Overhead conductors

Bare aluminum, steel-reinforced, high-temperature low-sag (HTLS) composite-core, XLPE-covered distribution and railway catenary overhead conductors built to IEC, ASTM, EN and AS/NZS standards for utility grids.

14 overhead conductors

Voltage
Standard
Sheath
Features

Bare aluminum & alloy conductors

Concentric-lay AAC (1350-H19), AAAC (6201-T81) and ACAR overhead distribution and transmission conductors.

3 cables
AAC — cable cross-section
AACAAC (All Aluminum Conductor) 1350-H19 Stranded Overhead Conductor
11–132 kV AC
Fixed
IECOther
11–132 kV AC, IEC, Other sheathFixed
AAAC — cable cross-section
AAACAAAC (All Aluminum Alloy Conductor) 6201-T81 Overhead Line Conductor
11–220 kV AC
Fixed
IECOther
11–220 kV AC, IEC, Other sheathFixed
ACAR — cable cross-section
ACARACAR 1350/6201 Overhead Conductor
11–230 kV AC
Fixed
IECOther
11–230 kV AC, IEC, Other sheathFixed

Steel & composite-core conductors

ACSR and high-temperature low-sag ACSS, ACCC, ACCR, GZTACSR and Invar-core ZTACIR grid conductors.

6 cables
ACCC /TW — cable cross-section
ACCC /TWCarbon-Composite Core Trapezoidal Aluminum Overhead Conductor
33–500 kV AC
Fixed
IECOther
33–500 kV AC, IEC, Other sheathFixed
ACCR — cable cross-section
ACCRAluminum Conductor Composite Reinforced Overhead Conductor
33–500 kV AC
Fixed
IECOther
33–500 kV AC, IEC, Other sheathFixed
ACSR — cable cross-section
ACSRACSR Overhead Transmission Conductor
11–500 kV AC
Fixed
IECOther
11–500 kV AC, IEC, Other sheathFixed
ACSS — cable cross-section
ACSSACSS High-Temperature Overhead Conductor
33–500 kV AC
Fixed
IECOther
33–500 kV AC, IEC, Other sheathFixed
GZTACSR — cable cross-section
GZTACSRGZTACSR Gap-Type Super-Thermal-Resistant Aluminum Alloy Overhead
33–500 kV AC
Fixed
IECOther
33–500 kV AC, IEC, Other sheathFixed
ZTACIR-AS — cable cross-section
ZTACIR-ASZTACIR / TACIR Super-Thermal-Resistant Zirconium-Aluminum Alloy
33–500 kV AC
Fixed
IECOther
33–500 kV AC, IEC, Other sheathFixed

Covered lines, ABC & catenary

XLPE covered conductors (CCT), aerial bundled cables (ABC), service drops and EN 50149 railway contact wires.

5 cables
TRIPLEX XLPE SERVICE DROP — cable cross-section
TRIPLEX XLPE SERVICE DROPICEA S-76-474 600 V Aluminum XLPE/ACSR Overhead Triplex
600 V
Fixed
ICEA / MSHAPE
600 V, ICEA / MSHA, PE sheathFixed
LV ABC AS-NZS 3560 — cable cross-section
LV ABC AS-NZS 3560AS/NZS 3560.1 0.6/1 kV X-90 XLPE Insulated Low-Voltage Aerial
0.6/1 kV
Fixed
AS/NZSPE
0.6/1 kV, AS/NZS, PE sheathFixed
Cu CATENARY MESSENGER — cable cross-section
Cu CATENARY MESSENGERHard-Drawn Copper Stranded Railway Overhead Catenary Messenger Wire
1.5–25 kV AC
Fixed
EN / HDOther
1.5–25 kV AC, EN / HD, Other sheathFixed
EN 50149 CONTACT WIRE — cable cross-section
EN 50149 Grooved Cu-ETP / CuAg / CuMg Railway Overhead TractionEN 50149 Grooved Cu-ETP / CuAg / CuMg Railway Overhead Traction
1.5–25 kV AC
Fixed
EN / HDOther
1.5–25 kV AC, EN / HD, Other sheathFixed
CCT — cable cross-section
CCTCCT 6.35/11 kV Covered Conductor Thick (XLPE) Overhead Distribution
6.35/11 kV – 19/33 kV
Fixed
AS/NZSPE
6.35/11 kV – 19/33 kV, AS/NZS, PE sheathFixed

Choosing overhead conductors

Four things decide most selections. Our engineers check the rest against your application.

