Thermal-rated 1000 V EPDM build delivers stable high-current power near furnaces, ovens, kilns, and molten-metal zones.
Product
EAF Anti-Chafing Bumper adds thick vulcanized grey rubber bumper ribs over a water-cooled bare copper EAF hose to prevent mechanical chafing when parallel high-current phase cables whip during furnace arcing.
Typical values for this cable type, based on IEC 60228 Class 6 · DIN VDE 0250 (ref.) · EN 50363-2-1 — confirmed in the datasheet and quotation for your order.
Application fit
EAF Anti-Chafing Bumper adds thick vulcanized grey rubber bumper ribs over a water-cooled bare copper EAF hose to prevent mechanical chafing when parallel high-current phase cables whip during furnace arcing.
Thermal-rated 1000 V EPDM build delivers stable high-current power near furnaces, ovens, kilns, and molten-metal zones.
Durable 1000 V EPDM geometry installs cleanly along transformer links, busbar transitions, trays, and industrial bays.
Rugged 1000 V EPDM construction handles stationary heavy-plant cable trenches, rolling-mill feeders, and industrial power bays.
Thermal-aged 1000 V EPDM insulation maintains dielectric safety near industrial boilers, ovens, and high-ambient thermal equipment.
1000 V EPDM construction is built for stationary or light-flex runs, not continuous high-cycle drag-chain flexing.
Use (N)12YRDC11Y-J/O PUR1000 V EPDM outer sheath is not AD8-rated for permanent water submersion; specify a submersible EPDM or water-blocked cable.
Use EMC-VFD Submersible EPDMConstruction
Representative construction of EAF Anti-Chafing Bumper Cable: IEC 60228 Class 6 extra-flexible bare annealed copper, Pressurized water-cooled EPDM core + multi-rope bare copper conductor, and Grey abrasion- & impact-resistant vulcanized bumper rubber outer sheath.
| # | Layer | Material & reference |
|---|---|---|
| 1 | Conductor | IEC 60228 Class 6 extra-flexible bare annealed copperIEC 60228 Class 6 |
| 2 | Cooling core / primary dielectric | Pressurized water-cooled EPDM core + multi-rope bare copper conductorIEC 60228 Class 6 |
| 3 | Strength / pressure reinforcement | Dual textile pressure braids + molded anti-chafing outer bumper layerIEC 60228 Class 6 |
| 4 | Outer sheath / hose | Grey abrasion- & impact-resistant vulcanized bumper rubber outer sheathAnti-Chafing Bumper Ribs |
Single-core high-duty construction protected by Grey abrasion- & impact-resistant vulcanized bumper rubber outer sheath.
Technical data
Sizes
| Cross-section mm² | Outer Ø ≈ mm | Max. R20 Ω/km | Copper index kg/km | Weight ≈ kg/km | Min. bend R 9×D mm |
|---|---|---|---|---|---|
| 1×300 mm² | 61.2 | 0.064 | 2,880 | 6,959 | 551 |
| 1×400 mm² | 67.0 | 0.049 | 3,840 | 8,915 | 603 |
| 1×500 mm² | 72.1 | 0.038 | 4,800 | 10,847 | 649 |
| 1×630 mm² | 78.0 | 0.029 | 6,048 | 13,332 | 702 |
| 1×800 mm² | 84.8 | 0.024 | 7,680 | 16,544 | 763 |
| 1×1000 mm² | 92.0 | 0.019 | 9,600 | 20,302 | 828 |
| 1×1200 mm² | 98.5 | 0.016 | 11,520 | 24,035 | 886 |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Hydrostatic pressure & dielectric test | 4 kV AC without breakdown | Every manufactured length |
| Continuity & conductor DC resistance | Per IEC 60228 Class 6 at 20 °C | Every drum / assembly |
| Sample tests | ||
| Tensile, dimensional & pressure check | Rated -25 °C to +95 °C continuous | Per production lot |
| Environmental, thermal & mechanical qualification | Anti-Chafing Bumper Ribs · Electromagnetic Whip Proof | Type approval |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.