EAF Anti-Chafing Bumper Water-Cooled Furnace CableReinforced bumper-ribbed water-cooled EAF cable resisting phase-to-phase rub

EAF Anti-Chafing Bumper adds thick vulcanized grey rubber bumper ribs over a water-cooled bare copper EAF hose to prevent mechanical chafing when parallel high-current phase cables whip during furnace arcing.

Flame-retardant
Oil-resistant
Approved
Order designation
EAF Anti-Chafing Bumper Cable 1×630 mm²
Outer Ø
78.0 mm
Max. R20
0.029 Ω/km
Weight
13,332 kg/km
Min. bend R
702 mm
All sizes (7)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
1000 V
Test voltage 4 kV AC
Temp. (fixed)
-25°C…+95°C
Flexing: -20 °C to +85 °C
Strength / Armor
Water Hose
Dual textile pressure braids +
Min. bend radius
9 × OD
High-current flexible routing
Conductor
Bare Cu · Cl.6
Per IEC 60228 Class 6
Size range
1×300–1×1200
7 standard configurations

Typical values for this cable type, based on IEC 60228 Class 6 · DIN VDE 0250 (ref.) · EN 50363-2-1 — confirmed in the datasheet and quotation for your order.

Application fit

Is EAF Anti-Chafing Bumper Cable right for your machine?

EAF Anti-Chafing Bumper adds thick vulcanized grey rubber bumper ribs over a water-cooled bare copper EAF hose to prevent mechanical chafing when parallel high-current phase cables whip during furnace arcing.

Furnace, kiln & high-temp zone

Suitable

Thermal-rated 1000 V EPDM build delivers stable high-current power near furnaces, ovens, kilns, and molten-metal zones.

Fixed installation

Suitable

Durable 1000 V EPDM geometry installs cleanly along transformer links, busbar transitions, trays, and industrial bays.

Cable trench & heavy drive bay

Suitable

Rugged 1000 V EPDM construction handles stationary heavy-plant cable trenches, rolling-mill feeders, and industrial power bays.

High-temperature boiler & thermal plant

Suitable

Thermal-aged 1000 V EPDM insulation maintains dielectric safety near industrial boilers, ovens, and high-ambient thermal equipment.

Energy chain / drag chain

Not suitable

1000 V EPDM construction is built for stationary or light-flex runs, not continuous high-cycle drag-chain flexing.

Use (N)12YRDC11Y-J/O PUR

Immersion & wet locations

Not suitable

1000 V EPDM outer sheath is not AD8-rated for permanent water submersion; specify a submersible EPDM or water-blocked cable.

Use EMC-VFD Submersible EPDM
Typical machinesElectric arc (EAF) & submerged arc (SAF) steelworksMedium- & high-frequency induction melting foundriesAutomotive robotic spot- & seam-welding linesHeavy DC rectifiers & metallurgical bus feeders

Construction

Layer by layer

Representative construction of EAF Anti-Chafing Bumper Cable: IEC 60228 Class 6 extra-flexible bare annealed copper, Pressurized water-cooled EPDM core + multi-rope bare copper conductor, and Grey abrasion- & impact-resistant vulcanized bumper rubber outer sheath.

1234
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1ConductorIEC 60228 Class 6 extra-flexible bare annealed copperIEC 60228 Class 6
2Cooling core / primary dielectricPressurized water-cooled EPDM core + multi-rope bare copper conductorIEC 60228 Class 6
3Strength / pressure reinforcementDual textile pressure braids + molded anti-chafing outer bumper layerIEC 60228 Class 6
4Outer sheath / hoseGrey abrasion- & impact-resistant vulcanized bumper rubber outer sheathAnti-Chafing Bumper Ribs

EAF Anti-Chafing Bumper Cable High-Duty

Single-core high-duty construction protected by Grey abrasion- & impact-resistant vulcanized bumper rubber outer sheath.

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on IEC 60228 Class 6 · DIN VDE 0250 (ref.) · EN 50363-2-1. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage
1000 V
Test voltage
4 kV AC
Conductor
Bare Cu · Cl.6
Core / dielectric
Pressurized water-cooled EPDM core +
Impedance / insulation
≥ 1,000 MΩ·km at 20 °C

Thermal

Temp. range (fixed)
-25 °C to +95 °C
Temp. range (flexing)
-20 °C to +85 °C
Peak / short-circuit
+160 °C (5 s)
Min. bending radius
9 × OD

Resistance

Primary performance
Anti-Chafing Bumper Ribs
Environment / duty
Electromagnetic Whip Proof
Mechanical / special
High-Pressure EPDM Core
Outer finish
Grey abrasion- & impact-resistant

Sizes

Water-Cooled High-Current Sizes (mm²)
Cross-section
mm²
Outer Ø ≈
mm
Max. R20
Ω/km
Copper index
kg/km
Weight ≈
kg/km
Min. bend R
9×D mm
1×300 mm²61.20.0642,8806,959551
1×400 mm²67.00.0493,8408,915603
1×500 mm²72.10.0384,80010,847649
1×630 mm²78.00.0296,04813,332702
1×800 mm²84.80.0247,68016,544763
1×1000 mm²92.00.0199,60020,302828
1×1200 mm²98.50.01611,52024,035886
  • Conductor DC resistance R20 at 20 °C per IEC 60228 Class 6.
  • Minimum bending radius calculated at 9 × nominal outer diameter (OD). Custom terminations available on request.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Hydrostatic pressure & dielectric test4 kV AC without breakdownEvery manufactured length
Continuity & conductor DC resistancePer IEC 60228 Class 6 at 20 °CEvery drum / assembly
Sample tests
Tensile, dimensional & pressure checkRated -25 °C to +95 °C continuousPer production lot
Environmental, thermal & mechanical qualificationAnti-Chafing Bumper Ribs · Electromagnetic Whip ProofType approval

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

IEC 60228 Class 6DIN VDE 0250 (ref.)EN 50363-2-1EN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

EAF Anti-Chafing Bumper Cable 1000 V TEBAOFLEX.COM [IEC 60228 Class 6] [Size] [Metre mark]
Delivery form
Custom assemblies, coils or export drums
Standard lengths
Cut-to-length · 100 m · 500 m · 1,000 m
MOQ
1 assembly / 50 m (stock) · 300 m (custom)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-11-23
Updated
2026-11-23

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What makes EAF Anti-Chafing Bumper Cable suited for demanding 1000 V installations?
EAF Anti-Chafing Bumper Cable combines IEC 60228 Class 6 extra-flexible bare annealed copper with Pressurized water-cooled EPDM core + multi-rope bare copper conductor and Grey abrasion- & impact-resistant vulcanized bumper rubber outer sheath. Heavy bumper jacket absorbs electromagnetic repulsion knocks between adjacent EAF phase cables.
What minimum bending radius should be respected for EAF Anti-Chafing Bumper Cable?
Maintain a minimum bending radius of 9 × OD across -20 °C to +85 °C flexing temperatures to ensure long mechanical and dielectric service life.
Can EAF Anti-Chafing Bumper Cable be delivered pre-terminated with custom lugs, water fittings, or subsea connectors?
Yes. TEBAOFLEX supplies EAF Anti-Chafing Bumper Cable either in bulk lengths or factory-assembled with copper lugs, water-cooled swivel fittings, or molded subsea wet-mate connectors.
What quality tests and certificates accompany every shipment of EAF Anti-Chafing Bumper Cable?
EAF Anti-Chafing Bumper Cable conforms to IEC 60228 Class 6, DIN VDE 0250 (ref.), EN 50363-2-1 (Anti-Chafing Bumper Ribs) and ships with an EN 10204 3.1 routine factory test certificate.
Which technical documents are available?
Reference files are provided for project screening. Final parameters and the applicable document package are confirmed during quotation.

Request a quote

Get an engineering quote for EAF Anti-Chafing Bumper Cable

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

EAF Anti-Chafing Bumper Water-Cooled Furnace Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote