Offshore platform & shipboard deck trays
Halogen-free SHF1/SHF2 or mud-resistant thermoset jacket withstands marine salt mist, oil and deck weathering.
Product
HF-TPYC, HF-TPYCY & HF-FPYC 0.6/1 kV (JIS C 3410) Halogen-Free EPR/XLPE-Insulated Steel-Wire Braided SHF1 Three & Four-Core Shipboard Main Power Cable (JIS C 3410 / IEC 60092-353, 0.6/1 kV, -40 to +90 °C, min. bend radius 6 × OD).
Typical values for this cable type, based on JIS C 3410:2018 & IEC 60092-353 / IEC 60332-3-22 Cat. A — confirmed in the datasheet and quotation for your order.
Application fit
HF-TPYC, HF-TPYCY & HF-FPYC 0.6/1 kV (JIS C 3410) Halogen-Free EPR/XLPE-Insulated Steel-Wire Braided SHF1 Three & Four-Core Shipboard Main Power Cable (JIS C 3410 / IEC 60092-353, 0.6/1 kV, -40 to +90 °C, min. bend radius 6 × OD).
Halogen-free SHF1/SHF2 or mud-resistant thermoset jacket withstands marine salt mist, oil and deck weathering.
Approved for bulkheads, cable trays, ladders and hull penetrations on commercial vessels and offshore units.
Metallic braid armour and cross-linked EPR/XLPE/XLPO insulation handle heavy mechanical and thermal duty.
Stranded copper or tinned copper conductors terminate cleanly into marine switchboards, thrusters and transformers.
Armoured shipboard and offshore feeder cable is not designed for high-cycle automation drag chains.
Use Drag-Chain Servo CableConstruction
Shown: HF-TPYC & HF-TPYCY / HF-FPYC 0.6/1 KV (JIS C 3410) (JIS C 3410:2018 & IEC 60092-353 / IEC 60332-3-22 Cat. A) featuring tinned copper conductors (3×35 mm²), jis color-coded hf-epr/xlpe insulation and shf1 zero-halogen outer sheath (hf-tpycy) (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Tinned Copper Conductors (3×35 mm²) | JIS C 3410 stranded tinned annealed copper conductors |
| 2 | JIS Color-Coded HF-EPR/XLPE Insulation | 90 °C halogen-free insulation coded Black, White, Red (plus Green in 4C) |
| 3 | Halogen-Free Bedding & Filler | Flame-retardant non-hygroscopic inner covering |
| 4 | Galvanized Steel Wire Braid Armour (C) | High-coverage galvanized steel wire braid armour |
| 5 | SHF1 Zero-Halogen Outer Sheath (HF-TPYCY | Black low-smoke zero-halogen polyolefin jacket |
Built to JIS C 3410:2018 & IEC 60092-353 / IEC 60332-3-22 Cat. A with tinned copper conductors (3×35 mm²) and shf1 zero-halogen outer sheath (hf-tpycy)
Available in custom continuous shipboard/offshore drum lengths or with marine EMC cable glands
Supplied with EN 10204 3.1 routine dielectric, conductor resistance & flame/fire test report
Technical data
Sizes
Manufactured to JIS C 3410:2018 & IEC 60092-353 / IEC 60332-3-22 Cat. A for shipboard, offshore platform, drilling rig and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| HF-TPYC & HF-TPYCY / HF-FPYC 0.6/1 KV (JIS C 3410) Construction Schedule (−40…+90 °C) | |||||||
| HF-TPYC 3×16+1G16 mm² | 3 × 16 + 1G16 mm² (4G16) | IEC 60228 Class 2/5 Cu/SnCu | 22.4 | 920 | 3.8 | 135 | |
| HF-TPYC 3×35+1G16 mm² | 3 × 35 + 1G16 mm² (4G35) | IEC 60228 Class 2/5 Cu/SnCu | 28.8 | 1,690 | 7.4 | 175 | |
| HF-TPYC 3×70+1G35 mm² | 3 × 70 + 1G35 mm² (4G70) | IEC 60228 Class 2/5 Cu/SnCu | 38.2 | 3,260 | 14.8 | 230 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 3 × 16 + 1G16 mm² (4G16) | 1.15 | 0.6/1 kV (98 A) | −40…+90 °C |
| 3 × 35 + 1G16 mm² (4G35) | 0.52 | 0.6/1 kV (158 A) | −40…+90 °C |
| 3 × 70 + 1G35 mm² (4G70) | 0.27 | 0.6/1 kV (245 A) | −40…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (JIS C 3410:2018 & IEC 60092-353 / IEC 60332-3-22 Cat. A) | DC resistance at 20 °C / optical attenuation and outer diameter within JIS C 3410:2018 & IEC 60092-353 / IEC 60332-3-22 Cat. A tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (JIS C 3410:2018 & IEC 60092-353 / IEC 60332-3-22 Cat. A) | Zero dielectric breakdown and verified insulation resistance for 0.6/1 kV rating | Every manufactured drum length |
| Sample tests | ||
| Flame, fire integrity, oil/mud & mechanical qualification (JIS C 3410:2018 & IEC 60092-353 / IEC 60332-3-22 Cat. A) | Verified flame/fire performance, fluid resistance and thermal stability across −40…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.