Application and movement duty

  • Define whether the cable runs in a fixed tray, energy chain, festoon loop, reel or trailing route.
  • Match travel speed, bend radius and tensile load to the mechanical construction.
  • Select a support element or armour when the cable carries suspended weight or external crush loads.

Voltage class and core layout

  • Match the rated voltage U0/U to the supply system and earthing arrangement.
  • Specify phase cross-sections, protective earth, pilot cores or control pairs required by the machine.
  • Include copper braid, tape or semiconductive screens where EMC or electric-field control is needed.

Operating environment and sheath

  • Choose rubber, PUR, LSZH, PVC, fluoropolymer or silicone sheaths for the thermal and chemical exposure.
  • Verify oil, UV, water immersion, cold-flex or circuit-integrity ratings against site conditions.
  • Check outer diameter and gland compatibility at both terminations.

Standard and documentation

  • Confirm the governing standard family required by the project specification.
  • Verify conductor class, colour code or core numbering for the destination region.
  • Include operating duty and cable length in your enquiry so we can confirm the build.

Questions buyers ask

Not covered here? Send your drawing and an engineer replies within 2 business hours.

Ask on WhatsApp
How do I select the right cable assembly from this range?

Start by filtering the list by movement duty, voltage band and sheath material. Compare how each cable assembly is constructed—conductor flexibility, insulation compound, screening and outer jacket—against your machine's bending radius, travel speed and ambient temperature. Open the product page or datasheet to check core counts, cross-sections and outer diameters before sending your enquiry.

When should cable assemblies include metallic screening or armour?

Specify a copper braid or foil screen when cable assemblies run near variable-frequency drives, carry analogue or fieldbus signals, or require medium-voltage electric-field control. Choose steel wire braid or armour when the installation faces rock fall, crushing loads or high pulling tension in roadways, decks or subsea routes.

Which outer sheath compound suits harsh industrial environments?

Heavy-duty rubber (PCP or CPE) provides balanced mechanical toughness, weather resistance and thermal stability. Polyurethane (PUR) resists cuts, abrasion and mineral oils on fast-moving chains, reels and trolleys. Halogen-free LSZH compounds reduce smoke and acid gas in tunnels, ships and enclosed buildings, while fluoropolymers and silicone handle extreme heat.

What details should I include in an RFQ for cable assemblies?

Include the model designation or governing standard, rated voltage, number of cores and conductor cross-sections, along with the installation method, minimum bend radius, ambient temperature range and required delivery lengths. If you are replacing an existing cable on a machine, share the sheath marking so we can match the specification.

Engineering reference

Background on how overhead conductors are built, rated and specified.

Read the full reference

Cable assemblies cover industrial constructions engineered for reliable electrical transmission under defined mechanical, thermal and environmental stresses. Selecting the right build requires matching conductor stranding, insulation system, screening and outer sheath compound to the actual installation route rather than relying on nominal cross-section alone.

Across the TEBAOFLEX cable assemblies portfolio, models are grouped into functional families so engineers can filter by duty, voltage band, standard family and jacket compound. Each construction addresses a specific balance of flexibility, dielectric strength, electromagnetic compatibility and resistance to oil, water, UV radiation or flame propagation.

Before finalizing a specification, verify the governing national or international standard, operating voltage U0/U, ambient temperature range and minimum bending radius in fixed or moving duty. Where cables interface with connectors, glands or motor terminal boxes, check nominal outer diameter and screen termination geometry early.

When submitting an RFQ for cable assemblies, specify the model designation, core count and cross-sections, system voltage, installation method, environmental exposure and required drum or assembly lengths so our engineering team can confirm the exact construction and datasheet.

Compare cables