Contact

VG 95218-29 (LWDC / PLWDC / PLWDC-C) 61 bar Submarine Outboard CableVG 95218-29 (61 bar) · 600 V · Vg 95218-29 61 bar pressure-resistant submarine

German Military Standard VG 95218-29 (Types B to N: LWDC, PLWDC, PLWDCC, PLWDC-C, LWD) 61 bar Pressure-Resistant Submarine Outboard Watertight Cable (VG 95218-29 (61 bar), 600 V, -30 °C to +85 °C, min. bend radius 8 × OD).

Water-resistant
EMC screen
Flame-retardant
Approved
Order designation
VG 95218-29 Config A (Compact)
Outer Ø ≈
10.4 mm
Net weight ≈
155 kg/km
Tensile rating ≈
4.5 kN
Core / stranding
Stranded tinned Cu (IEC 60228 / ASTM)
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
600 V
Tested per VG 95218-29 (61 bar)
Operating temp.
−30…+85 °C
Continuous subsea & marine service
Min. bend radius
8 × OD
Dynamic sheave & fixed routing
Core / conductor
1C–37C
Longitudinally water-blocked
Outer protection
HFS 100 PUR/LSZH
Halogen-free flame-retardant PUR HFS 100
Standard
VG 95218-29
German Military VG 95218-29 61 bar

Typical values for this cable type, based on German Military VG 95218-29 (Types B–N) 61 bar Outboard — confirmed in the datasheet and quotation for your order.

Application fit

Is VG 95218-29 (LWDC / PLWDC / PLWDC-C) right for your machine?

German Military Standard VG 95218-29 (Types B to N: LWDC, PLWDC, PLWDCC, PLWDC-C, LWD) 61 bar Pressure-Resistant Submarine Outboard Watertight Cable (VG 95218-29 (61 bar), 600 V, -30 °C to +85 °C, min. bend radius 8 × OD).

Immersion & wet locations

Suitable

Longitudinally and radially water-blocked construction resists hydrostatic pressure and marine immersion.

Offshore platform & shipboard deck trays

Suitable

Marine-grade jacket resists oil, seawater, UV weathering and mechanical impact on vessels and offshore structures.

Fixed installation

Suitable

Approved for fixed shipboard, submarine outboard, nuclear pool and seabed feeder routing.

Motor stator, traction & converter leads

Suitable

Flexible stranded copper conductors terminate cleanly into submersible pumps, anodes, thrusters and switchgear.

Typical machinesMarine & Offshore CableNaval Shipboard & Submarine OutboardOffshore Cathodic Protection (ICCP)Underwater Welding & Nuclear PoolsDeep-Well & Seabed Pump Feeders

Construction

Layer by layer

Shown: VG 95218-29 (LWDC / PLWDC / PLWDC-C) (German Military VG 95218-29 (Types B–N) 61 bar Outboard) featuring water-blocked conductors (4×2×0.75 mm²), isolated pair braid & inner covering and halogen-free pur / lszh outer sheath (5-layer construction).

12345
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Water-Blocked Conductors (4×2×0.75 mm²)Fine-stranded tin-plated copper + black white-numbered special elastomer
2Isolated Pair Braid & Inner CoveringTin-plated copper braid per pair + extruded elastomer inner covering (Type L / F)
3Water-Blocking Fillers & Swelling TapesLongitudinal water-blocking fillers + lapped water-blocking tapes (61 bar rated)
4Outer Tinned Copper Braid ShieldHigh-density tin-plated copper braid outer shield (Zt ≤ 15 mΩ/m)
5Halogen-Free PUR / LSZH Outer SheathBlack flame-retardant polyurethane HFS 100 (Type G–N) or LSZH elastomer (Type B–F)

VG 95218-29 (LWDC / PLWDC / PLWDC-C) — Standard Subsea & Marine Execution

Built to German Military VG 95218-29 (Types B–N) 61 bar Outboard with water-blocked conductors (4×2×0.75 mm²) and halogen-free pur / lszh outer sheath

VG 95218-29 (LWDC / PLWDC / PLWDC-C) — Custom Drum Length & Termination Kit

Available in custom continuous subsea/wellbore drum lengths or pre-terminated assemblies

VG 95218-29 (LWDC / PLWDC / PLWDC-C) — Routine & Hydrostatic Test Certified

Supplied with EN 10204 3.1 routine dielectric, resistance & pressure/dimensional report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on German Military VG 95218-29 (Types B–N) 61 bar Outboard. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / transmission duty
600 V (German Military VG 95218-29 (Types B–N) 61 bar Outboard)
Core / conductor construction
Water-Blocked Conductors (4×2×0.75 mm²) — Fine-stranded tin-plated copper + black white-numbered special elastomer
Primary dielectric / buffering
Isolated Pair Braid & Inner Covering — Tin-plated copper braid per pair + extruded elastomer inner covering (Type L / F)

Thermal

Continuous operating temperature
−30…+85 °C (subsea, marine & submersible duty)
Short-circuit / peak thermal rating
Verified thermal stability per German Military VG 95218-29 (Types B–N) 61 bar Outboard
Storage & transport temperature
−40…+80 °C on export wooden/steel drum

Mechanical

Outer protection / armouring
Halogen-Free PUR / LSZH Outer Sheath — Black flame-retardant polyurethane HFS 100 (Type G–N) or LSZH elastomer (Type B–F)
Minimum bending radius
8 × OD
Hydrostatic, tensile & crush duty
Outer Tinned Copper Braid Shield — High-density tin-plated copper braid outer shield (Zt ≤ 15 mΩ/m)

Resistance

Hydrostatic pressure & water blocking
Engineered for continuous submersion and hydrostatic integrity per German Military VG 95218-29 (Types B–N) 61 bar Outboard
Seawater, oil & chemical resistance
Resistant to seawater hydrolysis, hydraulic oils and abrasion per German Military VG 95218-29 (Types B–N) 61 bar Outboard
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
German Military VG 95218-29 (Types B–N) 61 bar Outboard
Environmental & test standards
IEC 60228 / IEC 60332 / ISO 13628-5 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
VG 95218-29 (LWDC / PLWDC / PLWDC-C)
Sheath colour & metre marking
Continuous metre-marked black outer finish (HFS 100 PUR / LSZH (61 bar))
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard VG 95218-29 (LWDC / PLWDC / PLWDC-C) subsea & marine configurations

Manufactured to German Military VG 95218-29 (Types B–N) 61 bar Outboard for subsea, offshore, deep-well and marine applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Tensile rating
kN ≈
Min. bend R
mm
Enquiry
VG 95218-29 (LWDC / PLWDC / PLWDC-C) Construction Schedule (−30…+85 °C)
VG 95218-29 Config A (Compact)4×2×24 AWG + 2×18 AWG (or 4C)Stranded tinned Cu (IEC 60228 / ASTM)10.41554.585
VG 95218-29 Config B (Standard)4×2×20 AWG + 4×16 AWG (or 8C)Stranded tinned Cu (IEC 60228 / ASTM)13.32659.6110
VG 95218-29 Config C (Heavy Hybrid)8×2×20 AWG + 4×12 AWG (or 12C)Stranded tinned Cu (IEC 60228 / ASTM)16.642018.5140
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core cross-sections, pair/fibre counts, armour grades and factory drum lengths available per German Military VG 95218-29 (Types B–N) 61 bar Outboard.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance, continuity & dimensional verification (German Military VG 95218-29 (Types B–N) 61 bar Outboard)DC resistance at 20 °C / optical attenuation and outer diameter within German Military VG 95218-29 (Types B–N) 61 bar Outboard tolerancesEvery manufactured drum length
High-voltage dielectric & insulation resistance test (German Military VG 95218-29 (Types B–N) 61 bar Outboard)Zero dielectric breakdown and verified insulation resistance for 600 V ratingEvery manufactured drum length
Sample tests
Hydrostatic pressure, water-blocking & mechanical endurance qualification (German Military VG 95218-29 (Types B–N) 61 bar Outboard)Verified submersion integrity, tensile load and thermal stability across −30…+85 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

VG 95218-29 (61 bar) CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX VG 95218-29 (LWDC / PLWDC / PLWDC-C) VG 95218-29 (61 bar) 600 V CE
Delivery form
Heavy-duty export fumigated wooden drums or steel subsea reels
Standard lengths
500 m, 1,000 m or custom continuous subsea/wellbore lengths
MOQ
100 m (standard configurations) · 500 m (custom builds)
Lead time
2–5 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-25
Updated
2026-10-25

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define VG 95218-29 (LWDC / PLWDC / PLWDC-C) (VG 95218-29 (LWDC / PLWDC / PLWDC-C) 61 bar Submarine Outboard Cable)?
VG 95218-29 (LWDC / PLWDC / PLWDC-C) (VG 95218-29 (LWDC / PLWDC / PLWDC-C) 61 bar Submarine Outboard Cable) is manufactured in accordance with German Military VG 95218-29 (Types B–N) 61 bar Outboard for 600 V service over -30 °C to +85 °C. Its 5-layer construction comprises water-blocked conductors (4×2×0.75 mm²), isolated pair braid & inner covering and halogen-free pur / lszh outer sheath.
What is the minimum bending radius and operating temperature range for VG 95218-29 (LWDC / PLWDC / PLWDC-C)?
The minimum bending radius for VG 95218-29 (LWDC / PLWDC / PLWDC-C) is 8 × OD across its continuous operating temperature range of -30 °C to +85 °C, ensuring mechanical and dielectric reliability in subsea, marine and submersible service.
How are the concentric layers of VG 95218-29 (LWDC / PLWDC / PLWDC-C) arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Water-Blocked Conductors (4×2×0.75 mm²) — Fine-stranded tin-plated copper + black white-numbered special elastomer; (02) Isolated Pair Braid & Inner Covering — Tin-plated copper braid per pair + extruded elastomer inner covering (Type L / F); (03) Water-Blocking Fillers & Swelling Tapes — Longitudinal water-blocking fillers + lapped water-blocking tapes (61 bar rated); (04) Outer Tinned Copper Braid Shield — High-density tin-plated copper braid outer shield (Zt ≤ 15 mΩ/m); (05) Halogen-Free PUR / LSZH Outer Sheath — Black flame-retardant polyurethane HFS 100 (Type G–N) or LSZH elastomer (Type B–F).
What factory test certificates are supplied with VG 95218-29 (LWDC / PLWDC / PLWDC-C)?
Every production drum of VG 95218-29 (LWDC / PLWDC / PLWDC-C) undergoes routine conductor resistance/continuity, high-voltage dielectric and dimensional testing per German Military VG 95218-29 (Types B–N) 61 bar Outboard, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for VG 95218-29 (LWDC / PLWDC / PLWDC-C)

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

VG 95218-29 (LWDC / PLWDC / PLWDC-C) 61 bar Submarine Outboard Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp