Offshore platform & shipboard deck trays
Halogen-free SHF1/SHF2 or mud-resistant thermoset jacket withstands marine salt mist, oil and deck weathering.
Product
EBS2S & MBS2S 3.8/6.6–19/33 kV BS 6883/7917 UKOOA Offshore Medium-Voltage Power Cable (BS 6883 / BS 7917) engineered for 3.8/6.6 kV – 19/33 kV service across -40 to +90 °C (min. bend radius 12 × OD).
Typical values for this cable type, based on BS 6883 & BS 7917 / UKOOA Code EBS2S & MBS2S (1.9/3.3 kV to 19/33 kV) — confirmed in the datasheet and quotation for your order.
Application fit
EBS2S & MBS2S 3.8/6.6–19/33 kV BS 6883/7917 UKOOA Offshore Medium-Voltage Power Cable (BS 6883 / BS 7917) engineered for 3.8/6.6 kV – 19/33 kV service across -40 to +90 °C (min. bend radius 12 × OD).
Halogen-free SHF1/SHF2 or mud-resistant thermoset jacket withstands marine salt mist, oil and deck weathering.
Approved for bulkheads, cable trays, ladders and hull penetrations on commercial vessels and offshore units.
Metallic braid armour and cross-linked EPR/XLPE/XLPO insulation handle heavy mechanical and thermal duty.
Stranded copper or tinned copper conductors terminate cleanly into marine switchboards, thrusters and transformers.
Armoured shipboard and offshore feeder cable is not designed for high-cycle automation drag chains.
Use Drag-Chain Servo CableConstruction
Shown: EBS2S & MBS2S 3.8/6.6-19/33 KV (BS 6883/7917 UKOOA) (BS 6883 & BS 7917 / UKOOA Code EBS2S & MBS2S (1.9/3.3 kV to 19/33 kV)) featuring tinned copper conductors (3×120 mm²), triple-extruded gp5 hf-epr mv insulation and red type sw4 mv outer jacket (2s) (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Tinned Copper Conductors (3×120 mm²) | BS EN 60228 Class 2 compacted tinned copper conductors |
| 2 | Triple-Extruded GP5 HF-EPR MV Insulation | Semi-con conductor screen + GP5 HF-EPR dielectric + insulation screen |
| 3 | Copper Tape Phase Metallic Screen | Helically lapped annealed copper tape screen on each core |
| 4 | Type SW4 Bedding & GSWB Armour (BS) | SW4 halogen-free inner sheath + galvanized steel wire braid armour |
| 5 | Red Type SW4 MV Outer Jacket (2S) | BS 6883 / BS 7917 red medium-voltage oil-resistant offshore sheath |
Built to BS 6883 & BS 7917 / UKOOA Code EBS2S & MBS2S (1.9/3.3 kV to 19/33 kV) with tinned copper conductors (3×120 mm²) and red type sw4 mv outer jacket (2s)
Available in custom continuous shipboard/offshore drum lengths or with marine EMC cable glands
Supplied with EN 10204 3.1 routine dielectric, conductor resistance & flame/fire test report
Technical data
Sizes
Manufactured to BS 6883 & BS 7917 / UKOOA Code EBS2S & MBS2S (1.9/3.3 kV to 19/33 kV) for shipboard, offshore platform, drilling rig and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| EBS2S & MBS2S 3.8/6.6-19/33 KV (BS 6883/7917 UKOOA) Construction Schedule (−40…+90 °C) | |||||||
| EBS2S 3×50 mm² MV | 3 × 50 mm² | IEC 60228 Class 2/5 Cu/SnCu | 42.5 | 2,980 | 22.5 | 510 | |
| EBS2S 3×95 mm² MV | 3 × 95 mm² | IEC 60228 Class 2/5 Cu/SnCu | 51.8 | 4,690 | 42.8 | 620 | |
| EBS2S 3×150 mm² MV | 3 × 150 mm² | IEC 60228 Class 2/5 Cu/SnCu | 61.2 | 6,840 | 67.5 | 735 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 3 × 50 mm² | 0.39 | 3.8/6.6 kV – 19/33 kV (195 A) | −40…+90 °C |
| 3 × 95 mm² | 0.19 | 3.8/6.6 kV – 19/33 kV (285 A) | −40…+90 °C |
| 3 × 150 mm² | 0.12 | 3.8/6.6 kV – 19/33 kV (365 A) | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (BS 6883 & BS 7917 / UKOOA Code EBS2S & MBS2S (1.9/3.3 kV to 19/33 kV)) | DC resistance at 20 °C / optical attenuation and outer diameter within BS 6883 & BS 7917 / UKOOA Code EBS2S & MBS2S (1.9/3.3 kV to 19/33 kV) tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (BS 6883 & BS 7917 / UKOOA Code EBS2S & MBS2S (1.9/3.3 kV to 19/33 kV)) | Zero dielectric breakdown and verified insulation resistance for 3.8/6.6 kV – 19/33 kV rating | Every manufactured drum length |
| Sample tests | ||
| Flame, fire integrity, oil/mud & mechanical qualification (BS 6883 & BS 7917 / UKOOA Code EBS2S & MBS2S (1.9/3.3 kV to 19/33 kV)) | Verified flame/fire performance, fluid resistance and thermal stability across −40…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking