Double-copper-braid shielded submarine & ship inboard cableIEC 60332-3 Flame Retardant0.6/1 kV Double Cu BraidSubmarine Inboard EMC

REF 57517 & REF 57525 0.6/1 kV Double-Braided Submarine Inboard CableIEC 60332-3 / 60092 · 0.6/1 kV · Double-copper-braid shielded submarine & ship inboard

REF 57517 (0.6/1 kV 4×25 mm² Double-Tinned-Copper-Braid Shielded XLPE Submarine Power Cable) & REF 57525 (Pair-Braided & Overall-Braided LSZH Submarine Instrumentation Cable) (IEC 60332-3 / 60092, 0.6/1 kV, -30 °C to +90 °C).

EMC screen
Low-EMC design
Flame-retardant
Approved
Order designation
REF 57517 Config A (Compact)
Outer Ø ≈
10.4 mm
Net weight ≈
155 kg/km
Tensile rating ≈
4.5 kN
Core / stranding
Stranded tinned Cu (IEC 60228 / ASTM)
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
0.6/1 kV
Tested per IEC 60332-3 / 60092
Operating temp.
−30…+90 °C
Continuous subsea & marine service
Min. bend radius
8 × OD
Dynamic sheave & fixed routing
Core / conductor
4×25 mm²
Flexible Cu power cores or pair-braided
Outer protection
IEC 60332-3 XLPE
Double SnCu EMC braid
Standard
IEC 60332-3
IEC 60092-350

Typical values for this cable type, based on IEC 60092-350 / IEC 60332-3 Bunched Flame-Retardant Naval — confirmed in the datasheet and quotation for your order.

Application fit

Is REF 57517 & REF 57525 right for your machine?

REF 57517 (0.6/1 kV 4×25 mm² Double-Tinned-Copper-Braid Shielded XLPE Submarine Power Cable) & REF 57525 (Pair-Braided & Overall-Braided LSZH Submarine Instrumentation Cable) (IEC 60332-3 / 60092, 0.6/1 kV, -30 °C to +90 °C).

Immersion & wet locations

Suitable

Longitudinally and radially water-blocked construction resists hydrostatic pressure and marine immersion.

Offshore platform & shipboard deck trays

Suitable

Marine-grade jacket resists oil, seawater, UV weathering and mechanical impact on vessels and offshore structures.

Fixed installation

Suitable

Approved for fixed shipboard, submarine outboard, nuclear pool and seabed feeder routing.

Motor stator, traction & converter leads

Suitable

Flexible stranded copper conductors terminate cleanly into submersible pumps, anodes, thrusters and switchgear.

Typical machinesMarine & Offshore CableNaval Shipboard & Submarine OutboardOffshore Cathodic Protection (ICCP)Underwater Welding & Nuclear PoolsDeep-Well & Seabed Pump Feeders

Construction

Layer by layer

Shown: REF 57517 & REF 57525 (IEC 60092-350 / IEC 60332-3 Bunched Flame-Retardant Naval) featuring flexible conductors (4×25 / 2×2×0.75 mm²), 600/1,000 v xlpe core insulation and iec 60332-3 fire-retardant outer sheath (4-layer construction).

1234
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Flexible Conductors (4×25 / 2×2×0.75 mm²)4×25 mm² flexible plain Cu (REF 57517) or 2×2×0.75 mm² tinned Cu pairs (REF 57525)
2600/1,000 V XLPE Core InsulationCross-linked polyethylene insulation (–25 °C to +90 °C operating temperature)
3Double Tinned Copper Braid (0.56 mΩ/m)Two overall tinned Cu braids on REF 57517 (individual pair braid+sheath + overall braid on 57525)
4IEC 60332-3 Fire-Retardant Outer SheathBlack fire-retardant XLPE (REF 57517, Ø 27.8 mm) or LSZH polyolefin (REF 57525, Ø 17.1 mm)

REF 57517 & REF 57525 — Standard Subsea & Marine Execution

Built to IEC 60092-350 / IEC 60332-3 Bunched Flame-Retardant Naval with flexible conductors (4×25 / 2×2×0.75 mm²) and iec 60332-3 fire-retardant outer sheath

REF 57517 & REF 57525 — Custom Drum Length & Termination Kit

Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies

REF 57517 & REF 57525 — Routine & Hydrostatic Test Certified

Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on IEC 60092-350 / IEC 60332-3 Bunched Flame-Retardant Naval. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
0.6/1 kV (IEC 60092-350 / IEC 60332-3 Bunched Flame-Retardant Naval)
Core / conductor construction
Flexible Conductors (4×25 / 2×2×0.75 mm²) — 4×25 mm² flexible plain Cu (REF 57517) or 2×2×0.75 mm² tinned Cu pairs (REF 57525)
Primary dielectric / buffering
600/1,000 V XLPE Core Insulation — Cross-linked polyethylene insulation (–25 °C to +90 °C operating temperature)

Thermal

Continuous operating temperature
−30…+90 °C (subsea, marine & submersible duty)
Short-circuit / peak thermal rating
Verified thermal stability per IEC 60092-350 / IEC 60332-3 Bunched Flame-Retardant Naval
Storage & transport temperature
−40…+80 °C on export wooden/steel drum

