Contact
submarine aquaculture, shore power & shipboard power cableIEC 60092-353 / IEC 60332-30.6/1 kV (-40 to +90 °C)Subsea / Marine Outer Protective She

Marine YZp 0.6/1kV LSHF Marine Power CableIEC 60092-353 / IEC 60332-3 — 0.6/1 kV — -40 to +90 °C Subsea & Marine Cable

Marine YZp 0.6/1kV LSHF Marine Power Cable featuring flexible stranded copper conductors (7 cores) and subsea / marine outer protective sheath (IEC 60092-353 / IEC 60332-3, 0.6/1 kV, -40 to +90 °C, min. bend radius 4 × OD).

Water-resistant
Flame-retardant
Outdoor & humid
Approved
Order designation
Marine YZp 0.6 4G1.5 / 5C18AWG
Outer Ø ≈
9.6 mm
Net weight ≈
145 kg/km
Max. pulling ≈
2.2 kN
Core / stranding
IEC 60228 Class 5/6 Cu/SnCu
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
0.6/1 kV
Tested per IEC 60092-353 / IEC 60332-3
Operating temp.
−40…+90 °C
Subsea, deck & cold-water duty
Min. bend radius
4 × OD
Winch sheave, TMS & subsea routing
Core / conductor
Flexible Strande
Class 5/ class 6 copper conductors
Outer protection
Subsea / Marine
Black low-smoke zero-halogen (SHF1 / SHF
Standard
IEC 60092-353 /
IEC 60092-353 & IEC 60332-3-22 Marine YZ

Typical values for this cable type, based on IEC 60092-353 & IEC 60332-3-22 Marine YZp 0.6/1 kV LSHF Power Standard — confirmed in the datasheet and quotation for your order.

Application fit

Is Marine YZp 0.6/1kV LSHF right for your machine?

Marine YZp 0.6/1kV LSHF Marine Power Cable featuring flexible stranded copper conductors (7 cores) and subsea / marine outer protective sheath (IEC 60092-353 / IEC 60332-3, 0.6/1 kV, -40 to +90 °C, min. bend radius 4 × OD).

Immersion & wet locations

Suitable

Submarine armoured PE/PP builds and AD8 submersible jackets withstand seabed burial, wave catenaries and continuous seawater immersion.

Fixed installation

Suitable

IEC 60502-1/-2 and IEC 60092-353 constructions install across shore landings, inter-cage subsea grids and shipboard cable trays.

Offshore platform & shipboard deck trays

Suitable

Resistant to seawater, diesel oil, UV weathering and mechanical impact on floating aquaculture collars and port quaysides.

Free-hanging vertical run

Suitable

Dynamic aquaculture catenary and flexible shore-power builds absorb tidal rise, vessel heave and pontoon motion.

Energy chain / drag chain

Not suitable

Submarine armoured feeders and shipboard power cables are not designed for high-cycle automated drag chains.

Use FD 855 P Drag-Chain Cable
Typical machinesUnderwater & Ocean ExplorationSubmarine Electro-Optical Marine Ranch & Island GridsNEK 400-8-820 / NS 9415 Floating Fish Farm Power DistributionAquaculture Workboats, Live-Fish Carriers & Offshore VesselsPort Marina & Fishing Harbour Shore Power Connections

Construction

Layer by layer

Shown: Marine YZp 0.6/1kV LSHF (IEC 60092-353 & IEC 60332-3-22 Marine YZp 0.6/1 kV LSHF Power Standard) featuring flexible stranded copper conductors (7 cores), cross-linked elastomeric / polymer core insulation and subsea / marine outer protective sheath (4-layer construction).

Marine YZp 0.6/1kV LSHF — stepped horizontal cutaway showing Flexible Stranded Copper Conductors (7 Cores) and Subsea
Layer cutaway
#LayerMaterial & reference
1Flexible Stranded Copper Conductors (7 CClass 5/ class 6 copper conductors
2Cross-Linked Elastomeric / Polymer Core Cross-linked polyethylene (xlpe) insulation
3Water-Blocking Tape & Inner BeddingHydrostatic water-blocking filler and low-friction separator wrap
4Subsea / Marine Outer Protective SheathBlack low-smoke zero-halogen (SHF1 / SHF2 / LSZH) flame-retardant outer sheath

Marine YZp 0.6/1kV LSHF — Standard Subsea & Marine Execution

Built to IEC 60092-353 & IEC 60332-3-22 Marine YZp 0.6/1 kV LSHF Power Standard with flexible stranded copper conductors (7 cores) and subsea / marine outer protective sheath

Marine YZp 0.6/1kV LSHF — Custom Winch Length / Molded Termination

Available on continuous export winch drums or factory-terminated with subsea wet-mate / mechanical sockets

Marine YZp 0.6/1kV LSHF — Hydrostatic & Routine Certified

Supplied with EN 10204 3.1 routine dielectric, conductor/optical continuity & hydrostatic qualification report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on IEC 60092-353 & IEC 60332-3-22 Marine YZp 0.6/1 kV LSHF Power Standard. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / operating system
0.6/1 kV (IEC 60092-353 & IEC 60332-3-22 Marine YZp 0.6/1 kV LSHF Power Standard)
Core / conductor construction
Flexible Stranded Copper Conductors (7 Cores) — Class 5/ class 6 copper conductors
Primary dielectric / optical buffer
Cross-Linked Elastomeric / Polymer Core Insulation — Cross-linked polyethylene (xlpe) insulation

Thermal

Continuous operating temperature
−40…+90 °C (submerged seawater & topside deck service)
Hydrostatic & thermal cycling endurance
Verified cold-bend and wet dielectric stability across −40…+90 °C per IEC 60092-353 & IEC 60332-3-22 Marine YZp 0.6/1 kV LSHF Power Standard
Storage & transport temperature
−40…+80 °C on export wooden/steel cable drum

Mechanical

Outer jacket / sheath protection
Subsea / Marine Outer Protective Sheath — Black low-smoke zero-halogen (SHF1 / SHF2 / LSZH) flame-retardant outer sheath
Minimum bending radius
4 × OD
Reinforcement / screen / bedding layer
Water-Blocking Tape & Inner Bedding — Hydrostatic water-blocking filler and low-friction separator wrap

Resistance

Seawater, hydrolysis & oil resistance
Resistant to permanent seawater immersion, hydrolysis, hydraulic oil and bio-fouling per IEC 60092-353 & IEC 60332-3-22 Marine YZp 0.6/1 kV LSHF Power Standard
Hydrostatic pressure & water blocking
Radial and longitudinal water-blocking integrity verified per IEC 60092-353 & IEC 60332-3-22 Marine YZp 0.6/1 kV LSHF Power Standard
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
IEC 60092-353 & IEC 60332-3-22 Marine YZp 0.6/1 kV LSHF Power Standard
Subsea & conductor qualification standards
IEC 60228 / DNV-ST-E402 / ISO 13628-5 / IEC 60794 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
Marine YZp 0.6/1kV LSHF
Sheath colour & metre marking
Continuous metre-marked black outer finish (Subsea / Marine )
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard Marine YZp 0.6/1kV LSHF configurations

Manufactured to IEC 60092-353 & IEC 60332-3-22 Marine YZp 0.6/1 kV LSHF Power Standard for subsea robotics, ROV umbilicals, marine aquaculture and offshore sensor applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Max. pulling
kN ≈
Min. bend R
mm
Enquiry
Marine YZp 0.6/1kV LSHF Construction Schedule (−40…+90 °C)
Marine YZp 0.6 4G1.5 / 5C18AWG4G1.5 mm² (or 5C × 18 AWG)IEC 60228 Class 5/6 Cu/SnCu9.61452.255
Marine YZp 0.6 7G1.5 / 8C16AWG7G1.5 mm² (or 8C × 16 AWG)IEC 60228 Class 5/6 Cu/SnCu12.22353.670
Marine YZp 0.6 12G2.5 / 16C16AWG12G2.5 mm² (or 16C × 16 AWG)IEC 60228 Class 5/6 Cu/SnCu17.45107.5105
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core counts, optical fiber channels, wet-mate terminations and continuous winch lengths available per IEC 60092-353 & IEC 60332-3-22 Marine YZp 0.6/1 kV LSHF Power Standard.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor DC resistance / OTDR optical & dimensional check (IEC 60092-353 & IEC 60332-3-22 Marine YZp 0.6/1 kV LSHF Power Standard)DC resistance at 20 °C, optical attenuation and wall thickness within IEC 60092-353 & IEC 60332-3-22 Marine YZp 0.6/1 kV LSHF Power Standard limitsEvery manufactured drum length
AC high-voltage dielectric & insulation resistance test (IEC 60092-353 & IEC 60332-3-22 Marine YZp 0.6/1 kV LSHF Power Standard)Zero dielectric breakdown and verified wet insulation resistance for 0.6/1 kV ratingEvery manufactured drum length
Sample tests
Hydrostatic pressure, tensile load & seawater immersion qualification (IEC 60092-353 & IEC 60332-3-22 Marine YZp 0.6/1 kV LSHF Power Standard)Verified hydrostatic pressure integrity, breaking load and flex endurance across −40…+90 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

IEC 60092-353 / IEC 60332-3 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX Marine YZp 0.6/1kV LSHF IEC 60092-353 / IEC 60332-3 0.6/1 kV CE
Delivery form
Heavy-duty export fumigated wooden drums, steel winch reels or pre-terminated subsea assemblies
Standard lengths
500 m, 1,000 m, 3,000 m continuous winch lengths or custom cut-to-length subsea jumpers
MOQ
100 m (standard configurations) · 300 m (custom subsea builds)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-29
Updated
2026-10-29

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define Marine YZp 0.6/1kV LSHF (Marine YZp 0.6/1kV LSHF Marine Power Cable)?
Marine YZp 0.6/1kV LSHF (Marine YZp 0.6/1kV LSHF Marine Power Cable) is manufactured in accordance with IEC 60092-353 & IEC 60332-3-22 Marine YZp 0.6/1 kV LSHF Power Standard for 0.6/1 kV subsea,ROV and marine aquaculture service over -40 to +90 °C. Its 4-layer construction comprises flexible stranded copper conductors (7 cores), cross-linked elastomeric / polymer core insulation and subsea / marine outer protective sheath.
What is the minimum bending radius and operating temperature range for Marine YZp 0.6/1kV LSHF?
The minimum bending radius for Marine YZp 0.6/1kV LSHF is 4 × OD across its continuous operating temperature range of -40 to +90 °C, ensuring mechanical flex endurance and hydrostatic reliability in subsea winches, TMS cages and aquaculture installations.
How are the concentric layers of Marine YZp 0.6/1kV LSHF arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Flexible Stranded Copper Conductors (7 Cores) — Class 5/ class 6 copper conductors; (02) Cross-Linked Elastomeric / Polymer Core Insulation — Cross-linked polyethylene (xlpe) insulation; (03) Water-Blocking Tape & Inner Bedding — Hydrostatic water-blocking filler and low-friction separator wrap; (04) Subsea / Marine Outer Protective Sheath — Black low-smoke zero-halogen (SHF1 / SHF2 / LSZH) flame-retardant outer sheath.
What factory test certificates are supplied with Marine YZp 0.6/1kV LSHF?
Every production drum of Marine YZp 0.6/1kV LSHF undergoes routine conductor DC resistance / optical OTDR continuity, AC high-voltage dielectric and dimensional testing per IEC 60092-353 & IEC 60332-3-22 Marine YZp 0.6/1 kV LSHF Power Standard, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for Marine YZp 0.6/1kV LSHF

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

Marine YZp 0.6/1kV LSHF Marine Power Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote