Immersion & wet locations
Longitudinally and radially water-blocked construction resists hydrostatic pressure and marine immersion.
Product
REF 57517 (0.6/1 kV 4×25 mm² Double-Tinned-Copper-Braid Shielded XLPE Submarine Power Cable) & REF 57525 (Pair-Braided & Overall-Braided LSZH Submarine Instrumentation Cable) (IEC 60332-3 / 60092, 0.6/1 kV, -30 °C to +90 °C).
Typical values for this cable type, based on IEC 60092-350 / IEC 60332-3 Bunched Flame-Retardant Naval — confirmed in the datasheet and quotation for your order.
Application fit
REF 57517 (0.6/1 kV 4×25 mm² Double-Tinned-Copper-Braid Shielded XLPE Submarine Power Cable) & REF 57525 (Pair-Braided & Overall-Braided LSZH Submarine Instrumentation Cable) (IEC 60332-3 / 60092, 0.6/1 kV, -30 °C to +90 °C).
Longitudinally and radially water-blocked construction resists hydrostatic pressure and marine immersion.
Marine-grade jacket resists oil, seawater, UV weathering and mechanical impact on vessels and offshore structures.
Approved for fixed shipboard, submarine outboard, nuclear pool and seabed feeder routing.
Flexible stranded copper conductors terminate cleanly into submersible pumps, anodes, thrusters and switchgear.
Outboard marine and feeder construction is not designed for high-speed crane festoon trolleys.
Use (N)3GRDC5G-J/O Festoon CableConstruction
Shown: REF 57517 & REF 57525 (IEC 60092-350 / IEC 60332-3 Bunched Flame-Retardant Naval) featuring flexible conductors (4×25 / 2×2×0.75 mm²), 600/1,000 v xlpe core insulation and iec 60332-3 fire-retardant outer sheath (4-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Flexible Conductors (4×25 / 2×2×0.75 mm²) | 4×25 mm² flexible plain Cu (REF 57517) or 2×2×0.75 mm² tinned Cu pairs (REF 57525) |
| 2 | 600/1,000 V XLPE Core Insulation | Cross-linked polyethylene insulation (–25 °C to +90 °C operating temperature) |
| 3 | Double Tinned Copper Braid (0.56 mΩ/m) | Two overall tinned Cu braids on REF 57517 (individual pair braid+sheath + overall braid on 57525) |
| 4 | IEC 60332-3 Fire-Retardant Outer Sheath | Black fire-retardant XLPE (REF 57517, Ø 27.8 mm) or LSZH polyolefin (REF 57525, Ø 17.1 mm) |
Built to IEC 60092-350 / IEC 60332-3 Bunched Flame-Retardant Naval with flexible conductors (4×25 / 2×2×0.75 mm²) and iec 60332-3 fire-retardant outer sheath
Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report
Technical data
Sizes
Manufactured to IEC 60092-350 / IEC 60332-3 Bunched Flame-Retardant Naval for subsea, offshore, deep-well and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| REF 57517 & REF 57525 Construction Schedule (−30…+90 °C) | |||||||
| REF 57517 Config A (Compact) | 4×2×24 AWG + 2×18 AWG (or 4C) | Stranded tinned Cu (IEC 60228 / ASTM) | 10.4 | 155 | 4.5 | 85 | |
| REF 57517 Config B (Standard) | 4×2×20 AWG + 4×16 AWG (or 8C) | Stranded tinned Cu (IEC 60228 / ASTM) | 13.3 | 265 | 9.6 | 110 | |
| REF 57517 Config C (Heavy Hybrid) | 8×2×20 AWG + 4×12 AWG (or 12C) | Stranded tinned Cu (IEC 60228 / ASTM) | 16.6 | 420 | 18.5 | 140 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4×2×24 AWG + 2×18 AWG (or 4C) | 28.40 | 0.6/1 kV (45–100 Ω data) | −30…+90 °C |
| 4×2×20 AWG + 4×16 AWG (or 8C) | 10.70 | 0.6/1 kV (45–100 Ω data) | −30…+90 °C |
| 8×2×20 AWG + 4×12 AWG (or 12C) | 5.40 | 0.6/1 kV (High-Power Hybrid) | −30…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (IEC 60092-350 / IEC 60332-3 Bunched Flame-Retardant Naval) | DC resistance at 20 °C / optical attenuation and outer diameter within IEC 60092-350 / IEC 60332-3 Bunched Flame-Retardant Naval tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (IEC 60092-350 / IEC 60332-3 Bunched Flame-Retardant Naval) | Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, water-blocking & mechanical endurance qualification (IEC 60092-350 / IEC 60332-3 Bunched Flame-Retardant Naval) | Verified submersion integrity, tensile load and thermal stability across −30…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.