Mechanical

Outer protection / armouring
IEC 60332-3 Fire-Retardant Outer Sheath — Black fire-retardant XLPE (REF 57517, Ø 27.8 mm) or LSZH polyolefin (REF 57525, Ø 17.1 mm)
Minimum bending radius
8 × OD
Hydrostatic, tensile & crush duty
Double Tinned Copper Braid (0.56 mΩ/m) — Two overall tinned Cu braids on REF 57517 (individual pair braid+sheath + overall braid on 57525)

Resistance

Hydrostatic pressure & water blocking
Engineered for continuous submersion and hydrostatic integrity per IEC 60092-350 / IEC 60332-3 Bunched Flame-Retardant Naval
Seawater, oil & chemical resistance
Resistant to seawater hydrolysis, hydraulic oils and abrasion per IEC 60092-350 / IEC 60332-3 Bunched Flame-Retardant Naval
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
IEC 60092-350 / IEC 60332-3 Bunched Flame-Retardant Naval
Environmental & test standards
IEC 60228 / IEC 60332 / ISO 13628-5 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
REF 57517 & REF 57525
Sheath colour & metre marking
Continuous metre-marked black outer finish (IEC 60332-3 XLPE / LSZH)
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard REF 57517 & REF 57525 subsea & marine configurations

Manufactured to IEC 60092-350 / IEC 60332-3 Bunched Flame-Retardant Naval for subsea, offshore, deep-well and marine applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Tensile rating
kN ≈
Min. bend R
mm
Enquiry
REF 57517 & REF 57525 Construction Schedule (−30…+90 °C)
REF 57517 Config A (Compact)4×2×24 AWG + 2×18 AWG (or 4C)Stranded tinned Cu (IEC 60228 / ASTM)10.41554.585
REF 57517 Config B (Standard)4×2×20 AWG + 4×16 AWG (or 8C)Stranded tinned Cu (IEC 60228 / ASTM)13.32659.6110
REF 57517 Config C (Heavy Hybrid)8×2×20 AWG + 4×12 AWG (or 12C)Stranded tinned Cu (IEC 60228 / ASTM)16.642018.5140
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour grades and factory drum lengths available per IEC 60092-350 / IEC 60332-3 Bunched Flame-Retardant Naval.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, continuity & dimensional verification (IEC 60092-350 / IEC 60332-3 Bunched Flame-Retardant Naval)DC resistance at 20 °C / optical attenuation and outer diameter within IEC 60092-350 / IEC 60332-3 Bunched Flame-Retardant Naval tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (IEC 60092-350 / IEC 60332-3 Bunched Flame-Retardant Naval)Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV ratingEvery manufactured drum length
Sample tests
Hydrostatic pressure, water-blocking & mechanical endurance qualification (IEC 60092-350 / IEC 60332-3 Bunched Flame-Retardant Naval)Verified submersion integrity, tensile load and thermal stability across −30…+90 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

IEC 60332-3 / 60092 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX REF 57517 & REF 57525 IEC 60332-3 / 60092 0.6/1 kV CE
Delivery form
Heavy-duty export fumigated wooden drums or steel subsea reels
Standard lengths
500 m, 1,000 m or custom continuous subsea/wellbore lengths
MOQ
100 m (standard configurations) · 500 m (custom builds)
Lead time
2–5 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-25
Updated
2026-10-25

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define REF 57517 & REF 57525 (REF 57517 & REF 57525 0.6/1 kV Double-Braided Submarine Inboard Cable)?
REF 57517 & REF 57525 (REF 57517 & REF 57525 0.6/1 kV Double-Braided Submarine Inboard Cable) is manufactured in accordance with IEC 60092-350 / IEC 60332-3 Bunched Flame-Retardant Naval for 0.6/1 kV service over -30 °C to +90 °C. Its 4-layer construction comprises flexible conductors (4×25 / 2×2×0.75 mm²), 600/1,000 v xlpe core insulation and iec 60332-3 fire-retardant outer sheath.
What is the minimum bending radius and operating temperature range for REF 57517 & REF 57525?
The minimum bending radius for REF 57517 & REF 57525 is 8 × OD across its continuous operating temperature range of -30 °C to +90 °C, ensuring mechanical and dielectric reliability in subsea, marine and submersible service.
How are the concentric layers of REF 57517 & REF 57525 arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Flexible Conductors (4×25 / 2×2×0.75 mm²) — 4×25 mm² flexible plain Cu (REF 57517) or 2×2×0.75 mm² tinned Cu pairs (REF 57525); (02) 600/1,000 V XLPE Core Insulation — Cross-linked polyethylene insulation (–25 °C to +90 °C operating temperature); (03) Double Tinned Copper Braid (0.56 mΩ/m) — Two overall tinned Cu braids on REF 57517 (individual pair braid+sheath + overall braid on 57525); (04) IEC 60332-3 Fire-Retardant Outer Sheath — Black fire-retardant XLPE (REF 57517, Ø 27.8 mm) or LSZH polyolefin (REF 57525, Ø 17.1 mm).
What factory test certificates are supplied with REF 57517 & REF 57525?
Every production drum of REF 57517 & REF 57525 undergoes routine conductor resistance/continuity, high-voltage dielectric and dimensional testing per IEC 60092-350 / IEC 60332-3 Bunched Flame-Retardant Naval, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for REF 57517 & REF 57525

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

REF 57517 & REF 57525 0.6/1 kV Double-Braided Submarine Inboard Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 