.6/6 (7.2) kV
MV underground mining feeders
Operating temp.
−30…+90 °C
Continuous thermal operating range
Min. bend radius
12–15 × OD
Installed / dynamic routing limit
Core / conductor
Class 2 Cu
3×Cu + concentric Cu + SWA
Outer protection
Red ST2 PVC
Flame-retardant mining PVC + SWA
Standard
PN-G-91006
PN-G-91006 / IEC 60502-2

Typical values for this cable type, based on PN-G-91006 / IEC 60502-2 — confirmed in the datasheet and quotation for your order.

Application fit

Is CHKCYDY right for your machine?

CHKCYDY 3.6/6 kV underground mining medium-voltage power cable built to PN-G-91006 with Class 2 copper phase conductors, HEPR insulation, overall concentric copper earth/screen, galvanized steel wire armour and red flame-retardant PVC jacket.

Mine roadway & tunnel wall hangers

Suitable

Engineered for underground mine roadways, inclined drifts and coal/hard-rock substation feeders.

Fixed installation

Suitable

Galvanized steel wire armour (C) protects against rockfall impact and crushing in mine galleries.

Free-hanging vertical run

With conditions

Suitable for cleated vertical shaft runs when supported at standard mining cleat intervals.

Trailing & towing

Not suitable

Armoured Class 2 feeder cable for fixed roadway routing; use SHD-GC or NTSCGEWOEU for mobile trailing.

ARG7H1OR
Typical machinesMining & TunnellingUnderground Hard-Rock & Coal Mining NetworksMine Shaft & Inclined Drift MV Power FeedersTunnelling & Subterranean Excavation InfrastructureMineral Processing & Heavy Pit Substations

Construction

Layer by layer

Shown: CHKCYDY (PN-G-91006 / IEC 60502-2) featuring phase conductors (3x50 mm²), hepr insulation & rubber filler and outer sheath (3.6/6 kv red) (5-layer construction).

12345
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Phase Conductors (3x50 mm²)Class 2 circular stranded plain annealed copper conductors for underground mining medium-voltage feedersPN-G-91006 / IEC 60502-2
2HEPR Insulation & Rubber FillerNatural-coloured high-modulus ethylene propylene rubber (HEPR) core insulation with extruded rubber interstitial fillingPN-G-91006 / IEC 60502-2
3Semiconductive Tape & Concentric CuSemiconductive binding tape wrapped with an overall concentric screen of bare copper wires and counter-helix copper tapePN-G-91006 / IEC 60502-2
4Separation Sheath & Steel ArmourExtruded PVC inner separation sheath armoured with spirally applied round galvanized steel wires (SWA)PN-G-91006 / IEC 60502-2
5Outer Sheath (3.6/6 kV Red)Heavy-duty red ST2 flame-retardant polyvinyl chloride (PVC) outer sheath for 3.6/6 kV underground mine galleriesPN-G-91006 / IEC 60502-2

CHKCYDY — Standard Execution

Built to PN-G-91006 / IEC 60502-2 with phase conductors (3x50 mm²) and outer sheath (3.6/6 kv red)

CHKCYDY — Custom Length & Configuration

Available in custom drum lengths, core counts or factory-terminated assemblies

CHKCYDY — Factory Routine Certified

Supplied with EN 10204 3.1 routine electrical, dielectric & dimensional inspection report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on PN-G-91006 / IEC 60502-2. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
3.6/6 (7.2) kV (PN-G-91006 / IEC 60502-2)
Core / conductor construction
Phase Conductors (3x50 mm²) — Class 2 circular stranded plain annealed copper conductors for underground mining medium-voltage feeders
Primary dielectric / insulation
HEPR Insulation & Rubber Filler — Natural-coloured high-modulus ethylene propylene rubber (HEPR) core insulation with extruded rubber interstitial filling

Thermal

Continuous operating temperature
−30…+90 °C (rated operating envelope)
Storage & transport temperature
−40…+80 °C on export drum or reel

Mechanical

Outer protection / sheath
Outer Sheath (3.6/6 kV Red) — Heavy-duty red ST2 flame-retardant polyvinyl chloride (PVC) outer sheath for 3.6/6 kV underground mine galleries
Minimum bending radius
12–15 × OD
Structural layer count
5 concentric functional layers

Resistance

Environmental & chemical resistance
Industrial moisture, oils and mechanical wear per PN-G-91006 / IEC 60502-2
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
PN-G-91006 / IEC 60502-2
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
CHKCYDY
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

5 standard CHKCYDY configurations

Manufactured to PN-G-91006 / IEC 60502-2 for heavy-duty industrial and specialty engineering systems.

Dimensions, tensile ratings & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Weight ≈
kg/km
Tensile load
kN ≈
Min. bend R
mm
Enquiry
CHKCYDY Construction Schedule (−30…+90 °C)
CHKCYDY 3×35/16 mm² 3.6/6 kV3×35 + 16 mm²Class 2 Cu + concentric Cu + SWA41.23,18045.0500
CHKCYDY 3×50/16 mm² 3.6/6 kV3×50 + 16 mm²Class 2 Cu + concentric Cu + SWA44.53,79056.0535
CHKCYDY 3×70/25 mm² 3.6/6 kV3×70 + 25 mm²Class 2 Cu + concentric Cu + SWA48.24,68072.0580
CHKCYDY 3×95/25 mm² 3.6/6 kV3×95 + 25 mm²Class 2 Cu + concentric Cu + SWA52.05,69090.0625
CHKCYDY 3×120/35 mm² 3.6/6 kV3×120 + 35 mm²Class 2 Cu + concentric Cu + SWA55.66,740108.0670
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core counts, cross-sections, sheath colours and factory-tested cut lengths available per PN-G-91006 / IEC 60502-2.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance & dimensional verification (PN-G-91006 / IEC 60502-2)Electrical parameters and outer diameter within PN-G-91006 / IEC 60502-2 tolerancesEvery manufactured drum / length
High-voltage dielectric & insulation resistance test (PN-G-91006 / IEC 60502-2)Zero dielectric breakdown and verified insulation resistance over full lengthEvery manufactured drum / length
Sample tests
Thermal ageing, mechanical flexing & environmental qualification (PN-G-91006 / IEC 60502-2)Verified structural and dielectric integrity across −30…+90 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

PN-G-91006 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX CHKCYDY PN-G-91006 3.6/6 (7.2) kV CE
Delivery form
Heavy-duty export wooden/steel drums or factory-tested coils
Standard lengths
100 m, 250 m, 500 m, 1,000 m or custom cut-to-length reels
MOQ
100 m (standard configurations) · 300 m (custom builds)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-23
Updated
2026-10-23

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What applications is CHKCYDY engineered for?
CHKCYDY 3.6/6 kV underground mining medium-voltage power cable built to PN-G-91006 with Class 2 copper phase conductors, HEPR insulation, overall concentric copper earth/screen, galvanized steel wire armour and red flame-retardant PVC jacket. It is built to PN-G-91006 / IEC 60502-2 for underground hard-rock & coal mining networks and mine shaft & inclined drift mv power feeders.
What are the minimum bending radius and operating temperature range for CHKCYDY?
The minimum bending radius for CHKCYDY is 12–15 × OD across its continuous operating temperature range of -30 °C to +90 °C, ensuring mechanical and dielectric stability in industrial service.
How are the concentric layers of CHKCYDY arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Phase Conductors (3x50 mm²) (Class 2 circular stranded plain annealed copper conductors for underground mining medium-voltage feeders); (02) HEPR Insulation & Rubber Filler (Natural-coloured high-modulus ethylene propylene rubber (HEPR) core insulation with extruded rubber interstitial filling); (03) Semiconductive Tape & Concentric Cu (Semiconductive binding tape wrapped with an overall concentric screen of bare copper wires and counter-helix copper tape); (04) Separation Sheath & Steel Armour (Extruded PVC inner separation sheath armoured with spirally applied round galvanized steel wires (SWA)); (05) Outer Sheath (3.6/6 kV Red) (Heavy-duty red ST2 flame-retardant polyvinyl chloride (PVC) outer sheath for 3.6/6 kV underground mine galleries).
What factory test certificates are supplied with CHKCYDY?
Every production drum of CHKCYDY undergoes routine electrical continuity, high-voltage dielectric and dimensional testing per PN-G-91006 / IEC 60502-2, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for CHKCYDY

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

CHKCYDY 3.6/6 kV Concentric-Conductor SWA Mining Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote