Immersion & wet locations
Longitudinally and radially water-blocked construction resists hydrostatic pressure and marine immersion.
Product
MIL-DTL-915/8H Types DSS, TSS, FSS & 7SS 600 V Submarine Outboard Pressure-Tight Shielded Hydrophone & Sonar Rubber Cable (For Outboard Use Only) (MIL-DTL-915/8H, 600 V, -40 °C to +80 °C, min. bend radius 8 × OD).
Typical values for this cable type, based on MIL-DTL-915/8H Types DSS / TSS / FSS / 7SS Outboard Standard — confirmed in the datasheet and quotation for your order.
Application fit
MIL-DTL-915/8H Types DSS, TSS, FSS & 7SS 600 V Submarine Outboard Pressure-Tight Shielded Hydrophone & Sonar Rubber Cable (For Outboard Use Only) (MIL-DTL-915/8H, 600 V, -40 °C to +80 °C, min. bend radius 8 × OD).
Longitudinally and radially water-blocked construction resists hydrostatic pressure and marine immersion.
Marine-grade jacket resists oil, seawater, UV weathering and mechanical impact on vessels and offshore structures.
Approved for fixed shipboard, submarine outboard, nuclear pool and seabed feeder routing.
Flexible stranded copper conductors terminate cleanly into submersible pumps, anodes, thrusters and switchgear.
Outboard marine and feeder construction is not designed for high-speed crane festoon trolleys.
Use (N)3GRDC5G-J/O Festoon CableConstruction
Shown: MIL-DTL-915/8H (DSS / TSS / FSS / 7SS) (MIL-DTL-915/8H Types DSS / TSS / FSS / 7SS Outboard Standard) featuring blocked 7-strand tinned cu (dss/tss/fss/7ss), 600 v synthetic rubber insulation and heavy-duty polychloroprene jacket (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Blocked 7-Strand Tinned Cu (DSS/TSS/FSS/7SS) | Navy Strand blocked tinned copper conductors (18, 16 & 14 AWG; 500 psi zero leak) |
| 2 | 600 V Synthetic Rubber Insulation | 0.51–0.64 mm synthetic rubber insulation (3,000 V RMS / 5 min core-to-core test) |
| 3 | Strippable Synthetic Rubber Inner Belt | 0.76 mm (0.030") synthetic rubber inner belting & fillers stripping clean from cores |
| 4 | Tinned Copper Braid Shield (≥90%) | 34 AWG tinned copper wire braid (≥50° braid angle, ≥90% optical coverage) |
| 5 | Heavy-Duty Polychloroprene Jacket | 1.27–2.16 mm black polychloroprene rubber jacket (–40 °C mandrel bend qualified) |
Built to MIL-DTL-915/8H Types DSS / TSS / FSS / 7SS Outboard Standard with blocked 7-strand tinned cu (dss/tss/fss/7ss) and heavy-duty polychloroprene jacket
Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report
Technical data
Sizes
Manufactured to MIL-DTL-915/8H Types DSS / TSS / FSS / 7SS Outboard Standard for subsea, offshore, deep-well and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| MIL-DTL-915/8H (DSS / TSS / FSS / 7SS) Construction Schedule (−40…+80 °C) | |||||||
| MIL-DTL-915 Config A (Compact) | 4×2×24 AWG + 2×18 AWG (or 4C) | Stranded tinned Cu (IEC 60228 / ASTM) | 10.4 | 155 | 4.5 | 85 | |
| MIL-DTL-915 Config B (Standard) | 4×2×20 AWG + 4×16 AWG (or 8C) | Stranded tinned Cu (IEC 60228 / ASTM) | 13.3 | 265 | 9.6 | 110 | |
| MIL-DTL-915 Config C (Heavy Hybrid) | 8×2×20 AWG + 4×12 AWG (or 12C) | Stranded tinned Cu (IEC 60228 / ASTM) | 16.6 | 420 | 18.5 | 140 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4×2×24 AWG + 2×18 AWG (or 4C) | 28.40 | 600 V (45–100 Ω data) | −40…+80 °C |
| 4×2×20 AWG + 4×16 AWG (or 8C) | 10.70 | 600 V (45–100 Ω data) | −40…+80 °C |
| 8×2×20 AWG + 4×12 AWG (or 12C) | 5.40 | 600 V (High-Power Hybrid) | −40…+80 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (MIL-DTL-915/8H Types DSS / TSS / FSS / 7SS Outboard Standard) | DC resistance at 20 °C / optical attenuation and outer diameter within MIL-DTL-915/8H Types DSS / TSS / FSS / 7SS Outboard Standard tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (MIL-DTL-915/8H Types DSS / TSS / FSS / 7SS Outboard Standard) | Zero dielectric breakdown and verified insulation resistance for 600 V rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, water-blocking & mechanical endurance qualification (MIL-DTL-915/8H Types DSS / TSS / FSS / 7SS Outboard Standard) | Verified submersion integrity, tensile load and thermal stability across −40…+80 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.