Immersion & wet locations
Longitudinally and radially water-blocked construction resists hydrostatic pressure and marine immersion.
Product
Subsea Anode Sled & Buoyant Anode / Anode Mat Impressed Current Cathodic Protection (ICCP) Contra-Helical Double-Armored Subsea Feeder Cable & Type P XLPO MMO Anode Lead Cable (IEEE 1580 / DNV-RP-B401, 0.6/1 kV, -30 °C to +90 °C).
Typical values for this cable type, based on IEEE 1580 Type P / ASTM B33 / DNV-RP-B401 ICCP Standard — confirmed in the datasheet and quotation for your order.
Application fit
Subsea Anode Sled & Buoyant Anode / Anode Mat Impressed Current Cathodic Protection (ICCP) Contra-Helical Double-Armored Subsea Feeder Cable & Type P XLPO MMO Anode Lead Cable (IEEE 1580 / DNV-RP-B401, 0.6/1 kV, -30 °C to +90 °C).
Longitudinally and radially water-blocked construction resists hydrostatic pressure and marine immersion.
Marine-grade jacket resists oil, seawater, UV weathering and mechanical impact on vessels and offshore structures.
Approved for fixed shipboard, submarine outboard, nuclear pool and seabed feeder routing.
Flexible stranded copper conductors terminate cleanly into submersible pumps, anodes, thrusters and switchgear.
Outboard marine and feeder construction is not designed for high-speed crane festoon trolleys.
Use (N)3GRDC5G-J/O Festoon CableConstruction
Shown: ICCP ANODE & FEEDER CABLE (IEEE 1580 Type P / ASTM B33 / DNV-RP-B401 ICCP Standard) featuring stranded tinned copper (3×2 awg / 3×4/0 awg), dual-pass tpu/xlpe & 100% polyester wrap and black hdpe subsea outer jacket (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Stranded Tinned Copper (3×2 AWG / 3×4/0 AWG) | ASTM B33 soft annealed stranded tinned copper conductors (150–950 A DC ICCP) |
| 2 | Dual-Pass TPU/XLPE & 100% Polyester Wrap | 2-pass extruded TPU/XLPE insulation + 100% Polyester tape (Type P XLPO on MMO leads) |
| 3 | HDPE Fillers & Water-Blocking Yarns | Multiple sizes of HDPE filler rods + water-blocking yarn filling all cable voids |
| 4 | HDPE Bedding & Contra-Helical Double GSWA | Extruded HDPE bedding + 2-layer contra-helical galvanized steel wire armor (148 kN MBL) |
| 5 | Black HDPE Subsea Outer Jacket | Abrasion- and seawater-resistant high-density polyethylene outer sheath |
Built to IEEE 1580 Type P / ASTM B33 / DNV-RP-B401 ICCP Standard with stranded tinned copper (3×2 awg / 3×4/0 awg) and black hdpe subsea outer jacket
Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report
Technical data
Sizes
Manufactured to IEEE 1580 Type P / ASTM B33 / DNV-RP-B401 ICCP Standard for subsea, offshore, deep-well and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| ICCP ANODE & FEEDER CABLE Construction Schedule (−30…+90 °C) | |||||||
| ICCP ANODE Config A (Compact) | 4×2×24 AWG + 2×18 AWG (or 4C) | Stranded tinned Cu (IEC 60228 / ASTM) | 10.4 | 155 | 4.5 | 85 | |
| ICCP ANODE Config B (Standard) | 4×2×20 AWG + 4×16 AWG (or 8C) | Stranded tinned Cu (IEC 60228 / ASTM) | 13.3 | 265 | 9.6 | 110 | |
| ICCP ANODE Config C (Heavy Hybrid) | 8×2×20 AWG + 4×12 AWG (or 12C) | Stranded tinned Cu (IEC 60228 / ASTM) | 16.6 | 420 | 18.5 | 140 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4×2×24 AWG + 2×18 AWG (or 4C) | 28.40 | 0.6/1 kV (45–100 Ω data) | −30…+90 °C |
| 4×2×20 AWG + 4×16 AWG (or 8C) | 10.70 | 0.6/1 kV (45–100 Ω data) | −30…+90 °C |
| 8×2×20 AWG + 4×12 AWG (or 12C) | 5.40 | 0.6/1 kV (High-Power Hybrid) | −30…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (IEEE 1580 Type P / ASTM B33 / DNV-RP-B401 ICCP Standard) | DC resistance at 20 °C / optical attenuation and outer diameter within IEEE 1580 Type P / ASTM B33 / DNV-RP-B401 ICCP Standard tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (IEEE 1580 Type P / ASTM B33 / DNV-RP-B401 ICCP Standard) | Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, water-blocking & mechanical endurance qualification (IEEE 1580 Type P / ASTM B33 / DNV-RP-B401 ICCP Standard) | Verified submersion integrity, tensile load and thermal stability across −30…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.