Immersion & wet locations
Longitudinally and radially water-blocked construction resists hydrostatic pressure and marine immersion.
Product
German Military Standard VG 95218-29 (Types B to N: LWDC, PLWDC, PLWDCC, PLWDC-C, LWD) 61 bar Pressure-Resistant Submarine Outboard Watertight Cable (VG 95218-29 (61 bar), 600 V, -30 °C to +85 °C, min. bend radius 8 × OD).
Typical values for this cable type, based on German Military VG 95218-29 (Types B–N) 61 bar Outboard — confirmed in the datasheet and quotation for your order.
Application fit
German Military Standard VG 95218-29 (Types B to N: LWDC, PLWDC, PLWDCC, PLWDC-C, LWD) 61 bar Pressure-Resistant Submarine Outboard Watertight Cable (VG 95218-29 (61 bar), 600 V, -30 °C to +85 °C, min. bend radius 8 × OD).
Longitudinally and radially water-blocked construction resists hydrostatic pressure and marine immersion.
Marine-grade jacket resists oil, seawater, UV weathering and mechanical impact on vessels and offshore structures.
Approved for fixed shipboard, submarine outboard, nuclear pool and seabed feeder routing.
Flexible stranded copper conductors terminate cleanly into submersible pumps, anodes, thrusters and switchgear.
Outboard marine and feeder construction is not designed for high-speed crane festoon trolleys.
Use (N)3GRDC5G-J/O Festoon CableConstruction
Shown: VG 95218-29 (LWDC / PLWDC / PLWDC-C) (German Military VG 95218-29 (Types B–N) 61 bar Outboard) featuring water-blocked conductors (4×2×0.75 mm²), isolated pair braid & inner covering and halogen-free pur / lszh outer sheath (5-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Water-Blocked Conductors (4×2×0.75 mm²) | Fine-stranded tin-plated copper + black white-numbered special elastomer |
| 2 | Isolated Pair Braid & Inner Covering | Tin-plated copper braid per pair + extruded elastomer inner covering (Type L / F) |
| 3 | Water-Blocking Fillers & Swelling Tapes | Longitudinal water-blocking fillers + lapped water-blocking tapes (61 bar rated) |
| 4 | Outer Tinned Copper Braid Shield | High-density tin-plated copper braid outer shield (Zt ≤ 15 mΩ/m) |
| 5 | Halogen-Free PUR / LSZH Outer Sheath | Black flame-retardant polyurethane HFS 100 (Type G–N) or LSZH elastomer (Type B–F) |
Built to German Military VG 95218-29 (Types B–N) 61 bar Outboard with water-blocked conductors (4×2×0.75 mm²) and halogen-free pur / lszh outer sheath
Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies
Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report
Technical data
Sizes
Manufactured to German Military VG 95218-29 (Types B–N) 61 bar Outboard for subsea, offshore, deep-well and marine applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Tensile rating kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| VG 95218-29 (LWDC / PLWDC / PLWDC-C) Construction Schedule (−30…+85 °C) | |||||||
| VG 95218-29 Config A (Compact) | 4×2×24 AWG + 2×18 AWG (or 4C) | Stranded tinned Cu (IEC 60228 / ASTM) | 10.4 | 155 | 4.5 | 85 | |
| VG 95218-29 Config B (Standard) | 4×2×20 AWG + 4×16 AWG (or 8C) | Stranded tinned Cu (IEC 60228 / ASTM) | 13.3 | 265 | 9.6 | 110 | |
| VG 95218-29 Config C (Heavy Hybrid) | 8×2×20 AWG + 4×12 AWG (or 12C) | Stranded tinned Cu (IEC 60228 / ASTM) | 16.6 | 420 | 18.5 | 140 | |
| Configuration | Max. DC R₂₀ / Atten. Ω/km or dB/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 4×2×24 AWG + 2×18 AWG (or 4C) | 28.40 | 600 V (45–100 Ω data) | −30…+85 °C |
| 4×2×20 AWG + 4×16 AWG (or 8C) | 10.70 | 600 V (45–100 Ω data) | −30…+85 °C |
| 8×2×20 AWG + 4×12 AWG (or 12C) | 5.40 | 600 V (High-Power Hybrid) | −30…+85 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor resistance, continuity & dimensional verification (German Military VG 95218-29 (Types B–N) 61 bar Outboard) | DC resistance at 20 °C / optical attenuation and outer diameter within German Military VG 95218-29 (Types B–N) 61 bar Outboard tolerances | Every manufactured drum length |
| High-voltage dielectric & insulation resistance test (German Military VG 95218-29 (Types B–N) 61 bar Outboard) | Zero dielectric breakdown and verified insulation resistance for 600 V rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, water-blocking & mechanical endurance qualification (German Military VG 95218-29 (Types B–N) 61 bar Outboard) | Verified submersion integrity, tensile load and thermal stability across −30…+85 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.