EAF Water-Cooled Cable with Dual-Layer Wear-Indicator HoseElectric arc furnace water-cooled cable with contrasting abrasion-alert hose

EAF Wear-Indicator Hose pairs high-current Class 6 bare copper ropes and internal water cooling with a dual-colour EPDM outer hose that reveals a bright inner indicator layer before molten-zone abrasion reaches pressure braids.

Flame-retardant
Oil-resistant
Approved
Order designation
EAF Wear-Indicator Hose Cable 1×630 mm²
Outer Ø
72.0 mm
Max. R20
0.029 Ω/km
Weight
12,684 kg/km
Min. bend R
576 mm
All sizes (7)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
1000 V
Test voltage 4 kV AC
Temp. (fixed)
-25°C…+95°C
Flexing: -20 °C to +85 °C
Strength / Armor
Aramid Braid
Dual synthetic/aramid pressure
Min. bend radius
8 × OD
High-current flexible routing
Conductor
Bare Cu · Cl.6
Per DIN VDE 0250 (ref.)
Size range
1×300–1×1200
7 standard configurations

Typical values for this cable type, based on DIN VDE 0250 (ref.) · IEC 60228 Class 6 · EN 50363-2-1 — confirmed in the datasheet and quotation for your order.

Application fit

Is EAF Wear-Indicator Hose Cable right for your machine?

EAF Wear-Indicator Hose pairs high-current Class 6 bare copper ropes and internal water cooling with a dual-colour EPDM outer hose that reveals a bright inner indicator layer before molten-zone abrasion reaches pressure braids.

Furnace, kiln & high-temp zone

Suitable

Thermal-rated 1000 V EPDM build delivers stable high-current power near furnaces, ovens, kilns, and molten-metal zones.

Fixed installation

Suitable

Durable 1000 V EPDM geometry installs cleanly along transformer links, busbar transitions, trays, and industrial bays.

Cable trench & heavy drive bay

Suitable

Rugged 1000 V EPDM construction handles stationary heavy-plant cable trenches, rolling-mill feeders, and industrial power bays.

High-temperature boiler & thermal plant

Suitable

Thermal-aged 1000 V EPDM insulation maintains dielectric safety near industrial boilers, ovens, and high-ambient thermal equipment.

Energy chain / drag chain

Not suitable

1000 V EPDM construction is built for stationary or light-flex runs, not continuous high-cycle drag-chain flexing.

Use (N)12YRDC11Y-J/O PUR

Immersion & wet locations

Not suitable

1000 V EPDM outer sheath is not AD8-rated for permanent water submersion; specify a submersible EPDM or water-blocked cable.

Use EMC-VFD Submersible EPDM
Typical machinesElectric arc (EAF) & submerged arc (SAF) steelworksMedium- & high-frequency induction melting foundriesAutomotive robotic spot- & seam-welding linesHeavy DC rectifiers & metallurgical bus feeders

Construction

Layer by layer

Representative construction of EAF Wear-Indicator Hose Cable: IEC 60228 Class 6 extra-flexible bare annealed copper, Central water-cooled bare copper rope bundle + contrasting warning inner rubber, and Black heavy-duty EPDM rubber outer hose with high-contrast wear-indicator sub-layer.

1234
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1ConductorIEC 60228 Class 6 extra-flexible bare annealed copperIEC 60228 Class 6
2Cooling core / primary dielectricCentral water-cooled bare copper rope bundle + contrasting warning inner rubberDIN VDE 0250 (ref.)
3Strength / pressure reinforcementDual synthetic/aramid pressure reinforcement braidsDIN VDE 0250 (ref.)
4Outer sheath / hoseBlack heavy-duty EPDM rubber outer hose with high-contrast wear-indicator sub-layerVisual Wear-Alert Layer

EAF Wear-Indicator Hose Cable High-Duty

Single-core high-duty construction protected by Black heavy-duty EPDM rubber outer hose with high-contrast wear-indicator sub-layer.

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on DIN VDE 0250 (ref.) · IEC 60228 Class 6 · EN 50363-2-1. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage
1000 V
Test voltage
4 kV AC
Conductor
Bare Cu · Cl.6
Core / dielectric
Central water-cooled bare copper rope
Impedance / insulation
≥ 1,000 MΩ·km at 20 °C

Thermal

Temp. range (fixed)
-25 °C to +95 °C
Temp. range (flexing)
-20 °C to +85 °C
Peak / short-circuit
+160 °C (5 s)
Min. bending radius
8 × OD

Resistance

Primary performance
Visual Wear-Alert Layer
Environment / duty
Arc-Furnace Slag Resistant
Mechanical / special
High-Pressure Water Hose
Outer finish
Black heavy-duty EPDM rubber outer hose

Sizes

Water-Cooled High-Current Sizes (mm²)
Cross-section
mm²
Outer Ø ≈
mm
Max. R20
Ω/km
Copper index
kg/km
Weight ≈
kg/km
Min. bend R
8×D mm
1×300 mm²55.20.0642,8806,456442
1×400 mm²61.00.0493,8408,362488
1×500 mm²66.10.0384,80010,250529
1×630 mm²72.00.0296,04812,684576
1×800 mm²78.80.0247,68015,837630
1×1000 mm²86.00.0199,60019,533688
1×1200 mm²92.50.01611,52023,210740
  • Conductor DC resistance R20 at 20 °C per IEC 60228 Class 6.
  • Minimum bending radius calculated at 8 × nominal outer diameter (OD). Custom terminations available on request.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Hydrostatic pressure & dielectric test4 kV AC without breakdownEvery manufactured length
Continuity & conductor DC resistancePer IEC 60228 Class 6 at 20 °CEvery drum / assembly
Sample tests
Tensile, dimensional & pressure checkRated -25 °C to +95 °C continuousPer production lot
Environmental, thermal & mechanical qualificationVisual Wear-Alert Layer · Arc-Furnace Slag ResistantType approval

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

DIN VDE 0250 (ref.)IEC 60228 Class 6EN 50363-2-1EN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

EAF Wear-Indicator Hose Cable 1000 V TEBAOFLEX.COM [DIN VDE 0250 (ref.)] [Size] [Metre mark]
Delivery form
Custom assemblies, coils or export drums
Standard lengths
Cut-to-length · 100 m · 500 m · 1,000 m
MOQ
1 assembly / 50 m (stock) · 300 m (custom)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-11-23
Updated
2026-11-23

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What makes EAF Wear-Indicator Hose Cable suited for demanding 1000 V installations?
EAF Wear-Indicator Hose Cable combines IEC 60228 Class 6 extra-flexible bare annealed copper with Central water-cooled bare copper rope bundle + contrasting warning inner rubber and Black heavy-duty EPDM rubber outer hose with high-contrast wear-indicator sub-layer. Visual wear-indicator sub-layer enables scheduled EAF cable swaps before sudden coolant rupture.
What minimum bending radius should be respected for EAF Wear-Indicator Hose Cable?
Maintain a minimum bending radius of 8 × OD across -20 °C to +85 °C flexing temperatures to ensure long mechanical and dielectric service life.
Can EAF Wear-Indicator Hose Cable be delivered pre-terminated with custom lugs, water fittings, or subsea connectors?
Yes. TEBAOFLEX supplies EAF Wear-Indicator Hose Cable either in bulk lengths or factory-assembled with copper lugs, water-cooled swivel fittings, or molded subsea wet-mate connectors.
What quality tests and certificates accompany every shipment of EAF Wear-Indicator Hose Cable?
EAF Wear-Indicator Hose Cable conforms to DIN VDE 0250 (ref.), IEC 60228 Class 6, EN 50363-2-1 (Visual Wear-Alert Layer) and ships with an EN 10204 3.1 routine factory test certificate.
Which technical documents are available?
Reference files are provided for project screening. Final parameters and the applicable document package are confirmed during quotation.

Request a quote

Get an engineering quote for EAF Wear-Indicator Hose Cable

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

EAF Water-Cooled Cable with Dual-Layer Wear-Indicator Hose

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote